Laserfiche WebLink
WSU Code Compliance Calculator,WSEC 2018 <br /> Projectlnforma8on Messages I Results*- <br /> Bikrampal Pannu Existing House Credit requirements are not met. Select energy credits from Tables 406,2 and 406.3 below -_ <br /> Review required for custom entries:-Doors-Overhead Glazing-Vertical Glazing-Flat/Vaulted Ceilings <br /> Correct errors below, <br /> Contact information <br /> 2126 124th Street SE Everett,WA <br /> Whole House Mechanical Ventilation Airflow Rate:150 CFM with Run Time Percent of 50%,Unbalanced,Not Distributed <br /> Maximum allowable total measured duct leakage:50 CFM25 <br /> •Results assume your inputs are complete and correct.Results do not constitute an approval.Analysis should be reviewed by your AFUJ. <br /> ANALYSIS SET UP <br /> What code compliance pathway are you using? Prescriptive Path Compliance with Option 1(preferred) <br /> Project Building Type? Addition <br /> Occupancy Type? R3 Single family homes and duplexes <br /> Code Version? WSEC 2018 <br /> Classification: Medium Dwelling Unit-1677.sq.ft. <br /> . <br /> Baseline Description: Code Baseline-Baseline and proposed window areas are equal. <br /> About Your Selection: Up to 15 sf exempt window and 24 sf exempt door allowable <br /> RESULTS-Comparison of Baseline and Proposed Design , <br /> Component Performance,R occupancies Baseline Proposed Design <br /> U Area UA U Area UA <br /> Doors U= 0.300 18 5.3 1.400 18 24.9 <br /> Overhead Glazing U= 0.500 8 4.0 0.500 - 8 4.0 <br /> Vertical Glazing U= 0.300. 159 47.7 0.550 159. 87.5 <br /> FlatNaulted Ceilings U= 0.027 1,677 45.3 - 0.034 1,677 57.0 <br /> Wall(above grade) U= 0.056 1,416 79.3 0.088 1,416 124.6 <br /> Floors over Crawlspace U= 0.029 1,677 48.6 0.029 1,677 48.6 <br /> Slab on Grade F= 0.540 0 0.0 0 0.0 <br /> Below Grade Wall U= 0.042 0 0.0 0 0.0 <br /> Below Grade Slab F= 0.570 0 - 0.0 - 0 0.0 <br /> Baseline UA Total Check Missing Inputs or Errors Proposed UA Total Check Missing Inputs or Errors <br /> Required Credits 6.0 Proposed Credits 0.0 from Tables 406.2 and 406.3 <br /> UA Percent Reduction <br /> UA Reduction <br /> If the Proposed UA<_the Target UA,and the Proposed Credits from Table 406 are>_those required in Section R406,then the home meets the WSEC. <br /> Table R406.2 Fuel Normalization Credits <br /> Fuel Normalization Total Credits <br /> System No. Full Description Select System Type Credits(406.2) Energy Credits(406.3) (406.2 8,406.3) <br /> NA NA 0.0 0.0 <br /> Table R406.3 Energy Credits <br /> Energy <br /> Option No. Category Select Options Credits Brief Description of Selected Options" <br /> 1 Efficient Building Envelope 0.0 <br /> 2 Air Leakage Control and Efficient Ventilation 0.0 <br /> 3 High Efficiency HVAC 0.0 <br /> 4 High Efficiency HVAC Distribution System 0.0 <br /> 5.1 Efficient Water Heating 0.0 <br /> 5.2-5.6. Efficient Water Heating 0.0. <br /> 6 Renewable Electric Energy kWh 0.0 <br /> 7 Appliance Package 0.0 <br /> Energy Credits 0.0 <br /> "Refer to WSEC 2018 Table R406.3 for complete option descriptions and requirements <br /> https://netorgft3133465-my.sharepoint.com/personal/zeroenergyhomes_becenergy_net/Documents/Documents/00A1-BEC-2021/A1-Clients_2022_BEC/Jim Hollinger/Pannau Residence/WSU Forms/Existing Heat Load <br /> Calculations_Pannu.xlsm 3/21/2022 3/21/2022 <br />