My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
518 51ST ST SW 2023-06-23
>
Address Records
>
51ST ST SW
>
518
>
518 51ST ST SW 2023-06-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2023 4:12:42 PM
Creation date
6/23/2023 4:11:45 PM
Metadata
Fields
Template:
Address Document
Street Name
51ST ST SW
Street Number
518
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• 7 of 23 <br /> A PROJECT NO. SHEET NO.Irtlr.- S201001-1XR <br /> ice` <br /> ��IP <br /> PROJECT 518 51ST ST SW, EVERETT, WA 98203 <br /> LONGITUDE SUBJECT <br /> ONE TWENTY° <br /> ENGINEERING&DESIGN BY FY DATE 12/29/2020 <br /> Ideal Foundation Systems 2-7/8••0 Helical Pile(0.203-inch wall thickness)-Soil Capacity per ESR-3750 <br /> DIGGA 10K Drive Torque Correlation Factor, Kt Ultimate Axial Comp <br /> ressive Allowable Axial Compressive <br /> Head Torque,T <br /> Pressure (f[•lbs) Compression Capacity, P„=K,'T Capacity, P,=05•P„ <br /> (psi) 1ft'1 (kips) {kips) <br /> 500 1,740 9 15.7 7.8 <br /> 600 2,088 9 18.8 9.4 <br /> 700 2,436 9 21.9 11.0 <br /> 800 2,784 9 25.1 12.5 <br /> 900 3,132 9 28.2 14.1 <br /> 1000 3,480 9 31.3 15.7 <br /> 1100 3,828 9 345 17.2 <br /> 1200 4,176 9 37.6 18.8 <br /> 1300 4,524 9 40.7 20.4 <br /> 1400 4,872 9 43.8 21.9 <br /> 1500 5,220 9 47.0 23.5 <br /> 1600 5,568 9 50.1 25.1 <br /> 1700 5,916 9 53.2 26.6 <br /> 1800 6,264 9 56.4 28.2 <br /> MAX 1900 6,612 9 595 29.8 'See Note viii <br /> 2000 6,960 9 62.6 31.3 <br /> 2100 7,308 9 65.8 32.9 <br /> 2200 7,656 9 68.9 345 <br /> 2300 8,000 9 72.0 36.0 'See Note ii <br /> I.)DIGGA 10K Drive Head differentia/pressure display to torque output has been pulled from the attached conversion charts provided by DIGGA. <br /> ii.)Per Table 5A of ESR-3750,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,300 ft•Ibs. <br /> Per Ideal Manufacturing,Inc.,the maximum installation torque rating of a 2-7/8"0 helical pile(0.203-inch wall thickness)is 8,000 tt•Ibs.Final <br /> installation torque shall not exceed the lesser of these limiting values,. <br /> iii.)Piles shall reach a torque that correlates with an allowable capacity that meets or exceeds the maximum allowable load demand as listed in <br /> the structural package,but shall not exceed the maximum allowable capacity for any part of the pile assembly. <br /> iv.)Refer to ESR-3750 and heal Manufacturing,Inc. documents for additional information and requirements. <br /> v.)Definitions per ESR-3750: <br /> T=Final Installation torque in ft`lbs;the last torque reading taken during pile installation,using,for example,the torque <br /> reading instruments connected to the installation equipment. <br /> K,=Torque correlation factor per ESR-3750 <br /> P„=Ultimate axial compressive capacity(in kips)of helical pile <br /> P,=Allowable axial compressive capacity(in kips)of helical pile <br /> vi.)For torque readings between those listed,use the following equation to determine the allowable capacity:P,=(T'K,)/2 <br /> vii.)1 kip=1,000 lbs <br /> viii.)Per Note 3 of Ideal Group Dwg No.278TFG dated 4/23/20,the allowable structural capacity for the 2 7/8"TRU-FORCE Underpinning Bracket is limited to 30 kip. <br /> L120 ENGINEERING&DESIGN <br />
The URL can be used to link to this page
Your browser does not support the video tag.