My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9512 HOLLY DR 2023-06-22
>
Address Records
>
HOLLY DR
>
9512
>
9512 HOLLY DR 2023-06-22
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/22/2023 11:42:29 AM
Creation date
6/22/2023 11:41:52 AM
Metadata
Fields
Template:
Address Document
Street Name
HOLLY DR
Street Number
9512
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
36
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
, <br /> • • <br /> • The house is required to have a heating system per IRC Section R303.9. The type and location of the <br /> system should be specified. If the system is new, it should be indicated as such in the drawings. Gas <br /> appliances are prohibited in the locations specified in Section G2406. <br /> Response:Exis g electric water heater is located in the room adjacent to the kitchen. <br /> P M-P <br /> • The house is required to have a water heating system per IRC Section R306.4. The type and location of <br /> the system should be specified. If the system is new, it should be indicated as such in the drawings. <br /> Seismic restraints should be provided per Section M1307.2. Gas appliances are prohibited in the <br /> ' / locations specified in Section G2406. <br /> V Response:Existing electric water heater is located in the room adjacent to the kitchen. <br /> /, • The sleeping rooms are required to be classified per IRC Section R330.3. <br /> Response:See floor plan for sleeping room classification, see resident count per room schedule as well. <br /> Structural: <br /> • The proposed project includes structural work. Structural drawing should be submitted that include <br /> framing plans, sections, details, construction schedules, fastening schedules, materials requirements, <br /> general notes, special inspection requirements, etc. The drawings should substantiate compliance with <br /> the prescriptive requirements of the IRC. See IRC Sections R106.1.1 and R301.1. <br /> Response: Existing work was done by the previous home owner. Attached plans includes pictures of the <br /> work that was performed. <br /> • The modified load paths should comply with the prescriptive limitations of the IRC. Alternatively, an <br /> engineered analysis and design may be performed per IRC Section R301.1.3; sealed and signed <br /> drawings and calculations prepared by a professional engineer licensed in the state of Washington are <br /> required per RCW 18.43.010, 18.43.020, and 18.43.070. See IRC Section R301.1. <br /> Response: Existing work was done by the previous home owner. Attached plans includes pictures of the <br /> work that was performed. <br /> • The project appears intended to include prefabricated roof trusses. See IRC Section R802.10. The <br /> following comments should be addressed: <br /> a) The design criteria for the trusses should be specified in the drawings. See Table R301.2(1) and <br /> EMC Section 16.01.010(J). <br /> • The drawings should include a note specifying the following: <br /> i) The trusses should be designed by a professional engineer licensed in the state of Washington. <br /> Response: New owner(Amos Kihara)purchased property with the remodel complete. He was not involved <br /> in any of the truss work.A visual inspection of the trusses, they are engineered trusses. <br /> ii) The truss construction drawings and calculations should bear the seal and signature of the engineer <br /> performing the design. <br /> 315 <br />
The URL can be used to link to this page
Your browser does not support the video tag.