My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
>
Address Records
>
WETMORE AVE
>
2721
>
MARQUEE APARTMENTS
>
2721 WETMORE AVE MARQUEE APARTMENTS 2023-06-28
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/28/2023 11:11:14 AM
Creation date
6/22/2023 9:57:45 AM
Metadata
Fields
Template:
Address Document
Street Name
WETMORE AVE
Street Number
2721
Tenant Name
MARQUEE APARTMENTS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
544
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> JOHNSONOAKLIEFARCHITECTURE & PLANNING LLC Q/v Z/ � <br /> August 7,2019 <br /> Tony Lee <br /> City of Everett <br /> Public Works Department <br /> 3200 Cedar Street <br /> Everett,WA 98201 <br /> Re: Plan Check No: B 1906-031 <br /> Tony, <br /> Below are our responses to your review comments dated August 05,2019. The numbering sequence <br /> matches your own and revisions have been indicated with clouds on the attached documents. <br /> NON-STRUCTURAL <br /> General <br /> 1. Per our conversation,the type of construction for the upper building has changed from <br /> IIIA to VA.This review is based on that revision.Section 504.4.1 <br /> a. The allowable area calculation should be shown on the plans for the type V-A <br /> building.Section 506.2.3 Response: The construction type has been revised. See <br /> "Building Code—Construction Types Sheet A0.2 <br /> b. The building height is shown as 70.85' per the elevations and definition in Section <br /> 202.Table 503.4 provides for a maximum height of 70' for Group R Occupancies of <br /> Type VA Construction.It is our opinion that the .85' discrepancy is not significant <br /> YP P P Y g <br /> enough of a deviation to warrant either a re-design or a change to a higher fire- <br /> resistive type of construction.Section 510.2 Response: Building Height Calculations <br /> have been revised. See sheet A-0.2, Building Code—Maximum Building Heights <br /> c. The stairs are required to be pressurized for the building (and special inspected), <br /> however the elevator is not per the building code... unless I am missing something... <br /> (as stated in Note#24 on Sheet A-0.2). Response: A note requiring stair pressurization <br /> has been added. See sheet A0.2 Building Code—Mechanical Notes. The elevator is <br /> being pressurized per Washington IBC section 909.21 (pressurization in lieu of enclosed <br /> elevator lobbies) <br /> d. Legally required standby power should be provided for the stairway pressurization <br /> system-the method of compliance should be clarified on the plans (2ndary tap, <br /> generator,etc).Response: A note has been added indicating a secondary tap. See sheet <br /> A-0.2 Building Code—Electrical Notes. <br /> e. The one-hour exterior wall listings will be review upon re-submission.Response: <br /> Exterior wall types have been revised to one hour. See revised wall types Sheet A-9.0 <br /> 2. The plans should note that mechanical ventilation for the garage will be provided.Section <br /> 406.6.2 Response: See revised sheets A-2.0,A-2.1 and A-2.2 where it is noted that mechanical <br /> 2124 Third Avenue Suite 200,Seattle,WA 98121 I 206-448-7580 I f 206-448-8977 I j-arch.coin <br />
The URL can be used to link to this page
Your browser does not support the video tag.