• g <br /> ventilation is to be provided at the garage. Mechanical engineering and permitting is to be <br /> Bidder Design. <br /> 3. Electric vehicle charging locations and infrastructure requirements should be shown on the <br /> plans.Section 427 Response: EV stalls have been added. See revised parking calculation sheet <br /> A 0.1 and first floor plan sheet A 2.2. <br /> 4. The locations of the smoke alarms (smoke detectors within the dwelling units should be <br /> shown on the plans.Section 907.2.11.2 Response: See revised sheets A-5.0 through A-5.7 for <br /> locations of smoke detectors. Note has been added to indicate smoke detectors are to be hard- <br /> wired with battery backup. <br /> 5. The locations of the carbon monoxide detectors within the dwelling units should be shown <br /> on the plans.Section 915.1 Response: See revised sheets A-5.0 through A-5.7 for locations of <br /> carbon monoxide detectors. Note has been added to indicate carbon monoxide detectors are to <br /> be hard-wired with battery backup. <br /> 6. Emergency responder radio coverage is required within the building (and may prove <br /> challenging in the basement garage area).Compliance should be coordinated with the fire <br /> marshal's office.Section 916.1 Response: See revised sheet A-0.2 under"Building Code <br /> Notes" section. Compliance to be in accordance with IBC Section 918.1 <br /> 7. There are parts of the structure along Wetmore that are constructed in the right-of-way. <br /> We will leave this acceptance to the Public Works Director(and will be addressed in the <br /> PW review). Response: We will address any comments from Public Works with a separate <br /> response letter. <br /> 8. Local exhaust and whole house ventilation requirements should be detailed on the plans. <br /> IMC Section 403.8 Response: See revised sheets A-5.0 through A-5.7 for locations of exhaust <br /> and ventilation fixtures. Per IBC Section 403.3,the required cubic feet per minute (CFM) <br /> ventilation is 100 CFM for kitchens and 50 CFM for bathrooms. <br /> 9. Either natural or mechanical ventilation should be provided for the alcove and den <br /> spaces—irrespective of openable doors that close off the space from adjacent areas that are <br /> provided with natural ventilation.IMC Section 403.8 Response: See revised sheets A-5.0 <br /> through A-5.7 for unobstructed opening size and locations at alcoves and dens. Per IMC Section <br /> 402.3,unobstructed openings are to be a minimum of 8% the size of the floor area of the room. <br /> a. The amounts of ventilation required and provided for each dwelling unit should be <br /> shown on the plans.Response: See revised sheets A-5.0 through A-5.7 for natural <br /> ventilation size requirements for each unit. Per IMC Section 402.2,trickle vents shall be <br /> provided in window frames to allow for a minimum of 4 square inches open area per 10 <br /> CFM of required mechanical ventilation. <br /> 10.All safety glazing should be specifically identified on the plans/schedule.Section 2406.1 <br /> Response: See revised sheet A-3.5.The symbol "S" is added to panes that will be safety glazing. <br />