My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1726 63RD ST SE 2023-06-23
>
Address Records
>
63RD ST SE
>
1726
>
1726 63RD ST SE 2023-06-23
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/23/2023 4:37:34 PM
Creation date
6/23/2023 4:37:08 PM
Metadata
Fields
Template:
Address Document
Street Name
63RD ST SE
Street Number
1726
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i <br /> 2018 Washington State Energy Code-Residential <br /> Prescriptive Energy Code Compliance for All Climate Zones in Washington <br /> Single Family-New&Additions(effective February 1,2021) Version 1.0 <br /> These requirements apply to all IRC building types, including detached one- and two-family <br /> dwellings and multiple single-family dwellings(townhouses). <br /> Project Information Contact Information <br /> Hessen family Fire Restoration Gonzales Design Partners 425-344-9942 <br /> 1726-63rd_Street SE, Everett Wa 98203 P.O. Box 97,Arlington WA 98223 <br /> Instructions:This single-family project will use the requirements of the Prescriptive Path below and <br /> incorporate the minimum values listed. Based on the size of the structure,the appropriate number of <br /> additional credits are checked as chosen by the permit applicant. <br /> Provide all information from the following tables as building permit drawings:Table R402.1-Insulation and <br /> Fenestration Requirements by Component,Tabl R406.2-Fuel Normalization Credits and 406.3-Energy Credits. <br /> I - <br /> Authorized Representative (, �l/ Date 08/24/2021 <br /> All Climate Zones(Table R402.1.1) <br /> I— { <br /> —. — — R-Value a U-Factor a <br /> Fenestration U-Factor b n/a 0.30 <br /> Skylight U-Factor b n/a 0.50 <br /> Glazed Fenestration SHGC b,e n/a n/a <br /> Ceiling e 49 0.026 <br /> Wood Frame Wall g•h 21 int _ 0.056 <br /> Floor 30 0.029 <br /> Below Grade Wall`•h 10/15/21 int+TB 0.042 <br /> Slab d,f R-Value&Depth 10,2 ft n/a <br /> R-values are minimums.U-factors and SHGC are maximums.When insulation is i tal r. in e.,. l a <br /> a than the label or design thickness of the insulation,the compressed R-value of th 'ni• , "' p <br /> Table A101.4 shall not be less than the R-value specified in the table. <br /> b The fenestration U-factor column excludes skylights. <br /> "10/15/21+5TB"means R-10 continuous insulation on the exterior of the wall,or 15 c ' u 2I tion o <br /> the interior of the wall,or R-21 cavity insulation plus a thermal break between the ab and the basement wale <br /> c the interior of the basement wall. "10/15/21+5TB"shall be permitted to be met a ENIFiFan <br /> the interior of the basement wall plus R-5 continuous insulation on the interior or'exteriFtreqfrtfit figilID6t1146 <br /> means R-5 thermal break between floor slab and basement wall. <br /> d R-10 continuous insulation is required under heated slab on grade floors.See Section R402.2.9.1. <br /> For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38 if the full insulation depth <br /> e extends over the top plate of the exterior wall. <br /> R-7.5 continuous insulation installed over an existing slab is deemed to be equivalent to the required perimeter <br /> f slab insulation when applied to existing slabs complying with Section R503.1.1. If foam plastic is used,it shall <br /> meet the requirements for thermal barriers protecting foam plastics. <br /> For log structures developed in compliance with Standard ICC 400,log walls shall meet the requirements for <br /> g climate zone 5 of ICC 400. <br /> Int.(intermediate framing)denotes framing and insulation as described in Section A103.2.2 including standard <br /> h framing 16 inches on center,78%of the wall cavity insulated and headers insulated with a minimum of R-10 <br /> insulation. <br /> Prescriptive Path—Single Family 2018 Washington State Energy Code-R 1 13 <br />
The URL can be used to link to this page
Your browser does not support the video tag.