Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 5 of 10 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1— Administered by©2022 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C406.4 Enhanced digital To comply with additional efficiency credit, <br /> lighting controls indicate on plans that interior lighting fixtures <br /> are configured with all of the following <br /> control functions.as applicable: 1)Each <br /> fixture is individually addressed,or exception <br /> taken;2)Fixtures are configured for <br /> continuous dimming;3)No more than eight <br /> fixtures are controlled by a single daylight <br /> sensor;4)In enclosed and open office areas. <br /> illumination levels of overhead general area <br /> lighting is configured to be individually <br /> adjusted by occupants <br /> Include calculations that demonstrate the total <br /> lighting power of all interior lighting fixtures <br /> configured with enhanced lighting controls is <br /> no less than 90%of the total interior lighting <br /> power for the area the enhanced lighting <br /> controls credit is being applied to <br /> INTERIOR LIGHTING POWER&EFFICACY <br /> YES C405.4.1 Total connected Include all luminaires in interior lighting Elec sheets <br /> C405.4.2 interior lighting fixture schedule;indicate fixture types,lamps, <br /> power ballasts,and manufacturer's watts per fixture <br /> for the installed lamp <br /> NA Identify spaces eligible for lighting power <br /> exemption on plans and in WSEC interior <br /> lighting compliance reports;indicate the <br /> exception applied <br /> NA Identify lighting equipment eligible for <br /> lighting power exemption in fixture schedule <br /> and in WSEC interior lighting compliance <br /> reports;indicate the exception applied <br /> C405.1 Lighting in dwelling For all installed luminaires,include lamp type <br /> C405.1.1 units(multifamily) and number of lamps in lighting fixture <br /> schedule;for lamps that are not LED,T-8 or <br /> small diameter fluorescent,indicate efficacy <br /> of other lamp types is 65 lumens per watt or <br /> greater <br /> For all installed luminaires,indicate in <br /> lighting fixture schedule whether complying <br /> via lighting power density or by qualifying <br /> lamp type;if by lamp type,include number of <br /> lamps <br /> For all installed luminaires,indicate in <br /> lighting fixture schedule whether complying <br /> via lighting power density or by qualifying <br /> lamp type;if by lamp type,include number of <br /> lamps <br /> INTERIOR LIGHTING POWER CALCULATION-INDICATE COMPLIANCE PATH TAKEN <br /> YES C405.4.2.1 Building Area Demonstrate that total proposed wattage per Elec sheets <br /> Method building area does not exceed maximum <br /> allowed wattage per building area;identify <br /> locations of building areas on plans;provide <br /> WSEC exterior lighting compliance reports <br /> (Page 5/10 <br />