MIMIMUM HANGER SIZES FOR RECTANGULAR DUCT <br />MAXIMUM <br />OF <br />PAIR@10'SPACING <br />PAIR@8'SPACING <br />PAIR@TSPACING <br />PAIR@4'SPACING <br />HALF DUCT <br />PERIMETER <br />STRAP <br />WIREIROD <br />STRAP <br />WIRE/ROD <br />STRAP <br />WIRE/ROD <br />STRAP <br />WIRE/ROD <br />P/2=30" <br />1"x22 GA <br />10 GA <br />I"x22 GA <br />IO GA <br />1"x 22 GA <br />12 GA <br />1"x22 GA <br />12 GA <br />P/2-72" <br />1"x IS GA <br />3/8" <br />1"x20GA <br />1/4" <br />1"x22 GA <br />1/4" <br />1"z22 GA <br />1/4" <br />P/2=96" <br />1"x16 GA <br />3/8" <br />1"x 18 GA <br />3/8" <br />1"x 20 GA <br />3/8" <br />1"x20GA <br />3/8" <br />P/2=120" <br />1.5"x 16 GA <br />1/2" <br />1"x 16 GA <br />3/9. <br />1"x 18 GA <br />3/8" <br />1"x18GA <br />3/9' <br />P/2=168" <br />1.5"x16 GA <br />1/2" <br />1.5"x16GA <br />1/2" <br />1"xI6GA <br />3/8" <br />1"xI6GA <br />3/8" <br />P/2=192" <br />NOT GIVEN <br />1/2" <br />1.5"x16GA <br />1/2" <br />1"xI6GA <br />3/8" <br />1"x16 GA <br />3/8" <br />P/2> 192" <br />SPECIALANALYSIS REQUIRED <br />WHEN STRAPSARE LAP JOINED <br />USE THESE MINIMUM <br />SINGLE HANGER MAXIMUM <br />ALLOWABLE <br />LOAD IN LBS. <br />FASTENERS <br />STRAP <br />WIRE OF ROD(DIA.) <br />1"x 22 GA <br />260 <br />0.116" <br />80 <br />1- A20,22 GA- TWO #10 OR ONE 1/4" BOLT <br />1"x 16 GA -TWO I/4"DIA. <br />1"x 20 GA <br />320 <br />0.135" <br />120 <br />1.5"x 16 GA -TWO 3/8"DIA. <br />1"x 18 GA <br />420 <br />0.162" <br />160 <br />1" x 16 GA <br />70 <br />1/4" <br />270 <br />PLACE FASTEN ERS I N SERI ES, NOT SI DE BY SIDE. <br />1.5"x22 GA <br />110 <br />3/8" <br />680 <br />1/2" <br />1250 <br />5/8" <br />20DO <br />3/4" <br />3000 <br />MIMIMUM HANGER SIZES FOR ROUND DUCT <br />DIAMETER <br />MAXIMUM <br />SPACING <br />WIRE <br />DIAMETER <br />ROD <br />DIAMETER <br />STRAP SIZE <br />10"or LESS <br />12' <br />1@12 GA <br />1/4" <br />1"x22 GA <br />III, TO 18" <br />12' <br />2@12 GA <br />OR <br />1@8GA <br />1/4" <br />1"x22 GA <br />19"TO 24" <br />12' <br />2@TOGA <br />1/4" <br />1"x22 GA <br />25"TO 36" <br />12' <br />2@8GA <br />3/8" <br />1"x20 GA <br />37" TO 50" <br />12' <br />n/a <br />2 @ 3/8" <br />1" x 20 GA <br />51" TO 60" <br />12' <br />n/a <br />2 @ 3/8" <br />2 @ 1" x 18 GA <br />61"TO 84" <br />12' <br />n/a <br />2@3/8" <br />2@1"x16 GA <br />C403.10.1 Duct and plenum insulation and sealing. 2018 WASHN3 011 STATEBHt3t' COOS <br />C4D3.10.1.1 Ducts conveying outdoor air. Ducts, shafts and plenums conveying outdoor air from the <br />exterior of the building to the mechanical system shall meet all air leakage and building envelope insulation <br />requirements of Section C402, plus building envelope vapor control requirements from the International <br />Building Code, extending continuously from the building exterior to an automatic shutoff damper or heating <br />or cooling equipment. For the purposes of building envelope insulation requirements, duct surfaces shall be <br />insulated with the minimum insulation values in Table C403.10.1.1. Duct surfaces included as pan of the <br />building envelope shall not be used in the calculation of maximum glazing area as described in Section <br />C402.4.1. <br />Exceptions: <br />i. Outdoor air duds serving individual supply air units with less than 2,800 cfm of total supply air <br />capacity, provided these are insulated to the minimum insulation values in Table C403.10.1.1. <br />2. Unheated equipment rooms with combustion air louvers, provided they are isolated from <br />conditioned space at sides, top and bottom of the room with R-11 nominal insulation. <br />TABLE C403.10.1.1 <br />OUTDOOR AIR DUCTWORK INSULATION <br />Minimum <br />Duet <br />Duct Location and <br />Climate <br />Airflow <br />Installed <br />Duct <br />Notes <br />system <br />Use <br />Zone <br />Insulation <br />R-value <br />Inside conditioned <br />See Section C403.10.1.1 <br />Outdoor Mr <br />space and upstream of <br />4C and <br />a 2800 CFM <br />R-16 <br />for additional <br />automatic shutoff <br />5B <br />requirements <br />damper <br />Inside conditioned <br />space and downstream <br />Outdoor Air <br />of automatic shutoff <br />4C <br />z 2800 CFM <br />R-8 <br />damper to HVAC unit or <br />room <br />Inside conditioned <br />space and downstream <br />Outdoor Air <br />of automatic shutoff <br />5B <br />a 2800 CFM <br />R-12 <br />damper to HVAC unit or <br />mom <br />Inside conditioned <br />4C and <br />See Exception 1 to <br />Outdoor Air <br />space <br />5B <br />`2800 CFM <br />R-7 <br />Section C403.10.1.1 for <br />additional details <br />a. Insulation R-values, measured in h-t2.9FA3tu, are for the insulation as installed and do not include film <br />resistance. The required minimum thicknesses do not consider water vapor transmission and possible <br />surface condensation. Insulation resistance measured on a horizontal plane in accordance with ASTM C518 <br />at a mean temperature of 75'F at the installed thickness. <br />b. See International Mechanical Code Sections 603.12 and 604 for further details on dud insulation <br />requirements. <br />C403.10.1.2 Other supply and return duds. All other supply and return air ducts and plenums shall be <br />insulated with a minimum of R-6 insulation where located in unconditioned spaces, and where located <br />outside the building with a minimum of R-8 insulation in Climate Zone 4 and R-12 insulation in Climate Zone <br />5. Where located within a building envelope assembly, the dud or plenum shall be separated from the <br />building exterior or unconditioned or exempt spaces by minimum insulation value as required for exterior <br />walls by Section C402.1.3. <br />Exceptions: <br />1. Where located within equipment. <br />2. Supply and return ductwork located in unconditioned spaces where the design temperature <br />difference between the interior and exterior of the duct or plenum does not exceed 15°F (8°C) and <br />insulated in accordance with Table C403.10.1.2. <br />Where located within conditioned space, supply ducts which convey supply air at temperatures less than <br />559F or greater than 105OF shall be insulated with a minimum insulation R-value in accordance with Table <br />C403.10.1.2. <br />Exception: Ductwork exposed to view within a zone that serves that zone is not required to be insulated. <br />Where located within conditioned space, return or exhaust air ducts that convey return or exhaust air <br />downstream of an energy recovery media shall be insulated with a minimum R-value in accordance with <br />Table C403.10.1.2. <br />All ducts, air handlers, and filter boxes shall be sealed. Joints and seams shall comply with Section 603.9 <br />of the International Mechanical Code. <br />TABLE C403,10.1.2 <br />SUPPLY, RETURN, EXHAUST, and RELIEF AIR DUCTWORK INSULATION <br />Minimum <br />Climate <br />Installed <br />Duct system <br />Duct LOtdllOn and Use <br />Zone <br />Ducl <br />Insulation <br />Notes <br />R-value <br />Supply Air or Return <br />Outside the building (outdoors and <br />4C <br />R-8 <br />See Section C403.10.1.2 for <br />AU <br />exposed to weatherp <br />details <br />Supply Air or Return <br />Outside the building (outdoors and <br />58 <br />R-12 <br />See Section C403.10.1.2 for <br />Air <br />exposed to weather)° <br />details <br />Supply Air or Return <br />Unconditioned space (enclosed