Cooling' (Non -Ducted // Mix // Ducted) <br />Maximum Capacity <br />BTU/H <br />48,000 H 48,000 H 48,000 <br />Rated Capacity <br />BTU/H <br />48,000 H 48,000 H 48,000 <br />Minimum Capacity <br />BTU/H <br />W <br />16,000 H 16,000 H 16,000 <br />3,665 // 3,930 H 4,245 <br />Maximum Power Input <br />Rated Power Input <br />W <br />% <br />3,665 // 3,930 H 4,245 <br />98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 <br />Power Factor (208V, 230V) <br />Heating at 47°F2 (Non -Ducted H Mix // <br />Ducted) <br />Maximum Capacity <br />BTU/H <br />BTU/H <br />BTU/H <br />54,000 H 54,000 H 54,000 <br />54,000 H 54,000 // 54,000 <br />27,000 H 27,000 H 27,000 <br />Rated Capacity <br />Minimum Capacity <br />Maximum Power Input <br />W <br />3,955 // 4,335 H 4,795 <br />Rated Power Input <br />W <br />3,955 // 4,335 H 4,795 <br />Power Factor (208V, 230V) <br />% <br />98.5, 98.5 // 98.5, 98.5 // 98.5, 98.5 <br />Heating at 17°F3 (Non -Ducted // Mix // <br />Ducted) <br />Maximum Capacity <br />BTU/H <br />43,000 // 43,000 H 43,000 <br />Rated Capacity <br />BTU/H <br />31,400 // 31,400 H 31,400 <br />Maximum Power Input <br />W <br />5,200 H 5,650 H 6,350 <br />Rated Power Input <br />W <br />3,410 // 3,840 H 4,270 <br />Heating at 5°F4 (Non -Ducted // Mix // <br />Ducted) <br />Maximum Capacity <br />BTU/H <br />32,400 // 32,400 H 32,400 <br />Maximum Power Input <br />W <br />4,530 H 4,650 H 4,770 <br />Efficiency (Non -Ducted // Mix // Ducted) <br />SEER <br />23.0 H 19.75 H 16.5 <br />EER' <br />13.1 //12.2 //11.3 <br />HSPF (IV) <br />12.0 H 11.5 // 11.0 <br />COP at 47°F2 <br />4.0 // 3.65 // 3.3 <br />COP at 17°F at Maximum Capacity3 <br />2.1 // 1.96 // 1.7 <br />COP at 5°F at Maximum Capacity' <br />2.1 // 2.05 // 2.0 <br />ENERGY STAR® Certified <br />Yes // No // No <br />Electrical <br />Electrical Power Requirements <br />Voltage, Phase, <br />Frequency <br />208/230, 1, 60 <br />Guaranteed Voltage Range <br />VAC <br />187-253 <br />Voltage: Indoor - Outdoor, S1-S2 <br />VAC <br />208/230 <br />Voltage: Indoor - Outdoor, S2-S3 <br />V DC <br />24 <br />Short-circuit Current Rating (SCCR) <br />kA <br />5 <br />Recommended Fuse/Breaker Size if Branch Box Powered by <br />Outdoor Unit <br />A <br />30 (40) <br />Recommended Fuse/Breaker Size without Branch Box or <br />Branch Box Powered Separate <br />A <br />30 <br />Recommended Wire Size <br />AWG <br />8 <br />MCA if Branch Box Powered by Outdoor Unit <br />A <br />35.0 <br />MOCP if Branch Box Powered by Outdoor Unit <br />A <br />50 <br />MCA without Branch Box or Branch Box Powered Separate <br />A <br />29 <br />MOCP without Branch Box or Branch Box Powered Separate <br />A <br />40 <br />Fan Motor Full Load Amperage <br />A <br />0.6+0.6 <br />Outdoor unit <br />Airflow Rate (Cooling / Heating) <br />CFM <br />3,885 / 3,885 <br />Refrigerant Control <br />LEV <br />Defrost Method <br />Reverse Cycle <br />Heat Exchanger Type <br />Plate fin coil <br />Heat Exchanger Coating <br />Blue Fin Coating <br />Sound Pressure Level, Cooling' <br />dB(A) <br />51 <br />Sound Pressure Level, Heating2 <br />dB(A) <br />54 <br />Compressor Type <br />Hermetic <br />Compressor Model <br />ANB33FNHMT <br />Compressor Motor Output <br />kW <br />3.4 <br />Compressor Rated Load Amps <br />A <br />19 <br />Compressor Locked Rotor Amps <br />A <br />22.0 <br />Compressor Oil Type // Charge <br />oz. <br />FV50S // 78 <br />Base Pan Heater <br />Optional (PAC-SJ20BH-E) <br />Unit Dimensions <br />W: In. [mm] <br />41-11/32 [1,050] <br />D: In. [mm] <br />13 [330] <br />H: In. [mm] <br />52-11/16 [1,338] <br />Package Dimensions <br />W: In. [mm] <br />43 [1,090] <br />D: In. [mm] <br />18 [450] <br />H: In. [mm] <br />57 [1,430] <br />Unit Weight <br />Lbs.[kg] <br />271 [123] <br />Package Weight <br />Lbs.[kg] <br />295 [134] <br />NOTES: <br />AHRI Rated Conditions 'Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB <br />(Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB <br />31-leating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB <br />Conditions 41-leating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB <br />'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. <br />when 1 or more PIA-A-EA7 connected <br />'a Branch box should be placed within the level between the outdoor unit and indoor units <br />5°F DB - 115°F DB when optional wind baffles are installed <br />For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. <br />Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications <br />where it is known that all connected units will NOT be operating at the same time. <br />Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. <br />