• <br /> •Plan Check Number B1906-031 <br /> 2721 Wetmore Avenue lb <br /> Response to concrete comments from Second Building Review, October 18, 2019 <br /> Structural: <br /> Item 2 <br /> 2a. The question regarding design pressures for below grade perimeter walls was discussed with Matt <br /> Miller,Associated Earth Sciences. Matt said that the choice of design soil pressure(35 pcf active or at- <br /> rest 55 pcf or apparent with multiple supports 25H)is dependent on the location, installation conditions <br /> and is the decision of the engineer of record. Note that installation of shotcrete wall against a flexible soil <br /> nail wall is considered to be flexible. <br /> 2b and 2c. Structural calculations considering at-rest pressures was previously submitted in <br /> supplemental calculations included consideration of traffic surcharges. Reference attached <br /> supplemental structural calculations for supplemental calculations considering multiple levels of support <br /> and surcharges from North and South building perimeter walls. <br /> Item 3 <br /> 3a and 3b. The Structural Notes on Sheet S1.01 Section 01005 have been revised to update the shop <br /> drawing and deferred submittal requirements for this project. Note that the first line of Section 01005 <br /> includes the requirement that all submittals shall be provided to the structural engineer for approval. <br /> Item 4 <br /> Structural Notes Sheet S1.01 Section 03101 is revised to list the minimum reinforcement required for <br /> various wall thicknesses. Where details specify a greater amount of reinforcement, it shall control for <br /> that specific location. Wall sections now refer to this schedule. The schedule includes 6"and 14"walls <br /> as for this project. <br /> Item 5 <br /> RE wall sections for wall reinforcement requirements which reference the schedule noted in response to <br /> Item 4.Typical Detail 16/S6.00 specifies added wall reinforcement at all wall openings and adjusts bar <br /> size and spacing short wall piers between openings. At piers a tighter spacing and/or smaller bar size is <br /> specified to meet minimum spacing requirements while still meeting require areas. Diagonal bars are <br /> added crack arrest bars. Supplemental calculations are provided confirming wall reinforcement and <br /> confirm that concrete header beams do not require special reinforcement. <br /> Item 7 <br /> 7a. Noted. The sheets have been deleted. <br /> 7b. RE revised plans, details and supplemental structural calculations for transfer beams. Sheet S3.00 <br /> is updated to clarify reinforcement at the transfer beam locations. <br /> 7c. RE response to Item 5. <br /> 7d. Wall elevations and sections have been updated. <br /> 7e. Sheet S3.02 is deleted from the project. The wall reinforcement is now covered in S1.01. RE <br /> response to Item 4. <br /> 7f and 7g. Sections have been updated. <br /> 7h and 7i. Column locations have been coordinated with the architect. Confirming, all columns align. <br /> Where columns rotate, RE details 3 and 4/S6.01. RE supplemental calculations. <br /> Item 8 <br /> 8a and 8b. Typical wall thickness is 10 inches and Sheet S2.00 is updated. All interior walls are <br /> marked with thickness. Reinforcement is covered in the Structural Notes RE Item 4 above, and per <br /> sections. Wall thickness is coordinated with architectural to agree with structural requirements. <br /> Item 11 <br /> Roof Penthouse. The response to all wood frame items is forthcoming in a separate response and <br /> submittal. <br /> Page 12 r i <br />