My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9610 19TH AVE SE DISH WIRELESS 2023-11-01
>
Address Records
>
19TH AVE SE
>
9610
>
DISH WIRELESS
>
9610 19TH AVE SE DISH WIRELESS 2023-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 8:12:09 AM
Creation date
7/27/2023 7:49:57 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9610
Tenant Name
DISH WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED 2" UNDERGROUND FIBER <br />CONDUIT (LENGTH: 75'-0"t) WITH <br />400—lb MULE TAPE TO BE INSTALLED <br />BY DISH WIRELESS, L.L.C. CONTRACTOR <br />TO COORDINATE ROUTING WITH UTILITY <br />COMPANY. SEE NOTE 3. VERIFY <br />AGAINST FINAL APPROVED TELCO <br />DESIGN PRIOR TO CONSTRUCTION. <br />DISH WIRELESS, L.L.C. CONTRACTOR TO <br />STUB UP 2" CONDUIT FOR FIBER 5 FT <br />ABOVE GRADE NEAR EXISTING FIBER <br />HAND HOLE. VERIFY AGAINST FINAL <br />APPROVED TELCO DESIGN PRIOR TO <br />CONSTRUCTION. <br />APPROXIMATE LOCATION OF <br />EXISTING FIBER HAND HOLE <br />VERIFY <br />NOTES <br />1. CONTRACTOR SHALL FIELD VERIFY ALL PROPOSED UNDERGROUND UTILITY CONDUIT ROUTE. <br />2. ANTENNAS AND MOUNTS OMITTED FOR CLARITY. <br />3. THE GROUND LEASE PROVIDES BROAD/BLANKET UTILITY RIGHTS. "PWR" AND "FBR" PATH DEPICTED ON A-1 AND E-1 ARE BASED ON BEST AVAILABLE INFORMATION INCLUDIKLd <br />BUT NOT LIMITED TO FIELD VERIFICATION, PRIOR PROJECT DOCUMENTATION AND OTHER REAL PROPERTY RIGHTS DOCUMENTS. WHEN INSTALLING THE UTILITIES PLEASE LOCATE <br />AND FOLLOW EXISTING PATH. IF EXISTING PATH IS NOT AN OPTION, PLEASE NOTIFY TOWER OWNER AS FURTHER COORDINATION MAY BE NEEDED. <br />FBR FBR - <br />m <br />A <br />m <br />FBR FBR�I PER PER <br />1 FU <br />DD <br />XI IX <br />k <br />X X <br />UTILITY ROUTE PLAN <br />APPROXIMATE LOCATION OF <br />EXISTING GROUND —MOUNTED <br />TRANSFORMER <br />FOR CONDUITS TRAVELING ACROSS <br />VEHICLE ZONES TO AVOID DAMAGE <br />PROPOSED 3" UNDERGROUND POWER <br />CONDUIT (LENGTH: 10'-0"f) FROM <br />PROPOSED 200A METER TO EXISTING <br />GROUND —MOUNTED TRANSFORMER TO BE <br />INSTALLED BY DISH WIRELESS, L.L.C. <br />CONTRACTOR TO COORDINATE ROUTING WITH <br />V UTILITY COMPANY. <br />BR X X <br />PWR <br />X <br />X <br />x <br />X X X Xu <br />DC POWER WIRING SHALL BE COLOR CODED AT EACH END FOR IDENTIFYING +24V AND —48V CONDUCTORS. <br />RED MARKINGS SHALL IDENTIFY +24V AND BLUE MARKINGS SHALL IDENTIFY —48V. <br />1. CONTRACTOR SHALL INSPECT THE EXISTING CONDITIONS PRIOR TO SUBMITTING A BID. ANY QUESTIONS ARISING <br />DURING THE BID PERIOD IN REGARDS TO THE CONTRACTOR'S FUNCTIONS, THE SCOPE OF WORK, OR ANY <br />OTHER ISSUE RELATED TO THIS PROJECT SHALL BE BROUGHT UP DURING THE BID PERIOD WITH THE PROJECT <br />MANAGER FOR CLARIFICATION, NOT AFTER THE CONTRACT HAS BEEN AWARDED. <br />2. