• <br /> Mr. Art Skotdal <br /> Skotdal Real Estate <br /> Plan Check Number: B1906-031, First Building Review - Structural <br /> August 26, 2019 <br /> c. The building structural components (i.e., elevator shaft wall studs and supporting floor <br /> framing) that support the elevator system are included in the submittal drawings. <br /> Calculations substantiating the design of the structure to support the elevator loads <br /> concurrently with other loads (e.g., concurrent stud flexural and axial loading) shall be <br /> submitted for review. The calculations should include the evaluation of deflection limits per <br /> IBC Section 1607.9.1. The design shall consider concurrent multi-directional loading as <br /> determined by the elevator manufacturer. See IBC Sections 1604.2 and 1605. <br /> d. The connections between the elevator guide rails and the structural framing are typically the <br /> responsibility of the engineer-of-record for the building system. Calculations substantiating <br /> the connections to the structural framing shall be submitted for review. The design shall <br /> consider concurrent multi-directional loading as determined by the elevator manufacturer. <br /> The required locations and maximum spacing for the connection points should be specified <br /> in the structural drawings. See IBC Section 107.2.1 and 1604.4. <br /> e. The structural calculations shall be performing using the appropriate load combinations <br /> including live and seismic loading per IBC Section 1605. In addition, documentation shall be <br /> submitted verifying the nominal loads have been increased for impact effects per IBC <br /> Section 1607.9.1. <br /> f. The elevator shaft extends through five stories of wood-framed structure. Calculations <br /> substantiating that shrinkage of the structure will not adversely affect the performance of <br /> the elevator shall be submitted for review. Elevator rails should be evaluated for induced <br /> axial loads or provided with connections that allow for vertical differential movement. See <br /> IBC Section 2304.3.3. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Drew Martin, P.E., S.E. <br /> Associate Engineer/ Commercial Plans Examiner <br /> (425)257-8813 <br /> dmartin@everettwa.gov <br /> S:\B M a rti n\2019\B 1906-031_R 1-STR.d ocx <br /> O3200 Cedar Street © 425.257.8810 0 everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> ( E1of 12 <br />