My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1726 63RD ST SE 2023-06-23
>
Address Records
>
63RD ST SE
>
1726
>
1726 63RD ST SE 2023-06-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2023 4:37:34 PM
Creation date
6/23/2023 4:37:08 PM
Metadata
Fields
Template:
Address Document
Street Name
63RD ST SE
Street Number
1726
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> October 7, 2021 <br /> Rakeeb Khan, Residential Plans Examiner <br /> (425)257-7299 rkhanna everettwa.gov <br /> 3200 Cedar Street <br /> Everett, WA 98201 ate Vet <br /> RE: Owner: Randy and Lauri Hessen OCT 2 20 <br /> 2 <br /> 1 <br /> Job Address: 1726 63rd St SE Everett, WA 98203 CI T <br /> Plan Check Numb 2108-06 , First Building Review Pp OFEVERFTT <br /> Serv>c <br /> es <br /> Dear Rakeeb, <br /> Please except this letter and the attached documents in response to your review comments dated, <br /> September 10, 2021. <br /> General <br /> X. The plans are unclear on what portions of framing is being restored/rebuilt due to the fire <br /> and what is to remain. From our conversation on the phone the South portion of the home has <br /> structural damage and is being rebuilt while the framing in the North portion is to remain, but <br /> insulation and finishes are to be replaced. Drawings should be updated to clearly indicate the scope of <br /> work. Framing plans should distinguish new and existing framing. <br /> See added wall key and detailed work description on sheets Al and A2 and thru out the plan set. Plan <br /> prints have been highlighted as well for additional delineation of work. <br /> Architectural <br /> ,A'. The roof eaves project approximately 3.5 feet from the property line on the West side of the <br /> structure per the site plan. In this location, one-hour construction is required on the underside of the <br /> eaves (see alternatives and exceptions provided). In most solutions, the soffit venting will not be <br /> permitted in the eaves in these locations and the roof venting should be relocated to an approved <br /> location. Table R302.1(1) Existing over hangs per as built measurement extend a maximum of 1'-4" <br /> into setback, fire blocking shall be provided at wall/truss connection. <br /> ee Sheet A-4, Building Section A-A. <br /> ,,,i Garage separation from habitable rooms above should be updated to 5/8" Type X gypsum <br /> board. The beam revealing in the garage should be wrapped with the Type X gypsum board as well. <br /> Table R302.6 See general note floor plan note#21 sheet Al for 5/8" Type 'X' fire rated gypboard <br /> locations, details have been updated as needed. <br /> A. The insulation in the ceiling should be updated to R-49 as shown in Section 1 on Sheet S-3. <br /> Note 10 on Sheet A-1 should be updated to specify minimum R-49 ceiling insulation. See the selected <br /> energy credit option 1.3. Insulation at ceiling shall be R-49 and R-38 dense batt with advanced <br /> framing/ raftered locations per energy credit option 1.3. <br /> I The floor insulation should be updated to R-38 per the energy credits provided. Note 11 on <br /> Sheet A-1 should be updated to specify minimum R-38 floor insulation. See the selected energy credit <br /> option 1.3. Insulation notations at the floors have been updated to R-38 dense or standard batt as <br /> applicable due to existing framing dimension. <br /> I 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.