Laserfiche WebLink
N <br />N <br />4 <br />cli <br />m <br />C <br />l6 <br />'DO <br />O <br />2 <br />LIGHTING NOTES <br />Provide new lighting in Unit 1313 and 1315 only. Lighting and <br />controls in existing restrooms, janitor and storage closet to <br />remain. <br />Provide daylight controls lights within Primary or Secondary <br />Lighting areas per plan. <br />WATTAGE CALCULATION <br />Retail Power Allowance per W EC TABLE C405.4.2(l): 0.84w/sf <br />Square Footage of Retail Area with New Lighting: 3573sf <br />Allowable Wattage (3573-0.84): 3,001 W <br />Provided Wattage: (per schedule): 455w <br />Lighting Schedule Units 1313-1315 <br />ID 2D Plan Preview Qty Mounting Lamp Manufacturer Product Line / ID Wattage Model <br />L1 EEEHI 13 Pendant (Aircraft Cables) LED Lithonia Lighting M 35 M L48 SOOOLM SEF FDL Mi GZ10 35K 90CRI <br />455 <br />I <br />---------------- <br />o- - - <br />Stairs To Apts. t No Change to <br />'No Work This Area tTLLN <br />Restroom Lighting <br />® ®®®®®®®®®®® or Ceilings <br />1 <br />1 No Change a Restroom V Restrooms <br />L Lighting or Ceilings L1 ,�_,.,__�� <br />1 <br />�L1 �L1 �L1 <br />L <br />1 <br />Demolish Existing Ceiling and Remove Mechanical System <br />1 <br />(New Mechanical System under Separate Permit) <br />1 <br />' <br />1 <br />1 <br />' <br />1 <br />1 <br />' <br />o- <br />---- - <br />-- <br />�L1 L1 <br />1 <br />i <br />L <br />1 <br />Unit 1313 <br />3012 sf <br />1 <br />1 <br />' <br />1 <br />L <br />F <br />No Change to Restroom, Janitor or <br />®i <br />®®®®®®®®® <br />Storage Closet Lighting or Ceilings <br />_________ <br />-__ <br />1 <br />Secondary L1 <br />� <br />L1 L <br />1 <br />Daylighting <br />6) <br />1 <br />F <br />Zone <br />_ -®®_ <br />_—®��®®® <br />®ICJ <br />-L— <br />- <br />]snit r <br />F <br />1 <br />Y-o" <br />t <br />No W rk <br />1 <br />Primary <br />1 <br />Daylighting <br />1 <br />Zone <br />Restroom <br />Star <br />Restroom <br />Extt <br />No Work <br />Work <br />No Work <br />Fr <br />Planter <br />Demolish Existing Ceiling and <br />Remove Mechanical System <br />(New Mechanical System <br />under Separate Permit) <br />Secondary <br />Daylighting <br />Zone <br />L1 .ii® _ — <br />Primary %— <br />Daylighting <br />Zone <br />Area Of Work Existing ®®® �® Existing 7 <br />Provide Daylight Responsive <br />Window Heads Window Heads <br />WSEC C405.2.4.1 Contral this Circuit per <br />at 9'-0" at 9'-0" <br />Main Floor (Partial) -Ceiling Plan <br />- <br />o- -+- <br />Vj <br />1 <br />1 <br />1 <br />1 <br />QA B Plumbing Fixtures C Plumbing Fixtures <br />Q Existing To Remain, TBD. Q Existing To Remain, TBD. <br />--- T-r <br />Stairs To Aots. <br />)Work This Areal I <br />l L ^I <br />Re lroo <br />II <br />m®�®®®® <br />w < <br />II <br />H <br />N <br />II <br />III II <br />III II <br />H <br />IL <br />p <br />�II II <br />Ir — — <br />---_— <br />JI hL <br />II �— <br />II <br />Ir—===—it----- <br />N II <br />I <br />I <br />II <br />u <br />I I <br />n <br />I I <br />II <br />Ill Unit1313 <br />II <br />IIj3012Sf <br />--=1 <br />II <br />III <br />jLll <br />�' <br />II <br />II <br />II <br />I <br />Extg. lolumn <br />II <br />Tohemain <br />II <br />■— _ — _ <br />— _ — _ — _ - _ — — <br />- <br />U I <br />Unit 1315 <br />1561 sf <br />UE) <br />- Restroomu No Restroom <br />NoWork W rok11— No Work <br />m®,®®®®®®®®®®®®®®®® ®®®®®®9®®®®®®®®®®® ®®®®®®®®®®®®®®®®®® <br />Area Of Worl< <br />Plumbing Fixtures <br />Existing To Remain, TBD. <br />Main Floor <br />= <br />0 <br />GENERAL NOTES <br />Coordinate any required service interruptions with building staff. <br />In open retail areas only: remove existing ceiling grid/ceiling, <br />demo any minor soffits. <br />Protect fire sprinkler and alarm systems in place (if any present). <br />Remove all flooring and prepare slab for new finishes, by others. <br />FLOOR PLAN LEGEND <br />Existing Wall to Remain <br />New Wall <br />Demolish Wall <br />1000 <br />Point Source Fan. Min. CFM req'd indicated. <br />CFM <br />@ <br />Combined Smoke/Carbon Monoxide Alarm. <br />Ceiling mount and hardwire. <br />oSDICO <br />I <br />O <br />I <br />Stairs <br />To Aots. <br />Unit 2826 <br />No Work This Area <br />T—F <br />h t�l <br />Unit 2828 <br />� <br />No Work This Area <br />Unit 2830 <br />No Work This Area <br />r <br />Unit 1317 <br />No Work This Area <br />Unit 1317 <br />No Wml<This Area <br />— _ — _ — _ — _ — — _ — __ — _ — _ — _ <br />Unit 1319 <br />No Work This Area <br />ADAMS <br />ARCHITECTURE <br />4530 Union Bay PI. NE <br />Seattle, WA 98105 <br />206-669-4852 <br />info@adamsarchitecture.net <br />© 2022 Adams Architecture PS <br />All Rights Reserved. <br />10119 <br />7REGISTERED <br />JOHN H. ADAMS <br />STATE OF WASHINGTON <br />Project. <br />The Hart Building <br />Tenant <br />Improvement <br />Location'. <br />1313 Hewitt Ave <br />Everett WA 98201 <br />1 <br />Issuance: <br />1/24/22 <br />Permit Set Tl <br />ID <br />Date <br />Description <br />Changes <br />Sheet: <br />Main Floor Plan <br />A1.1 <br />