Laserfiche WebLink
MECHANICAL COMPLIANCE SUMMARY ..';, r: ;,a <br /> 2018 WSEC Compliance Forms for Commercial Buildings including Group R2,R3&R4 over 3 stories and all RI Administered by:©2022 NEEA,All rights reserved <br /> Project Title HOMEGOODS-2018 WSEC For Building Department Use: I Date: Sep 12,2022 <br /> Project Address 1130-D SE Everett Mall Way <br /> Project&Applicant Everett,WA 98208 <br /> Information Applicant Name Don Penn,P.E. 1 <br /> Applicant Phone 817-410-2858 <br /> Applicant Email dpceinfo@donpenn.com <br /> For questions about this report,contact WSEC Commercial Technical Support at 360-539-5300 or via email at com.techsupport@waenergycodes.com <br /> General Occupancy All Commercial General Building Use Type Retail,General Sales Building Cond.Floor Area 25,497 <br /> New Building Project Cond.Floor Area 25,497 <br /> Alteration <br /> General Project Types Alteration or Addition Mechanical Scope Multiple Zone Systems&Equipment Floors Above Grade 1 <br /> Mechanical Scope Compliance Method Compliance Method 1 -General <br /> Mechanical Project Description <br /> Economizer Equipment Efficiency <br /> Project DOAS Ventilation Higher Equipment <br /> Mechanical Scope Exception(s) ,, Compliance <br /> Mechanical Compliance Type Applied? Provided? Efficiency Option Applied. Verification <br /> Scope and Method <br /> Alteration Multiple Zone Systems& Yes Yes NA COMPLIES <br /> Equipment <br /> Additional Efficiency Higher equipment efficiency and fan FEG Dedicated outside air system(DOAS)option <br /> Credits Included(AEC) <br /> Does building include occupancy classifications requiring Yes Does project include DOAS equipment? Yes <br /> DOAS? <br /> Based on project scope do TSPR requirements apply? Yes Do all systems comply with Appendix D standard reference design or qualify for an exception to Yes <br /> 'TSPR? <br /> Scope&Space Conditioning AI TI:ItATION-MULTIPLE ZONE SYSTEMS&EQUIPMENT ,,,, ,„ �,��` •Compliance Verification COMPLIES <br /> ....... Boa „��\\\\� �`�*����t����owe�yec� <br /> Multiple Zone Air Systems Category-Air conditioner,unitary <br /> Air Systems Summary Information <br /> Supply Airflow Ventilation Ventilation Energy Recovery <br /> System ID Control Ventilation Standard CFM Air Source Paired with DOAS Ventilation energy recovery Efficiency CYO <br /> RTU-1,2 Variable air volume IMC Multiple Zones Ventilation 5,000 Integral Not-provided,not required <br /> RTU-3,4,5,7 Variable air volume IMC Multiple Zones Ventilation 3,000 Integral Not-provided,not required <br /> RTU-6 Variable air volume ASHRAE Standard 62.1 2,600 Integral Not-provided,not required <br /> Air Systems&Equipment-Cooling <br /> System/ Cooling System/Equip Type Specific Type Cooling Capacity AEC Efficiency i Econo Exception Combined Efficiency Proposed Cooling CE I Proposed Part PL Efficiency Compliance <br /> Equip ID per item(Btu/h) Multiplier Multiplier(FL&PL) Multiplier(AEC&Econo) Efficiency Units Load Efficiency Units Verification <br /> RTU-1,2 Air conditioner,air cooled Single package DX 170 1 0 1 14,000.0 SEER LEER COMPLIES <br /> RTU-6 Air conditioner,air cooled Single package DX 80 1 0 1 14,000.0 SEER LEER COMPLIES <br /> RTU-3,4,5,7 Air conditioner,air cooled Single package DX 94 1 0 1 14,000.0 SEER LEER COMPLIES <br /> Air Systems&Equipment-Heating <br /> AEC Proposed Heat <br /> System Heating System/Equip Heat Pump Heating Capacity Cooling Capacity HPH Proposed Low OSA LTH Efficiency Compliance <br /> /Equip ID Type Specific Type (Btu/h) (Btu/li) Efficiency Pump Units Temp Efficiency Units Verification <br /> Multiplier Heating Efficiency <br /> RTU-6 Furnace Warm air,gas fired I <br /> (AFUE) COMPLIES <br /> RTU- Furnace Warm air,gas fired I I COMPLIES <br />