My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
/ l'. <br /> Building Permit Plans Checklist, pg. 3 ENV—CHK <br /> 2015 WSEC Compliance Forms for Commercial Buildings including R2,R3,&R4 over 3 stones and all Ri Revised Oct 2017 <br /> Project Title: Marquee Apartments Date 03/14/2019 <br /> Applicability Code Location in Building <br /> (yes,no,na) Section Component Compliance information required in permit documents Documents Department Notes <br /> In single story buildings,provide list of enclosed areas that exceed 2,500 <br /> sf;for each space identify the space use.floor area.floor to ceiling height, <br /> whether skylights are installed,and any exception taken; <br /> Provide calculations for percentage of conditioned floor area located within <br /> Spaces in single a daylight zone including skylight and eligible sidelight daylight zones; <br /> C402.4.2 story buildings <br /> requiring skylights Provide calculations for percentage of skylight area in each space over <br /> 2,500 sf,OR; <br /> Provide calculations for skylight effective aperture(Equation C4-5)for <br /> each space over 2,500 sf; <br /> Indicate haze factor of skylight glazing material or diffuser <br /> ADDITIONAL EFFICIENCY PACKAGE OPTION -ENHANCED ENVELOPE PERFORMANCE <br /> To comply with additional efficiency package option,demonstrate <br /> C406.8 Enhanced envelope envelope insulation compliance via component performance;provide ENV- <br /> performance UA/ENV-SHGC compliance forms;verify that building total UA is 15% <br /> lower than the Code target UA <br /> AIR LEAKAGE <br /> Identify location and provide diagram of continuous air barrier in plans and <br /> Air barrier sections; <br /> C402.5.1.1 construction and Provide details for all joints,transitions in materials,penetrations in air <br /> sealing barrier and note method of sealing(caulked,gasketed,or other approved <br /> method) <br /> Indicate that room(s)containing non-direct vent appliances is isolated from <br /> Rooms containing conditioned space by the thermal envelope with a sealed air barrier, <br /> open combustion including doorway gasketing and sealing around ductwork and piping <br /> C402.5.3 fuel burning <br /> appliances used for penetrations; -- - <br /> space conditioning Indicate insulation provided in wall,floor and ceiling of the room envelope, <br /> and insulation required on combustion air ductwork <br /> Access openings Indicate locations of all access openings and doors to shafts,chutes, <br /> C402.5.4 and doors to shafts, stairways and elevators; <br /> chutes,stairways Indicate method of gasketing,weatherstripping and sealing of these <br /> and doors openings <br /> Indicate locations of all stairway enclosure,elevator shaft and building <br /> C402.5.5 Outdoor air intakes, pressurization relief openings,outside air intakes and exhaust openings; <br /> C403.2.4,3 exhausts and relief Note in envelope plans that all relief,outside air intake and exhaust <br /> openings openings shall be provided with dampers in accordance with Mechanical <br /> Section C403.2.4.3 <br /> Indicate method of sealing between light fixture housing and wall or ceiling; <br /> Recessed lighting in <br /> C402.5.8 building envelope Note in envelope plans that all recessed lighting fixtures shall be IC rated <br /> and have an air leakage rating not greater than 2 cfm per ASTM E283 test; <br /> include these requirements in lighting fixture schedules <br /> C402.5.6 Loading dock seals Indicate weather seal at cargo and loading dock doors <br /> Indicate locations and dimensions of vestibules and air curtains; <br /> Indicate exception and criteria utilized for all building entrances and exits <br /> C402.5.7 Vestibules <br /> that do not have a vestibule or air curtain; <br /> Indicate required performance for air curtains installed per exception 7; <br /> For unconditioned vestibules,indicate which envelope assembly(interior <br /> or exterior)complies with the requirements for a conditioned space <br /> Indicate on plans the location of air barrier boundaries and area <br /> calculations on all six sides of the air barrier; <br /> Indicate air barrier test method in accordance with ASTM E779 or <br /> approved equivalent; <br /> Indicate required maximum leakage rate for compliance. <br /> C103.2 Building air leakage <br /> C402.5.1.2 test Include the following requirements in project documents:(1)Submit air <br /> barrier test report to jurisdiction once test is completed;(2)If test results <br /> exceed 0.40 cfm/ft2(1.5 L/s*m2)at 0.3 in.wg(75 Pa),then visually inspect <br /> air barrier and seal noted sources of leakage;(3)Submit a follow-up report <br /> to jurisdiction noting corrective measures taken; (4)Include air barrier test <br /> report in compliance documentation provided to building owner. <br />
The URL can be used to link to this page
Your browser does not support the video tag.