Laserfiche WebLink
6 of 23 <br /> A PROJECT NO. SHEET NO. <br /> r- S201001-1 XR <br /> ��llP PROJECT 518 51ST ST SW, EVERETT, WA 98203 <br /> LONGITUDE SUBJECT <br /> ONE TWENTY FY 12/29/2020 <br /> ENGINEERING&DESIGN BY DATE <br /> Ideal Foundation Systems 2-7/814 Helical Pile(0.203-inch wall thickness)-Soil Capacity per ESR-3750 <br /> DIGGA 6K Drive Head Torque Correlation Factor, Kt UltimateAxial Compressive Allowable Axial Compressive <br /> Torque,T <br /> Pressure (ft*!bs) Compression Capacity, P.=1c*T Capacity, Pa=0.5*P„ <br /> (psi) (ft') (laps) (kips) <br /> 500 1,554 9 14.0 7.0 <br /> 600 1,865 9 16.8 8.4 <br /> 700 2,176 9 19.6 9.8 <br /> 800 2,486 9 22.4 11.2 <br /> 900 2,797 9 25.2 12.6 <br /> 1000 3,108 9 28.0 14.0 <br /> 1100 3,419 9 30.8 15.4 <br /> 1200 3,730 9 33.6 16.8 <br /> 1300 4,040 9 36.4 18.2 <br /> 1400 4,351 9 39.2 19.6 <br /> 1500 4,662 9 420 21.0 <br /> 1600 4,973 9 44.8 22.4 <br /> 1700 5,284 9 47.6 23.8 <br /> 1800 5,594 9 50.3 25.2 <br /> 1900 5,905 9 53.1 26.6 <br /> 2000 6,216 9 55.9 28.0 <br /> MAX 2100 6,527 9 58.7 29.4 <br /> i.)DIGGA 6K Drive Head differential pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> ii.)Per Table 5A of ESR-3750,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,300 ft*Ibs.Per Ideal <br /> Manufacturing,Inc.,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,000 ft*ibs.Final installation torque shall not <br /> exceed the lesser of these limiting values. <br /> iii.)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in the structural <br /> package,but shall not exceed the maximum allowable capacity for any part of the pile assembly. <br /> iv.)Refer to ESR-3750 and Ideal Manufacturing,Inc, documents for additional information and requirements. <br /> v.)Definitions per ESR-3750: <br /> T=Final Installation torque in ft*lbs;the last torque reading taken during pile installation,using,for example,the torque reading <br /> instruments connected to the installation equipment. <br /> Kt=Torque correlation factor per ESR-3750 <br /> P„=Ultimate axial compressive capacity(in kips)of helical pile <br /> Pa=Allowable axial compressive capacity(in kips)of helical pile <br /> vi.)For torque readings between those listed,use the following equation to determine the allowable capacity:Pa=(T"k,/2 <br /> vii.)1 kip=1,000 lbs <br /> 1 1�4 L.d FL, , y,il- !y E". <br /> L120 ENGINEERING&DESIGN <br />