My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1130 SE EVERETT MALL WAY HOME GOODS 2023-06-22
>
Address Records
>
SE EVERETT MALL WAY
>
1130
>
HOME GOODS
>
1130 SE EVERETT MALL WAY HOME GOODS 2023-06-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2023 9:13:44 AM
Creation date
6/22/2023 9:12:02 AM
Metadata
Fields
Template:
Address Document
Street Name
SE EVERETT MALL WAY
Street Number
1130
Tenant Name
HOME GOODS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
50
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Lighting, Motor and Electrical Requirements List, pg 1 of 10 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2022 NEEA,All rights reserved <br /> • The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> Project: <br /> HOMEGOODS-2018 WSEC <br /> 1130-D SE Everett Mall Way <br /> Everett,WA 98208 <br /> Date: 2022-09-12 <br /> Applies Code Section Component Compliance Information Required In Permit Location in Building Department <br /> Documentation Documents Notes <br /> LIGHTING SCOPE <br /> C 103.1 Construction For a shell£core or tenant space(first build- <br /> documents-C,enert0 :.out)project,indicate if there is no lighting <br /> scope included in the project. <br /> YES C103.1 Construction For an alteration project,indicate if there is Elec Sheets <br /> documents-General no lighting scope included in the project. <br /> LIGHTING CONTROLS <br /> YES C405.2 Lighting controls, For all lighting fixtures,indicate lighting Elec Sheets <br /> general control method on plans for spaces and <br /> lighting zone(s)served,or exception taken <br /> C405.2, Luminaire level Indicate on plans all fixtures provided with <br /> Option 2 lighting controls LLLC in lieu of C405.2 lighting controls; <br /> (LLLC) provide description of control capabilities and <br /> performance parameters <br /> C405.2.5. Lighting in dwelling Indicate method of automatic control of all <br /> Item 3 units(dormitory, installed luminaires in dwelling units in <br /> C405.2.1.I hotel and all other buildings other than multifamily(occupancy <br /> C4052.3.1 than multifamily) or light reduction controls) <br /> C4052.5. Lighting in sleeping indicate method of automatic off control of <br /> Item 2 units .ill installed luminaires in sleeping units <br /> (vacancy or key card control):also refer to <br /> Receptacles-: <br /> YES C405.2.3 Manual controls Indicate on plans the method of manual Elec Sheets <br /> C405.2.3.1 lighting control,location of manual control <br /> C405.2.5 device and the area or specific application it <br /> serves <br /> YES C405.2.3.1 Manual interior light Indicate on plans which method of manual Elec Sheets <br /> C405.2.1.1 reduction controls 50%lighting load reduction is provided,or <br /> C405.2.4 indicate applicable exception <br /> YES C405.2.1 Method of automatic Indicate on plans the method of automatic Elec Sheets <br /> C405.2.2.1 shut-off control shut-off control during unoccupied periods <br /> C405.2.1, (occupancy sensor,time switch or digital <br /> Exception 3 timer switch)for all lighting zones <br /> NA C405.2.1 Occupant sensor Indicate on plans all luminaires that are <br /> controls controlled by occupant sensor controls; <br /> indicate controls are configured to turn <br /> luminaires 100%off when the space is <br /> unoccupied <br /> YES C405.2.1 Occupant sensor Indicate if occupant sensor controls are Elec Sheets <br /> C405.2.1.1 controls configured to be manual on or automatic on to <br /> not more than 50%power;indicate spaces <br /> eligible for exception that allows automatic on <br /> to 100%power <br /> Page 1/10 <br />
The URL can be used to link to this page
Your browser does not support the video tag.