Laserfiche WebLink
S 0 <br /> .62/-; <br /> 3. Electric vehicle charging locations and infrastructure requirements should be shown on <br /> the plans. Section 427 <br /> 4. The locations of the smoke alarms (smoke detectors) within the dwelling units should be <br /> shown on the plans. Section 907.2.11.2 <br /> 5. The locations of the carbon monoxide detectors within the dwelling units should be shown <br /> on the plans. Section 915.1 <br /> 6. Emergency responder radio coverage is required within the building (and may prove <br /> challenging in the basement garage area). Compliance should be coordinated with the fire <br /> marshal's office. Section 916.1 <br /> 7. There are parts of the structure along Wetmore that are constructed in the right-of-way. <br /> We will leave this acceptance to the Public Works Director (and will be addressed in the <br /> PW review). <br /> 8. Local exhaust and whole house ventilation requirements should be detailed on the plans. <br /> IMC Section 403.8 <br /> 9. Either natural or mechanical ventilation should be provided for the alcove and den spaces <br /> — irrespective of openable doors that close off the space from adjacent areas that are <br /> provided with natural ventilation. IMC Section 403.8 <br /> a. The amounts of ventilation required and provided for each dwelling unit should be <br /> shown on the plans. <br /> 10. All safety glazing should be specifically identified on the plans/schedule. Section 2406.1 <br /> 11.The sales prohibition covenant must be on file with Snohomish County prior to issuance <br /> of the building permit. Please forward a copy of the recorded document when completed. <br /> RCW 64.55 <br /> Construction <br /> 1. The parapet details on the A-8.xx sheets should be completed (tags show <br /> #DrgID/#LayID). Fire rated parapets are required per Section 705.11 on several exterior <br /> walls due to distances to property lines (or Exception 4 may be employed). <br /> 2. Is the listing for wall type W-5/A-9.1 WP 3371 or WP 3380 (we are not on the most current <br /> GA Manual)? Please provide a cut sheet. <br /> 3. The printing for wall type M-1-4/A-9.0 was cut off on the top. The detail, listing and fire- <br /> resistance will be reviewed on the re-check. <br /> 4. Is the listing for roof/ceiling type FW-5/A-9.1 FC 5530 as shown? If so, please provide a <br /> cut sheet. <br /> O 3200 Cedar Street © 425.257.8810 O tlee@everettwa.gov <br /> Everett, WA 98201 425.257.8857 fax everettwa.gov <br />