• <br /> See the revised Sheet A1.3 calling out new hangers (refer to Sheet S1.0) to the new beam per <br /> plan. See the new detail 1 on S2.0 for the new ceiling rafters to the new roof rafters. <br /> 6. See Section on Sheet A1.3. New 2x8 roof rafters are shown extending beyond the new roof <br /> beam. It is unclear the span lengths of the new roof joists and the connections. If rafters are <br /> extending back to the existing ridge beam, then the ridge beam should be evaluated for the <br /> additional dead load. Also, plans should show how rafters are connected to the new wall top <br /> plate. <br /> See the structural calculations showing that the replaced roof rafters are designed to place <br /> no new load onto the existing ridge beam. <br /> 7. Plans should show a fastening schedule. See Section R602.3 <br /> See the general notes on Sheet S1.0 for the fastening requirements/schedule for the job. <br /> 8. Section on Sheet A1.3 should show how the existing rafter is connected to new dormer wall. <br /> See the new detail 1 on S2.0 for how the new roof rafters attach to the new dormer wall. <br /> 9. Plans should specify how the multi-member beams are connected. For example, the new roof <br /> beam (2) 1 3/4"x 11 7/8" LVL and the new (3) 1 3/4"x 7 1/4"floor beam. <br /> See the general notes on Sheet S1.0 for how multi-ply members should be connected. <br /> 10. See Structural Calculations Page 1. Floor Beam B2 appears to not include the entire supporting <br /> load. Section 3 on Sheet A1.3 shows floor joists spanning perpendicular to the Floor Beam B2; <br /> however, Structural Sketches (Upper Floor Framing Plan) show floor joists spanning parallel to <br /> the Floor Beam B2. The direction of the existing floor joists is unclear. If joists are perpendicular <br /> to the new floor beam, then plans should show the connection of existing floor joist to new <br /> beam. Update Structural Calculations as necessary. <br /> See the updated plans with the Section now correctly showing the existing floor joists spanning <br /> parallel to the new beam B2. The beam B2 has been re-calculated for the new roof rafter <br /> 11. See Structural Calculations Upper Floor Framing Plan sketch. Framing plan should show how the <br /> new floor beam is connected to the (2) 2x8. <br /> See the updated plans with the new hanger callout to support the new LVL beam. <br /> 12. Plans and Structural Calculations should show a continuous load path down to the foundation <br />