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH CURRENT NATIONAL ELECTRICAL CODES AND ALL <br />STATE AND LOCAL CODES, LAWS, AND ORDINANCES. PROVIDE ALL COMPONENTS AND WIRING SIZES AS <br />REQUIRED TO MEET NEC STANDARDS. <br />3. LOCATION OF EQUIPMENT, CONDUIT AND DEVICES SHOWN ON THE DRAWINGS ARE APPROXIMATE AND SHALL BE <br />COORDINATED WITH FIELD CONDITIONS PRIOR TO CONSTRUCTION. <br />4. CONDUIT ROUGH —IN SHALL BE COORDINATED WITH THE MECHANICAL EQUIPMENT TO AVOID LOCATION CONFLICTS. <br />VERIFY WITH THE MECHANICAL EQUIPMENT CONTRACTOR AND COMPLY AS REQUIRED. <br />5. CONTRACTOR SHALL PROVIDE ALL BREAKERS, CONDUITS AND CIRCUITS AS REQUIRED FOR A COMPLETE SYSTEM. <br />6. CONTRACTOR SHALL PROVIDE PULL BOXES AND JUNCTION BOXES AS REQUIRED BY THE NEC ARTICLE 314. <br />7. CONTRACTOR SHALL PROVIDE ALL STRAIN RELIEF AND CABLE SUPPORTS FOR ALL CABLE ASSEMBLIES. <br />INSTALLATION SHALL BE IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. <br />8. ALL DISCONNECTS AND CONTROLLING DEVICES SHALL BE PROVIDED WITH ENGRAVED PHENOLIC NAMEPLATES <br />INDICATING EQUIPMENT CONTROLLED, BRANCH CIRCUITS INSTALLED ON, AND PANEL FIELD LOCATIONS FED FROM. <br />9. INSTALL AN EQUIPMENT GROUNDING CONDUCTOR IN ALL CONDUITS PER THE SPECIFICATIONS AND NEC 250. <br />THE EQUIPMENT GROUNDING CONDUCTORS SHALL BE BONDED AT ALL JUNCTION BOXES, PULL BOXES, AND ALL <br />DISCONNECT SWITCHES, AND EQUIPMENT CABINETS. <br />10. ALL NEW MATERIAL SHALL HAVE A U.L. LABEL. <br />11. PANEL SCHEDULE LOADING AND CIRCUIT ARRANGEMENTS REFLECT POST —CONSTRUCTION EQUIPMENT. <br />12. CONTRACTOR SHALL BE RESPONSIBLE FOR AS —BUILT PANEL SCHEDULE AND SITE DRAWINGS. <br />13. ALL TRENCHES IN COMPOUND TO BE HAND DUG. <br />14. CONTRACTOR TO VERIFY HANDHOLE AND/OR PULL BOXES REQUIREMENTS WITH SELECTED FIBER PROVIDER <br />PRIOR TO CONSTRUCTION OF TRENCH. <br />8' 4' 0 8' 1 E <br />ELECTRICAL NOTES NO SCALE 2 <br />d..*.sh <br />wirelessry <br />5701 SOUTH SANTA FE DRIVE <br />LITTLETON, CO 80120 <br />TOWER ING PROFESSIONALS <br />326 D. RALEIGH, NC <br />27603 FI E: (919) 661-6351 <br />A <br />N <br />50257 <br />�131ST <br />_v—fi 8, 2022 <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE <br />DIRECTION OF A LICENSED PROFESSIONAL <br />ENGINEER, TO ALTER THIS DOCUMENT. <br />DRAWN BY: <br />CHECKED BY:APPROVED <br />BY: <br />CDK <br />CP <br />CP <br />RFDS REV #: TBD <br />CONSTRUCTION <br />DOCUMENTS <br />SUBMITTALS <br />REV <br />DATE <br />DESCRIPTION <br />A <br />08-05-21 <br />PRELIMINARY <br />B <br />12-21-21 <br />PRELIMINARY <br />C <br />01-18-22 <br />PRELIMINARY <br />0 <br />03-08-22 <br />CONSTRUCTION <br />A&E PROJECT NUMBER <br />147003 <br />DISH WIRELESS, L.L.C. <br />PROJECT INFORMATION <br />SESEA00361C <br />9610 19TH AVENUE SE <br />EVERETT, WA 98208 <br />SHEET TITLE <br />ELECTRICAL/FIBER ROUTE <br />PLAN AND NOTES <br />SHEET NUMBER <br />E-1 <br />