Laserfiche WebLink
Lighting, Motor and Electrical Requirements List, pg 4 of 10 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1 -- Administered by©2022 NEEA,All rights reserved <br /> The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> NA Indicate method of manual lighting control <br /> and applicable automatic lighting control <br /> YES C405.2.5, Means of egress Identify on plans egress fixtures that function Elec Sheets <br /> Item 5 lighting as both normal and emergency means of <br /> egress illumination <br /> YES Provide calculation of lighting power density Elec Sheets <br /> of total egress lighting <br /> NA If total egress lighting power density is greater <br /> than 0.02 W/sq.ft.,indicate on plans egress <br /> fixtures requiring automatic shut-off during <br /> unoccupied periods <br /> YES Indicate method of automatic shut-off control Elec Sheets <br /> YES C405.4.1 Lighting control of Indicate that exempt interior lighting Elec Sheets <br /> C405.4.2 exempt interior equipment and lighting located within spaces <br /> lighting that are eligible for a lighting power <br /> exemption are controlled independently from <br /> non-exempt and general area lighting <br /> NA C405.2.6 Exterior lighting For decorative exterior lighting,indicate on <br /> controls plans automatic daylight shut-off controls,or <br /> exception taken <br /> YES For exterior lighting that is not decorative, Elec Sheets <br /> indicate on plans automatic daylight or time- <br /> switch shut-off controls and setback controls; <br /> or indicate exception taken <br /> NA For lighting requiring setback controls, <br /> include control sequence that reduces lighting <br /> power by at least 30%between 12am-6am,or <br /> from 1 hour after closing to 1 hour before <br /> opening,or based upon motion sensor <br /> YES For building facade and landscape lighting, Elec Sheets <br /> indicate control sequence for shut-off control <br /> is based on dawn-to-dusk and business <br /> opening/closing schedule;indicate whether <br /> automatic or time switch controls will be <br /> provided for this function <br /> NA C405.5.2 Lighting control of Indicate that exempt exterior lighting and <br /> exempt exterior lighting located within exterior areas/surfaces <br /> lighting that eligible for a lighting power exemption <br /> are controlled independently from non- <br /> exempt exterior lighting <br /> NA C405.5.4 Exterior gas-fired Indicate ignition system is a method other <br /> lighting appliances then continuously burning pilot light <br /> YES C405.2.7 Area controls- Indicate location(s)of master control Elec sheets <br /> Master control switch(es)intended to control multiple <br /> switches and circuit independent switches;circuit breaker may not <br /> power limit be used as a master control switch <br /> YES Verify that no 20 amp circuit controlled by a Elec sheets <br /> single switch or automatic control is loaded <br /> beyond 80% <br /> ADDITIONAL EFFICIENCY CREDIT-ENHANCED INTERIOR LIGHTING CONTROLS <br /> Page 4/10 <br />