My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> •Plan Check Number B1906-031 <br /> 2721 Wetmore Avenue lb <br /> Response to concrete comments from Second Building Review, October 18, 2019 <br /> Structural: <br /> Item 2 <br /> 2a. The question regarding design pressures for below grade perimeter walls was discussed with Matt <br /> Miller,Associated Earth Sciences. Matt said that the choice of design soil pressure(35 pcf active or at- <br /> rest 55 pcf or apparent with multiple supports 25H)is dependent on the location, installation conditions <br /> and is the decision of the engineer of record. Note that installation of shotcrete wall against a flexible soil <br /> nail wall is considered to be flexible. <br /> 2b and 2c. Structural calculations considering at-rest pressures was previously submitted in <br /> supplemental calculations included consideration of traffic surcharges. Reference attached <br /> supplemental structural calculations for supplemental calculations considering multiple levels of support <br /> and surcharges from North and South building perimeter walls. <br /> Item 3 <br /> 3a and 3b. The Structural Notes on Sheet S1.01 Section 01005 have been revised to update the shop <br /> drawing and deferred submittal requirements for this project. Note that the first line of Section 01005 <br /> includes the requirement that all submittals shall be provided to the structural engineer for approval. <br /> Item 4 <br /> Structural Notes Sheet S1.01 Section 03101 is revised to list the minimum reinforcement required for <br /> various wall thicknesses. Where details specify a greater amount of reinforcement, it shall control for <br /> that specific location. Wall sections now refer to this schedule. The schedule includes 6"and 14"walls <br /> as for this project. <br /> Item 5 <br /> RE wall sections for wall reinforcement requirements which reference the schedule noted in response to <br /> Item 4.Typical Detail 16/S6.00 specifies added wall reinforcement at all wall openings and adjusts bar <br /> size and spacing short wall piers between openings. At piers a tighter spacing and/or smaller bar size is <br /> specified to meet minimum spacing requirements while still meeting require areas. Diagonal bars are <br /> added crack arrest bars. Supplemental calculations are provided confirming wall reinforcement and <br /> confirm that concrete header beams do not require special reinforcement. <br /> Item 7 <br /> 7a. Noted. The sheets have been deleted. <br /> 7b. RE revised plans, details and supplemental structural calculations for transfer beams. Sheet S3.00 <br /> is updated to clarify reinforcement at the transfer beam locations. <br /> 7c. RE response to Item 5. <br /> 7d. Wall elevations and sections have been updated. <br /> 7e. Sheet S3.02 is deleted from the project. The wall reinforcement is now covered in S1.01. RE <br /> response to Item 4. <br /> 7f and 7g. Sections have been updated. <br /> 7h and 7i. Column locations have been coordinated with the architect. Confirming, all columns align. <br /> Where columns rotate, RE details 3 and 4/S6.01. RE supplemental calculations. <br /> Item 8 <br /> 8a and 8b. Typical wall thickness is 10 inches and Sheet S2.00 is updated. All interior walls are <br /> marked with thickness. Reinforcement is covered in the Structural Notes RE Item 4 above, and per <br /> sections. Wall thickness is coordinated with architectural to agree with structural requirements. <br /> Item 11 <br /> Roof Penthouse. The response to all wood frame items is forthcoming in a separate response and <br /> submittal. <br /> Page 12 r i <br />
The URL can be used to link to this page
Your browser does not support the video tag.