My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 • <br /> , <br /> Mr. Art Skotdal <br /> Skotdal Real Estate <br /> Plan Check Number: B1906-031, Second Building Review- Structural <br /> October 18, 2019 <br /> 16. No additional comment. <br /> 17. No additional comment. <br /> 18.This comment has not been completely addressed. The original comment addressed the design <br /> of the prefabricated metal balconies around the building perimeter on Sheets S2.09 and S2.11 <br /> through S2.14 show. See IBC Sections 107.2.1, 1603.1, 1604.1, 1604.4, 1609.1, and 1613.1. <br /> The following comments shall be addressed: <br /> a. No additional comment. <br /> b. Details 1/S9.02 and 2/S9.02 specify support for the balconies using tension rods connected <br /> back to the building framing. The framing has been designed to support approximately <br /> one-half of the balcony loads, with attachment points located at the free-end of the <br /> balconies. The details shall specify a minimum dimension of four feet from the building face <br /> for the rod attachment point. Otherwise, the rods and supporting building framing shall be <br /> designed for the additional loading based on the maximum loads that can occur for the <br /> worst-case positioning of the rod connections to the balconies <br /> c. The structural calculations consider an effective rod spacing of 3.5 feet (i.e., one-half of a <br /> seven-foot wide balcony). This calculation has been leveraged for the support of the <br /> continuous balconies along the west side of the building. Detail 2/S9.02 shall specify braces <br /> at a maximum spacing of 3.5 feet. Note that the building wall does not provide posts a this <br /> spacing due to openings (i.e., doors and windows). Alternatively, the design shall be <br /> revised to provide a support system compatible with the proposed balconies. It is further <br /> noted that the braces may conflict with the use of the balcony and create tripping hazards. <br /> The structural design should be coordinated with the architectural design. <br /> d. Continuing with the previous comment, the design for the continuous balconies along the <br /> west side of the building may be revised. If the design is changed to a cantilever-type <br /> system, the supporting framing shall be designed for the maximum net upward force on the <br /> balconies from wind and seismic. Wind load shall be per ASCE 7-10 Chapter 30. Seismic <br /> load shall equal to 20% of the dead load per ASCE 7-10 Section 12.4.4. <br /> 19.This comment has not been addressed. The Level PO and P1 slabs have areas that are not <br /> clearly defined in the construction drawings, and do not appear to be substantiated in the <br /> structural calculations. The presence of the floor areas, construction of the floors (e.g., post- <br /> tensioned or mild reinforcement, non-concrete construction) and the supports for the areas <br /> cannot be clearly determined. See IBC Sections 107.2.1, 1603.1, and 1604.1. The following <br /> areas shall be addressed: <br /> a. Grid F-G/3/4 on Sheet S2.01. No apparent revision has been made to this area. Design for <br /> the area is not included in the structural calculations. <br /> b. Grid F-G/4-5 on Sheet S2.01. No apparent revision has been made to this area. Design for <br /> the area is not included in the structural calculations. <br /> c. Grid E-F.4/5-6.1 on Sheet S2.01. No apparent revision has been made to this area. Design <br /> for the area is not included in the structural calculations. <br /> d. Grid G-J/4-5 on Sheet S2.03 has been revised to a mildly-reinforced concrete slab. The <br /> following comments shall be addressed: <br /> O3200 Cedar Street © 425.257.8810 �,�,� everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax ��� everettwa.gov/permits <br /> C'ag...e"'6 of 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.