, 7 of 31 <br /> PROJECT NO. SHEET NO. <br /> S210630-4XR <br /> PROJECT 1434 GRAND AVE, EVERETT, WA 98201 <br /> LONGITUDE SUBJECT Foundation Stabilization/Jacking <br /> ONE TWENTY FY 07/21/2021 <br /> ENGINEERING&DESIGN BY DATE <br /> Ideal Foundation Systems 2-7/a`'0 Helical Pile(0.203-inch wall thickness)-Soil Capacity per ESR-3750 <br /> DIGGA 101 Drive Torque Corretanbn Factor, K, Uhimate Axial Compressive Allowable Pool Compress m <br /> Head Torque, T Compression Capecay, P.=K,•T Capacity, P.=0.5*P <br /> Pressure rfr`ibs) <br /> (Psi) <br /> (n`) kips' tool <br /> 500 1,740 9 15.7 7;9 <br /> 600 2,088; 9 18:8 9.4 <br /> 700 2,436 9 21.9 11_0 <br /> 800 2,784 9 25.1 125 <br /> 900 3,132 9 28.2 14.3 <br /> 1000 3.480 9 31.3 15.7 <br /> 1100 3.828 9 34 5 17.2 <br /> 1200 4,176 76 9 37.E 18.8 <br /> 1300 4.524 9 40 7 _ 20.4 <br /> 1400 4,872 9 43.8 21.9 <br /> 1500 5,220 9 47_0 23.5 <br /> 1600 5,568 9 50.1 251 <br /> 3700 5,915 9 53.2 26:6 <br /> 1800 5,264 9 56.4 28.2 <br /> MAX 1900 6.612 9 59.5 29.11 'See Note vill <br /> 2000 6,960 9 62.6 31.3 <br /> 2300 7,308 9 65.8 32.9 <br /> 2200 7,556 9 68_9 34.5 <br /> 2300 8,000 9 72-,0 360 *See Note It <br /> i.)DIGGA 10K Drive Head differential pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> ii.)Per Table 5A of ESR-3750 and Ideal Manufacturing Inc.,the maximum installation torque rating of a 2-7/8"0 helical pile(0,203-inch wall thickness)is 8;300 <br /> ft"ibs.Final installation torque shall not exceed this value. <br /> iii.)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in the structural <br /> package,but shall not exceed the maximum allowable capacity for any part of the pile assembly. <br /> iv.)Refer to ESR-3750 and Ideal Manufacturing,Inc.documents for additional information and requirements. <br /> v.)Definitions per ESR-3750: <br /> T=Final Installation torque in ft*lbs;the last torque reading taken during pile installation,using,for example,the torque reading <br /> instruments connected to the installation equipment. <br /> K,=Torque correlation factor per ESR-3750 <br /> P„=Ultimate axial compressive capacity(in kips)of helical pile <br /> Po=Allowable axial compressive capacity(in kips)of helical pile <br /> vi.)For torque readings between those listed,use the following equation to determine the allowable capacity:P.=(T'K,)f2 <br /> vii.)1 kip=1,000 lbs <br /> viii.)Per Note 3 of ideal Group Dwg No.:278TFG dated 4/23/20,the ultimate structural capacity for the 2 7/8"TRU-FORCE Underpinning Bracket is limited to <br /> 60 kips. <br /> L120 ENGINEERING&DESIGN <br />