Laserfiche WebLink
WSU Code Compliance Calculator,WSEC 2018 <br /> THERMAL ENVELOPE DETAILS-Proposed Design <br /> Conditioned Floor Area of Addition,Proposed Design 1,677 sq.ft <br /> Classification Medium Dwelling Unit <br /> Notes <br /> Exterior Doors <br /> Plan Component Door Width Height <br /> ID Description Ref. U Qt. Feet tth'" Feet inch Area UA <br /> Exempt WSEC_R303.1.3(2)Default Single non-metal U-value Custom 1.40 1 3 ° 6 s 20 28.0 Refer to WSEC R402.1 <br /> WSEC_R303.1.3(2)Default Sinole non-metal U-value Custom 1.40 1 2 8 6 s 18 24.9 Refer to WSECR402A <br /> 0 0.0 <br /> 0 0.0 <br /> 0 0.0 <br /> 0 0.0 <br /> 0 0.0 <br /> 0 0.0 <br /> O 0.0 <br /> O 0.0 <br /> O 0.0 <br /> Sum of Area and UA(excluding exempt door) 18 24.9 <br /> Exterior Doors Area Weighted U 1.400 <br /> Overhead Glazing <br /> Plan Component Glazing Width Height <br /> ID Description Ref. U QL Feet '"`" Feet In' Area UA <br /> WSEC Compliant U-0.50 Custom 0.50 2 2 ° 2 ° 8.0 4 Refer to WSEC R402.1 <br /> Sum of Area and UA 8.0 4 <br /> Overhead Glazing Area Weighted U 0.500 <br /> Vertical Glazing Schedule Rows to Show 12 <br /> Plan Component Glazing Width Height <br /> ID Description Ref. U Qt. Feet I"`" Feet l'h Area UA <br /> Exempt - - - <br /> 1 WSEC_R303.1.3(1)Default double non-metal U-value Custom 0.55 2 2 ° 4 ° 16.0 8.80 Refer to WSEC R402.1 <br /> 2 WSEC_R303.1.3(1)Default double non-metal U-value Custom 0.55 1 4 ° 4 ° 16.0 8.80 Refer to WSEC R402.1 <br /> 3 WSEC_R303.1.3(1)Default double non-metal U-value Custom 0.55 2 1 ° 5 ° 10.0 5.50 Refer to WSEC R402.1 <br /> 4 WSEC_R303.1.3(1)Default double non-metal U-value Custom 0.55 1 6 ° 5 ° 30.0 16.50 Refer to WSEC R402.1 <br /> 5 WSEC_R303.1.3(1)Default double non-metal U-value Custom 0.55 1 6 ° 6 s 40,0 22.00 Refer to WSEC R402.1 <br /> 6 WSEC_R303.1.3(1)Default double non-metal U-value Custom 0.55 2 5 ° 3 6 35.0 19.25 Refer to WSEC R402.1 <br /> 7 WSECR303.1.3(1)Default double non-metal U-value Custom 0.55 1 4 ° 3 ° 12.0 6.60 Refer to WSEC R402.1 <br /> 8 - - <br /> 9 - - <br /> 10 - - <br /> 11 - - <br /> 12 - - <br /> Sum of Area and UA 159.0 87.5 <br /> Vertical Glazing Area Weighted U 0.550 C Area-weighted average <br /> Vertical Glazing and Doors Area Weighted U 0.635 <br /> FlatNaulted Ceilings <br /> Plan Component Attic <br /> ID Description Ref. U Area UA <br /> R35 blown Attic baffled Custom 0.034 1,677 57.0 Refer to WSEC R402.1 <br /> Sum of Area and UA 1,677 57.0 <br /> Walls(Above Grade) <br /> Plan Component Wall <br /> ID Description Ref. U Net Area UA <br /> R11 cavity+RO foam STD 2X4W Lap 10-5 0.088 1,416 125 <br /> -//G <br /> https://netorgft3133465-my.sharepoint.com/personal/zeroenergyhomes_becenergy_net/Documents/Documents/00A1-BEC-2021/A1-Clients_2022_BEC/Jim Hollinger/Pannau Residence/VVSU Forms/Existing Heat Load <br /> Calculations Pannu.xlsm 3/21/2022 3/21/2022 <br />