I <br /> Bikrampal Pannu <br /> Plan Check Number: B2204-008, First Building Review <br /> May 6, 2022 <br /> Structural <br /> 1. A general fastener schedule should be provided per IRC Table R602.3(1). Providing a reference <br /> to this table in the drawings does not satisfy this requirement. In addition, the make and model <br /> of proprietary hardware should be specified where used for connections, including but not <br /> limited to connections between floor and foundation elements in Detail WD on Sheet 2. See <br /> Section R106.1.1. <br /> 2. See Foundation Plan on Sheet 2. Drawings should specify the footing size and depth of the <br /> interior spread footings supporting the posts. Drawings should specify the required footing <br /> reinforcement. R403.1.3, R106.1.1 <br /> 3. See Sheet 2. Drawings should specify post sizes. R106.1.1 <br /> 4. The drawings should include a note specifying the following: <br /> a. The trusses should be designed by a professional engineer licensed in the state of <br /> Washington. <br /> b. The truss construction drawings and calculations should bear the seal and signature of <br /> the engineer performing the design. <br /> c. The truss design should be reviewed for conformance with the approved construction <br /> drawings and the referenced building codes and approved for construction by the <br /> designer-of-record for the approved drawings, prior to fabrication and erection. <br /> This review has been performed for general compliance with the building codes as adopted and <br /> amended by the state of Washington and the city of Everett. Corrections and comments made <br /> during the review process do not relieve the project from compliance with code and permit <br /> requirements. The designers-of-record are responsible for a complete design in accordance with <br /> the laws of the state of Washington. <br /> If you have any questions or require additional clarification, please contact us. <br /> Respectfully, <br /> Rakeeb Khan <br /> Residential Plans Examiner <br /> (425)257-7299 <br /> rkhan@everettwa.gov <br /> S:\RKha n\2022\B2204-008_R1.docx <br /> 0 3200 Cedar Street © 425.257.8810 O everetteps@everettwa.gov <br /> Everett,WA 98201 425.257.8857 fax everettwa.gov/permits <br /> Z 3 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.