but <br />4C and <br />See Section C403.10.1.2 for <br />Air <br />not in the building conditioned <br />5B <br />R-6 <br />details <br />envelope) <br />Unwndltioned space where the dud <br />See IMC Section 603.12 for <br />Supply Air or Return <br />Air <br />conveys air that is within ISOF of the <br />air temperature of the surrounding <br />40 and <br />58 <br />R-3.3 <br />additional requirements for <br />condensation control at <br />unconditioned space <br />ductwork <br />Where located In a building envelope <br />Duct or plenum is separated <br />Supply Air or Return <br />assembly <br />4C and <br />R16 <br />from building envelope <br />Air <br />513 <br />embly with the minimum <br />insulation value <br />Within conditioned space where the <br />qC and <br />See Section C403.10.1.2 for <br />Supply Air <br />supply duct conveys air that is less <br />5B <br />R-3.3 <br />details <br />than 55'F or greater than 105'F <br />Within conditioned space that the dud <br />See Section C403.10.1.2 for <br />Supply Air <br />directly serves where the supply duct <br />4C and <br />None <br />details <br />conveys air that is less than 559E or <br />5B <br />greater than 105°F <br />Within conditioned space where the <br />4C and <br />Supply Air <br />supply duct conveys air that is 55'F <br />SB <br />None <br />or greater and 106 9F or less <br />Within conditioned space. <br />Return or Exhaust <br />downstream of an energy recovery <br />4C <br />R-8 <br />Air <br />media, upstream of an automatic <br />shumff damper <br />Within conditioned space, <br />Return or Exhaust <br />Air <br />downstream of an energy recovery <br />media, upstream of an automatic <br />5B <br />R-12 <br />shutoff damper <br />Relief or Exhaust Air <br />Conditioned space and downstream <br />4C and <br />R-16 <br />of an automatic shutoff damper <br />513 <br />a. Insulation R-values, measured in R8' °F/Btu, are for the insulation as installed and do not include film <br />resistance. The required minimum thicknesses do not consider water vapor transmission and possible <br />surface condensation. Insulation resistance measured on a horizontal plane in amordance with ASTM CS18 <br />at a mean temperature of 75°F at the installed thickness. <br />b. See International Mechanical Code Sections 603.12 and 604 for further details on duct insulation <br />requirements. <br />c. Includes aides above insulated ceilings, parking garages and crawl spaces. <br />UNITEDLiji <br />SYSTEMS <br />MECHAN I CAL LL_C <br />A FULL SERVICE COMMERCIAL <br />HVAC CONTRACTOR <br />1400 AIRPORT WAY SOUTH <br />SUITE 202 <br />SEATTLE, WASHINGTON 98134 <br />(206)933-6036/FAX 937-3084 <br />lE E. Sq� <br />O 4' <br />�sSIONAL ENV <br />EXPIRES 05-09-2023 <br />10-25-22 <br />REVISIONS <br />DATE DISCRIPTION <br />F- <br />w <br />W <br />J <br />_D <br />O <br />a <br />O <br />W <br />Q <br />J <br />L.J <br />Z � <br />Z <br />j O <br />W <br />NQ0 <br />U <br />W <br />� r z <br />a <br />Z <br />Of <br />` <br />L, O <br />w Of <br />ci� m <br />r7 <br />I� <br />DJ <br />�N <br />/ <br />N W <br />Do <br />W <br />U) <br />(D M <br />FILE NAME : SVDP—M <br />PROJECT ENGINEER :,JGL <br />DATE REVISED :3-10-2023 <br />JOB NUMBER :9825 <br />SHEET NUMBER <br />M®1 <br />THESE DRAWINGS ARE THE PROPERTY OF UNITED SYSTEMS MECHANICAL LLC AND MUST NOT BE REPRODUCED, ALTERED OR USED WITHOUT THE PRIOR WRITTEN AUTHORITY OF UNITED SYSTEMS LLC. THESE DRAWINGS ARE TO BE USED ONLY AS SUPPLEMENTARY TO THE ARCHITECT'S DRAWINGS AND SPECIFICATIONS. ANY PROPOSED VARIATIONS OR DEPARTURES FROM THESE DRAWINGS MUST BE APPROVED BY UNITED SYSTEMS MECHANICAL LLC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.