• <br /> 6. The flushing mechanisms for the toilets in the Type A units should be shown to be located <br /> on the wide side of the room (center controls may not comply).ANSI Section 1003.11.2.4.6 <br /> Response: See revised sheet A-0.2 under Accessibility code notes—Water closets in Type A <br /> Units. <br /> 7. The bath tubs in the Type A units should be shown with two grab bars on the back wall. <br /> ANSI Sections 607.4.2.1 & 1003.11.2.5.1 Response: See revised sheet A6.0 and A-6.1 All Type <br /> A units added second grab bar on the back wall of bathtubs with labels and dimensions. <br /> 8. The bath tubs in the Type A units should be shown with hand showers complying with <br /> ANSI Section 607.6.ANSI Section 1003.11.2.5.1 Response: See the revised code sheet A-0.2 <br /> under Accessibility code notes—Bathtub/Shower in Type A Units. <br /> 9. The cabinetry under the sink and clear work space should be (per ANSI Sections <br /> 1003.12.3.1 & 1003.12.4.1): <br /> a. Shown to be able to be removed without removal of the sink,Response: Notes and <br /> dimensions of maximum height of sink and work space have been added to B units. See new <br /> sheets A-6.2-A-6.6. A units are proposed to have open areas below work spaces and sinks, <br /> not removable cabinets. See revised notes on sheets A-6.8 and A-6.9. <br /> b. The floor finish should extend under the cabinetry,and Response: Note has been added <br /> to B type unit cabinetry. Response: Notes regarding floor finish have been added to B units. <br /> See new sheets A-6.2-A-6.6. A units are proposed to have open areas below work spaces <br /> and sinks,not removable cabinets. See revised notes on sheets A-6.8 and A-6.9. <br /> c. The walls behind the cabinetry should be finished. Response: Notes regarding finished <br /> walls have been added to B units. See new sheets A-6.2-A-6.6. A units are proposed to have <br /> open areas below work spaces and sinks,not removable cabinets. See revised notes on sheets <br /> A-6.8 and A-6.9. <br /> 10. Exposed pipes under the sinks and lavatories in the Type A units should be shown to be <br /> prevented from contact.ANSI Sections 1003.12.4.4 & 1003.11.2 Response: Current ADA <br /> toilet elevation drawings show removable cabinets. A note has been added indicating that if <br /> cabinets are removed ADA padding must be applied to exposed piping. See Sheets A-6.0 and <br /> A-6.01. <br /> 11.Details,clearances and elevations should be provided for the accessible toilet room on the <br /> 1s`floor.Section 1109.2 <br /> a.The walls and partitions should be shown in compliance with Section 1210.2.2 <br /> Response: See revised sheet A-6.1 with the interior design drawing of restroom plan and interior <br /> elevations. <br /> 12.Signage should be shown on the plans for the Van and Accessible parking spaces.Section <br /> 1111.1 Response: See revised sheets A-2.2 for location and detail of Accessible parking stall <br /> signage. <br />