Lighting, Motor and Electrical Requirements List, pg 9 of 10 <br /> 2018 WSEC Requirements for Commercial Buildings including Group R2,R3&R4 over 3 stories&all R1-- Administered by©2022 NEEA,All rights reserved <br /> • The following information is necessary to check a permit application for compliance with the lighting systems,motors and electrical system requirements in the <br /> Washington State Energy Code,Commercial Provisions. <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> C405.6 Electrical Include electrical transformer schedule on <br /> transformers electrical plans;indicate transformer type, <br /> size.efficiency,or exception taken <br /> YES C405.11 Feeders and branch Provide documentation that demonstrates Elec Sheets <br /> circuits maximum voltage drop across feeders and <br /> branch circuits does not exceed 5% <br /> C405.7 Dwelling unit Indicate on electrical plans that each dwelling <br /> electrical enemy unit in Group R-2 has a separate electrical <br /> consumption energy meter <br /> C405.8 Electric motor Include all motors,including fractional hp <br /> efficiency motors.in electric motor schedule on <br /> electrical places;indicate motor type, <br /> horsepower.rpm,rated efficiency,or <br /> exception applied <br /> C405.9.t Elevator cabs For luminaires in each elevator cab,provide <br /> calculations that demonstrate average efficacy <br /> is not less than 35 lwnens per watt <br /> For elevators that do not have an integral air <br /> conditioning system,indicate rated watts per <br /> cfm for elevator cab ventilation fans do not <br /> exceed 0.33 watts per cfm <br /> Indicate automatic controls that de-energize <br /> lighting and ventilation fans when elevator is <br /> stopped and unoccupied for a period of 15 <br /> minutes or more <br /> C:405.9.2 Escalators and Indicate escalators comply with ASME <br /> moving walks A17.1/CSA 1344;automatic controls are <br /> configured to reduce operational speed to the <br /> minimum permitted when not in use <br /> C405.9.3 Regenerative drive Indicate all one-way down or reversible <br /> escalators are:provided with a variable <br /> frequency regenerative drive <br /> DOCUMENTATION AND SYSTEM REQUIREMENTS TO SUPPORT COMMISSIONING(CX) <br /> YES C408.4 Scope of electrical Indicate that all electrical systems Elec Sheets <br /> power and lighting (receptacles,transformers,motors,vertical <br /> systems and horizontal transportation)for which the <br /> commissioning WSEC requires control functions and/or <br /> configuration to perform specific functions <br /> are required to be commissioned <br /> YES Where total building lighting load is>20 kW, Elec Sheets <br /> or where total lighting load of luminaires <br /> requiring daylight sensing and/or occupancy <br /> control>10 kW,indicate that all automatic <br /> lighting control systems are required to be <br /> commissioned;or provide building lighting <br /> power calculation demonstrating eligibility for <br /> exception <br /> YES C405.13 Commissioning Indicate Cx requirements in plans and Elec Sheets <br /> C408.1.1 requirements in specifications for all applicable electrical and <br /> C408.1.2 construction lighting control systems per C408 <br /> C408.1.4.2 documents <br /> C103.6.3 <br /> Page 9/10 <br />