My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r <br /> Mr. Art Skotdal <br /> Skotdal Real Estate <br /> Plan Check Number: B1906-031, First Building Review - Structural <br /> August 26, 2019 <br /> shall be provided per ACI 318-14 Section 18.10.6. Additional review comments may be <br /> provided pending review of the design. See IBC Section 1604.1. <br /> 38.The structural calculations do not include the design of the concrete diaphragms at Levels 1 and <br /> 2. Note that the Level 1 diaphragm must be evaluated to transfer the shear loads from the <br /> shear walls above to the basement walls through the diaphragm. Calculations substantiating <br /> the wall design shall be submitted for review. Additional review comments may be provided <br /> pending review of the design. See IBC Section 1604.1. <br /> 39.The structural calculations do not include the design of the wood diaphragm. Calculations <br /> substantiating the wall design shall be submitted for review. Collectors shall be designed per <br /> the requirements of ASCE 7-10 Section 12.10.2. Additional review comments may be provided <br /> pending review of the design. See IBC Sections 1604.1 and 1613.1. <br /> 40.The shear wall holdown design is provided in the wood shear wall portion of the structural <br /> calculations, and the resulting allowable stress design (ASD) level loads are provided in Detail <br /> 19/S1.30. The earthquake component of the uplift forces exceeds 20% of the total uplift (i.e., <br /> the earthquake force is 100% of uplift force). The earthquake component for connection of the <br /> holdowns to the Level 2 concrete slab shall be increased per the provisions of ACI 318-14 <br /> Section 17.2.3.4.3. Calculations substantiating the holdown design load for the attachment to <br /> the slab shall be submitted for review. The design load shall be determined per ASCE 7-10 <br /> Section 12.4.3.2 Equation 7 including the vertical seismic load effect per Section 12.4.2.2. The <br /> factored-level (LRFD) design loads shall be specified in Detail 19/S1.30. See IBC Sections <br /> 1604.10, 1613.1, and 1901.2. <br /> 41.The design for the shear wall sill plate anchor bolts has not been provided in the structural <br /> calculations. The earthquake component of the shear forces exceeds 20% of the total shear <br /> (i.e., the earthquake force is 100% of shear force). The earthquake component shall be <br /> increased per the provisions of ACI 318-14 Section 17.2.3.5.3. Calculations substantiating the <br /> anchor bolt design shall be submitted for review. The design load shall be determined per <br /> ASCE 7-10 Section 12.4.3.2 Equation 7. See IBC Sections 1604.10, 1613.1, and 1901.2. <br /> Miscellaneous: <br /> 42.The project includes an elevator at Grid E/4. Connections for the elevator system to the wood- <br /> frame portion of the shaft are provide in Details 11/S9.01 through 14/S9.01. The following <br /> comments should be addressed: <br /> a. The design loads for the elevator system, including impact loading, should be specified in <br /> Section 01003 "Design Live Loads/ Data"of the Structural Notes on Sheet S1.01. At a <br /> minimum, estimated design loads shall be specified for the design, and verified when the <br /> elevator design drawings are submitted for review. See IBC Sections 1603.1.8 and <br /> 1607.9.1. <br /> b. Details for the connection of the elevator system to the concrete portion of the structure <br /> shall be included in the structural drawings. See IBC Section 1603.1. <br /> 0 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Page 11 of 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.