Laserfiche WebLink
3,4,5,7 (AFUE) _ <br /> RTU-1,2 Furnace Warm air,gas fired <br /> (AFUE) 1 COMPLIES <br /> Air Terminal Equipment <br /> System ID _ Air Terminal Type Specific Type Quantity Cooling Capacity(Btu/h) Heating Capacity(Btu/h) Reheat Type <br /> RTU-3,4,5,7 Air terminal units I No reheat <br /> RTU-6 Air terminal units I No reheat <br /> RTU-1,2 Air terminal units 1 No reheat <br /> Air Systems&Equipment Details <br /> System ID Area(s)Served Location In Project Documents-Plan/Detail# <br /> RTU-I,2 SALES M1.0 <br /> Heating Section/Auxiliary Heating Type:Furnace Economizer Compliance Method:Economizer not required <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)A-Unitary Air Conditioners and Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating:Table C403.3.2(4)Warm Air Furnaces <br /> RTU-3,4,5,7 SALES/PROCESSING M1.0 <br /> Heating Section/Auxiliary Heating Type:Furnace Economizer Compliance Method:Air-side economizer provided <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)A-Unitary Air Conditioners and Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating:Table C403.3.2(4)Warm Air Furnaces <br /> RTU-6 LOUNGE/OFFICES I M1.0 <br /> Heating Section/Auxiliary Heating Type:Furnace Economizer Compliance Method:Economizer not required <br /> WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(1)A-Unitary Air Conditioners and Condensing Units <br /> WSEC Equip Efficiency Reference Table-Heating:Table C403.3.2(4)Warm Air Furnaces <br /> Multiple Zone Air Systems Category-Dedicated outside air system(DOAS) <br /> Air Systems Summary Information <br /> System ID Paired with other Systems/Equip Ventilation Airflow Ventilation Standard Ventilation CFM Ventilation energy recovery Energy Recovery <br /> Control Efficiency CA) <br /> DOAS-I Stand alone DOAS(not paired with other system) Variable air volume ASHRAE Standard 62.1 4,500 Yes per C403.6 DOAS 100 <br /> Air Systems&Equipment-Cooling <br /> System/ Cooling Capacity AEC Efficiency Econo Exception Combined Efficiency Proposed Cooling CE Proposed Part PL Efficiency Compliance <br /> Equip ID Cooling System/Equip Type Specific Type per item(Btu/h) Multi slier Multi Mier(FL&PL) Multiplier(AEC&Econo) EfficiencyUnits Load EfficiencyUnits Verification <br /> 1 I P <br /> DOAS-1 DX-DOAS,air cooled With energy recovery 208 I 0 1 5,200.0 ISMRE COMPLIES <br /> Air Systems&Equipment Details <br /> System ID Area(s)Served Location In Project Documents-Plan/Detail# <br /> DOAS-I SALES AREA M1.0 <br /> DOAS paired with heating&cooling systems:Stand alone DOAS(not paired with other system) <br /> Economizer Compliance Method:Air-side economizer provided WSEC Equip Efficiency Reference Table-Cooling:Table C403.3.2(l 1&12)DX-DOAS Units <br /> 2 / <br />