Laserfiche WebLink
Subsurface Exploration, Geologic Hazard,and <br /> 2721 Wetmore Preliminary Geotechnical Engineering Report <br /> Everett, Washington Seismic Hazards and Mitigations <br /> 5.3 Ground Motion <br /> Based on the site stratigraphy and our visual reconnaissance of the site, it is our opinion that <br /> any earthquake damage to the proposed structure, when founded on suitable bearing strata in <br /> accordance with the recommendations contained herein, will likely be caused by the intensity <br /> and acceleration associated with the event. Structural design of the building should follow 2015 <br /> IBC standards using Site Class "C" as defined in Table 20.3-1 of American Society of Civil <br /> Engineers (ASCE) 7 - Minimum Design Loads for Buildings and Other Structures. However, a <br /> site-specific study could be performed to refine or verify the site class if needed. <br /> May 28,2019 ASSOCIATED EARTH SCIENCES,INC. <br /> Pa e7 <br /> FSM/Id-190168E001-2-Projects\20190168\KE\WP g <br />