Laserfiche WebLink
• <br /> 1PFORTE" <br /> WEB JOB SUMMARY REPORT <br /> Hessen Fire Rebuild <br /> Level <br /> Member Name Results Current Solution Comments <br /> Roof: Drop Beam deck ridge Passed 1 piece(s)6 x 12 DF No.1 <br /> Roof:Drop Beam deck bearing Passed 1 piece(s)4 x 10 HF No.2 <br /> Roof:Drop Beam deck gable end Passed 1 piece(s)6 x 12 DF No.1 <br /> Wall:Header bay window Passed 1 piece(s)4 x 10 HF No.2 <br /> Roof: Drop Beam at stair Passed 1 piece(s)4 x 10 HF No.2 <br /> Roof:Flush Beam at existing Passed 1 piece(s)4 x 8 HF No.2 <br /> dormer <br /> Floor:Joist with cant Passed 1 piece(s)2 x 10 HF No.2©16"OC <br /> Floor:Drop Beam extg Passed 1 piece(s)4 x 8 HF No.1 <br /> verification <br /> Floor:Drop Beam deck beam Passed 1 piece(s)4 x 10 HF No.2 <br /> Floor:Joist deck max Passed 1 piece(s)2 x 8 HF No.2 @ 16"OC <br /> a a I s . <br /> OCT 2 2 2021 <br /> RED EO <br /> k:�-�' CITE ®F ERETT <br /> �- Permit services <br /> anti OF <br /> ForteWEB Software Operator Job Notes 8/23/2021 6:46:38 PM UTC <br /> Ruth Gonzales Fire rebuild Everett,Washington <br /> Gonzales Design Partners ForteWEB v3.2 <br /> (425)344-9942 <br /> GonzalesDesignPartners©hotmail.com Weyerhaeuser File Name: Hessen Fire Rebuild <br /> Page 1 / 11 <br />