Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 1 of 10 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2022 NEEA,All rights reserved <br /> • The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> Project: <br /> HOMEGOODS-2018 WSEC <br /> 1130-D SE Everett Mall Way <br /> Everett,WA 98208 <br /> Date: 2022-09-12 <br /> Applies Code Section Component Compliance Information Required In Permit Location in Building Department <br /> Documentation Documents Notes <br /> LIGHTING SCOPE <br /> C 103.1 Construction For a shell£core or tenant space(first build- <br /> documents-C,enert0 :.out)project,indicate if there is no lighting <br /> scope included in the project. <br /> YES C103.1 Construction For an alteration project,indicate if there is Elec Sheets <br /> documents-General no lighting scope included in the project. <br /> LIGHTING CONTROLS <br /> YES C405.2 Lighting controls, For all lighting fixtures,indicate lighting Elec Sheets <br /> general control method on plans for spaces and <br /> lighting zone(s)served,or exception taken <br /> C405.2, Luminaire level Indicate on plans all fixtures provided with <br /> Option 2 lighting controls LLLC in lieu of C405.2 lighting controls; <br /> (LLLC) provide description of control capabilities and <br /> performance parameters <br /> C405.2.5. Lighting in dwelling Indicate method of automatic control of all <br /> Item 3 units(dormitory, installed luminaires in dwelling units in <br /> C405.2.1.I hotel and all other buildings other than multifamily(occupancy <br /> C4052.3.1 than multifamily) or light reduction controls) <br /> C4052.5. Lighting in sleeping indicate method of automatic off control of <br /> Item 2 units .ill installed luminaires in sleeping units <br /> (vacancy or key card control):also refer to <br /> Receptacles-: <br /> YES C405.2.3 Manual controls Indicate on plans the method of manual Elec Sheets <br /> C405.2.3.1 lighting control,location of manual control <br /> C405.2.5 device and the area or specific application it <br /> serves <br /> YES C405.2.3.1 Manual interior light Indicate on plans which method of manual Elec Sheets <br /> C405.2.1.1 reduction controls 50%lighting load reduction is provided,or <br /> C405.2.4 indicate applicable exception <br /> YES C405.2.1 Method of automatic Indicate on plans the method of automatic Elec Sheets <br /> C405.2.2.1 shut-off control shut-off control during unoccupied periods <br /> C405.2.1, (occupancy sensor,time switch or digital <br /> Exception 3 timer switch)for all lighting zones <br /> NA C405.2.1 Occupant sensor Indicate on plans all luminaires that are <br /> controls controlled by occupant sensor controls; <br /> indicate controls are configured to turn <br /> luminaires 100%off when the space is <br /> unoccupied <br /> YES C405.2.1 Occupant sensor Indicate if occupant sensor controls are Elec Sheets <br /> C405.2.1.1 controls configured to be manual on or automatic on to <br /> not more than 50%power;indicate spaces <br /> eligible for exception that allows automatic on <br /> to 100%power <br /> Page 1/10 <br />