My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1313 HEWITT AVE 2023-11-01
>
Address Records
>
HEWITT AVE
>
1313
>
1313 HEWITT AVE 2023-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 9:20:13 AM
Creation date
7/25/2023 6:27:58 AM
Metadata
Fields
Template:
Address Document
Street Name
HEWITT AVE
Street Number
1313
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
30
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SPECIFICATIONS: MXZ-SM48NAM <br />Outdoor unit operating temperature <br />range <br />Cooling Intake Air Temp (Maximum / Minimum') FDB <br />Cooling Thermal Lock -out / Re -start Temperatures °FDB <br />115 / 23'c <br />N/A/ N/A <br />Heating Intake Air Temp (Maximum / Minimum) <br />°FDB <br />59 / -13 <br />Heating Thermal Lock -out / Re -start Temperatures <br />°FDB <br />-24 / -14 <br />Refrigerant <br />Maximum Charge Quantity <br />Lbs, oz <br />10.0, 9.0 <br />Indoor unit connection <br />Maximum Number of Connected IDU with Branch Box <br />8(6)- <br />Maximum Number of Connected IDU without Branch Box <br />12 <br />Minimum Number of Connected IDU with Branch Box <br />12,000 <br />Minimum Number of Connected IDU without Branch Box <br />24,000 <br />Maximum connected capacity <br />62,000 <br />Piping <br />Liquid Pipe Size O.D. (Flared) <br />In.[mm] <br />3/8 [9.52] <br />Gas Pipe Size O.D. (Flared) <br />In.[mm] <br />5/8 [15.881 <br />Total Piping Length when using Branch Box <br />Ft. [m] <br />492 [150] <br />Total Piping Length without Branch Box <br />Ft. [m] <br />984 [300] <br />Maximum Height Difference's, ODU above IDU <br />Ft. [m] <br />164 [50] <br />Maximum Height Difference's, ODU below IDU <br />Ft. [m] <br />131 [40] <br />Maximum Height Difference's, between branch boxes <br />Ft. [m] <br />49 [15] <br />Maximum Height Difference between IDU and IDU without <br />branch box <br />Ft. [m] <br />49 [15] <br />Ft. [m] <br />49 [15] <br />Maximum Piping Length between ODU and Branch Box <br />Ft. [m] <br />180 [55] <br />Farthest Piping Length from ODU to IDU with Branch Box <br />Ft. [m] <br />262 [80] <br />Farthest Piping Length from ODU to IDU without Branch Box <br />Ft. [m] <br />492 [150] <br />Farthest Piping Length after Branch Box <br />Ft. [m] <br />82 [25] <br />Total Piping Length between Branch Boxes and IDU <br />Ft. [m] <br />311 [95] <br />Maximum Number of Bends for IDU <br />15 <br />NOTES: <br />AHRI Rated Conditions 'Cooling (Indoor H Outdoor) °F 80 DB, 67 WB H 95 DB, 75 WB <br />(Rated data is determined at a fixed compressor speed) 21-leating at 47°F (Indoor H Outdoor) °F 70 DB, 60 WB H 47 DB, 43 WB <br />31-leating at 17°F (Indoor H Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB <br />Conditions 41-leating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // 5 DB, 4 WB <br />'Applications should be restricted to comfort cooling only; equipment cooling applications are not recommended for low ambient temperature conditions. <br />when 1 or more PLA-A•EA7 connected <br />s Branch box should be placed within the level between the outdoor unit and indoor units <br />° 5°F DB - 115°F DB when optional wind baffles are installed <br />For actual capacity performance based on indoor unit type and number of indoor units connected, please refer to MXZ Operational Performance. <br />Although the maximum connectable capacity is 130 % , the outdoor unit cannot provide more than 100 % of the rated capacity. Please utilize this over capacity capability for load shedding or applications <br />where it is known that all connected units will NOT be operating at the same time. <br />Specifications are subject to change without notice. © 2022 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. <br />
The URL can be used to link to this page
Your browser does not support the video tag.