Laserfiche WebLink
EV E R E T T December 17, 2020 <br /> WASHINGTON Rich Denny <br /> rich@inclign.com <br /> Inclign LLC <br /> Marysville,WA 98270 <br /> Owner: Maria Soriano <br /> Job Address: 1313 50th St SE <br /> Plan Check No: C2008-002 <br /> RE: Building Permit Review Letter <br /> Dear Mr. Denny, <br /> In response to the application for a building permit,the plans have been <br /> examined and you are advised that revisions may be necessary before a permit <br /> can be issued. Please review and respond to the comments below. <br /> 1. Drawings do not appear to contain architectural details such as wall,floor, <br /> and roof construction assemblies, insulation details,crawlspace details. Please <br /> provide such construction details for clarity. Please note that such details are <br /> required to demonstrate compliance with the WSEC 502.1.1.1 for the building <br /> envelope on proposed additions. IRC R106.1.1. <br /> 2. The proposed new porch and stairs appears to be missing framing and <br /> foundation details,guardrail and handrail details. IRC R106.1.1, R311.7.5, <br /> R311.7.8, R312.1. <br /> 3. On Sheet A2,the stairs from the proposed porch appears to be missing an <br /> exterior landing. Please verify and provide a landing as required. IRC R311.7.6. <br /> 4. On Sheet A2,the doors leading to the exterior appear to be missing a <br /> landing. Please verify and revise drawings as required. IRC R311.3.2. <br /> 5. On Sheet SO, a new glulam beam is proposed to replace an existing bearing <br /> wall. Please provide a size,framing details,and supporting design calculations <br /> for the beam, potential posts and verify the existing footings are adequate for <br /> PERMIT SERVICES the proposed alteration as these appear to be missing in the submittal and <br /> construction documents. Please note that this appears to constitute <br /> 9 3200 Cedar Street engineered design. Please verify that such a design is stamped and detailed by <br /> Everett,WA 98201 a licensed engineer in the state of Washington. IRC R106.1.1, R301.1.3. <br /> 0 425.257.8810 <br /> 425.257.8857 fax 6. On Sheet A2,the proposed new walls being installed in the existing garage do <br /> appear to have details provided. Please verify and revise drawings such that <br /> ::: everetteps@everettwa.gov the wall construction is meeting the minimum dwelling-garage fire separation <br /> everettwa.gov/permits requirements. IRC R302.6. <br /> Page 1 of 2 <br />