9113 9TH AVE SE 2023-06-23
>
Address Records
>
9TH AVE SE
>
9113
>
9113 9TH AVE SE 2023-06-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2023 10:02:13 AM
Creation date
6/23/2023 9:58:55 AM
Metadata
Fields
Template:
Address Document
Street Name
9TH AVE SE
Street Number
9113
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
„ . • <br /> 7. A 26 GA STRAP and other information that conform with Section M1307.2 was added on <br /> water heater. <br /> Structural <br /> 1. a. On Existing Floor Plan Sheet A6, all walls to be demolished was specified through light <br /> weight hidden lines. A legend was added below the plan, specifying the wall to be <br /> demolished and to be retained. <br /> b. The existing roof line was added on the existing floor plan. It was labeled with the type <br /> of framing used, location and span. <br /> c. A note was added on Sheet A6 &A7 requiring the contactor to verify the existing roof <br /> framing and verify that the walls proposed to be demolished are not load bearing. <br /> 2. General Fastener Schedule was provided in Sheet A3. A note specifying the used for <br /> connections of specific fastener was added on the sheet. <br /> 3. Detail 9/A5 was revised to comply with the required vertical and lateral connections per <br /> Section R507.8. <br /> 4. A sufficient embedment required by Sections R403.1.4 was provided for the deck <br /> foundation. <br /> 5. To identify the minimum required king and jacks for headers, a table showing minimum <br /> number of full-height studs at each end of headers in exterior walls was added on Sheet A5. <br /> 6. a. The anchor size specified in detail 4/A4 was revised into a minimum anchor size of 5/8 <br /> inches. <br /> b. A minimum of 3 inches anchor's embedment to existing footing was added to detail 4/A4. <br /> c. A #4 reinforcement bar embed 3 inches minimum into side stem wall and slab at 48 <br /> inches maximum on center spacing was provided to detail 4/A4. <br /> All identified issues on the initial proposal were address through this response. <br /> Sincerely, <br /> ••e) Perez <br /> Drafting Northwest/JoeydesignLLC <br /> draftingnw@gmail.com <br /> 2 I ?„. <br />
The URL can be used to link to this page
Your browser does not support the video tag.