CARLON EXPANSION FITTINGS <br />COUPLING END <br />PART# <br />MALE TERMINAL <br />ADAPTER END <br />PART# <br />SIZE <br />STD <br />CTN <br />QTY. <br />TRAVEL <br />LENGTH <br />E945D <br />E945DX <br />1/2" <br />20 <br />4" <br />E945E <br />E945EX <br />3/4" <br />15 <br />4" <br />E945F <br />E945FX <br />1" <br />10 <br />4" <br />E945G <br />E945GX <br />1 1/4" <br />5 <br />4" <br />E945H <br />E945HX <br />1 1/2" <br />5 <br />4" <br />E945J <br />E945JX <br />2" <br />15 <br />8" <br />E945K <br />E945KX <br />2 1/2" <br />10 <br />8" <br />E945L <br />E945LX <br />3" <br />10 <br />8" <br />E945M <br />E945MX <br />3 1/2" <br />5 <br />8" <br />E945N <br />E945NX <br />4" <br />5 <br />8" <br />E945P <br />E945PX <br />5" <br />1 <br />8" <br />E945R <br />E945RX <br />6" <br />1 <br />8" <br />EXPANSION JOINT DETAIL <br />VARIES PER <br />PART NUMBER <br />SLIP JOINT <br />(SEE CHART FOR <br />r <br />PART NUMBER) <br />NOTE: <br />CONTRACTOR TO INSTALL EXPANSION FITTING <br />SLIP JOINT AT METER CENTER CONDUIT <br />TERMINATION, AS PER LOCAL UTILITY POLICY, <br />ORDINANCE AND/OR SPECIFIED REQUIREMENT <br />NO SCALE 1 <br />SEE TRENCHING NOTE 1 <br />DISH WIRELESS, L.L.C. <br />DISH WIRELESS, L.L.C. <br />FIBER DISTRIBUTION PANEL. <br />PROVIDES 12AWG <br />Q Q Q <br />TRENCHING NOTES <br />-BACKFILL <br />WORK SPECIFICATIONS PER SITE <br />WIRE (6' TAIL) <br />PROPOSED DISH WIRELESS, L.L.C. <br />(SEE GENERAL NOTES) <br />TELCO FIBER ENCLOSURE <br />1. CONTRACTOR SHALL RESTORE THE <br />TRENCH TO ITS ORIGINAL <br />SLOPE TO SUIT SOIL <br />n <br />CONDITIONS BY EITHER SEEDING <br />CONDITION IN ACCORDANCE <br />u <br />OR SODDING GRASS AREAS, OR <br />WITH LOCAL REGULATIONS <br />SEE TRENCHING NOTE 2 <br />PROPOSED DISH WIRELESS, <br />REPLACING ASPHALT OR CONCRETE <br />L.L.C. UNISTRUT <br />AREAS TO ITS ORIGINAL CROSS <br />�j�/w <br />0000mo <br />SECTION. <br />/\ <br />DISH WIRELESS, L.L.C. FIBER <br />2. TRENCHING SAFETY; INCLUDING, <br />o <br />\/\ <br />/� <br />o U <br />JUMPER TO CABINET WILL <br />BUT NOT LIMITED TO SOIL <br />NEED TO BE TERMINATED BY <br />FIBER PROVIDER OTHER <br />CLASSIFICATION, SLOPING, AND <br />`/\ <br />3 <br />PROPOSED DISH <br />D <br />SIDE OF BULKHEAD/LC TO LC <br />SHORING, SHALL BE GOVERNED <br />1= Z <br />/ <br />�j� <br />i� <br />WIRELESS, L.L.C. <br />CONNECTOR WHERE CIRCUIT <br />BY THE CURRENT OSHA <br />UJ a <br />\ <br />o : N <br />10 AMP DISTRIBUTION <br />BREAKER <br />IS TERMINATED. <br />TRENCHING AND EXCAVATION <br />SAFETY STANDARDS. <br />< o <br />o <br />M o <br />3. ALL CONDUITS SHALL BE <br />F z <br />w w <br />j <br />- - <br />o <br />IN IN O <br />PROPOSED FIBER PROVIDER <br />INSTALLED IN COMPLIANCE WITH <br />> N <br />/ <br />FIBER LATERAL FROM RIGHT <br />/ <br />PROPOSED DISH WIRELESS, L.L.C. <br />Q Q <br />THE CURRENT NATIONAL <br />/� /. <br />UTILITY WARNING TAPE <br />12 AWG WIRE <br />\ <br />OF WAY TO STREET, <br />ELECTRIC CODE (NEC) <br />NEC OR AS <br />PROPOSED DISH WIRELESS, L.L.C. <br />\ <br />TERMINATED TO FDP <br />REQUIRED BY THE LOCAL <br />SAND BEDDING PER SITE <br />1-1/2" POWER FROM CABINET <br />PROPOSED DISH WIRELESS, L.L.C. <br />JURISDICTION, WHICHEVER IS <br />WORK SPECIFICATIONS <br />DISH WIRELESS, L.L.C. INSTALLS <br />1-1/2" FIBER TO CABINET <br />THE MOST STRINGENT. <br />1-1/2" CONDUITS FOR POWER <br />IVPROPOSED <br />DISH WIRELESS, <br />AND FIBER TO CABINET <br />L.L.C. 2" CONDUIT FROM <br />COMMERCIAL FIBER VAULT <br />TYPICAL UNDERGROUND TRENCH <br />DETAIL <br />NO SCALE <br />2 <br />DARK TELCO BOX <br />- INTERIOR WIRING LAYOUT <br />I NO SCALE <br />3 <br />NOTE: FIBER PROVIDER <br />PROPOSED FIBER <br />WILL NEED TO PROVIDE AN <br />PROPOSED DISH WIRELESS, <br />NID, IF REQUIRED <br />ADDITIONAL 5FT UNISTRUT, <br />2 U-BOLTS WITH 4 NUTS, <br />L.L.C. UNISTRUT <br />IN THE EVENT THE <br />BRACKET SPACING DOESN'T <br />LINE UP WITH CURRENT <br />SPACING BELOW <br />PROPOSED FIBER PROVIDER <br />IN IN OUT <br />1-1/4" FLEX CONDUITS <br />FIBER PROVIDER TO TERMINATE <br />FIBER PROVIDER TO PUNCH TOP OF <br />POWER TO FIBER PROVIDER NID <br />TELCO BOX OF NID ENCLOSURE AND <br />PROPOSED DISH WIRELESS, <br />INSTALL 1-1/4" LIQUID TIGHT <br />L.L.C. 12 AWG WIRE (6' TAIL <br />CONNECTORS, UL LISTED, NYLON <br />MATERIAL, WITH 0-RING GASKET <br />FIBER PROVIDER TO INSTALL <br />1-1/4" FLEX CONDUITS BETWEEN <br />PROPOSED DISH WIRELESS, L.L.C. <br />�� <br />FDP TELCO BOX & NID <br />10 AMP DISTRIBUTION BREAKER <br />PROPOSED DISH WIRELESS, L.L.C. <br />TELCO FIBER ENCLOSURE <br />PROPOSED DISH WIRELESS, L.L.C. <br />12 AWG WIRE <br />PROPOSED DISH WIRELESS, L.L.C. <br />1-1/2" FIBER TO CABINET <br />T <br />PROPOSED DISH WIRELESS, L.L.C. <br />IN <br />IN <br />0 <br />PROPOSED DISH WIRELESS, <br />0 0 <br />1-1/2" POWER FROM CABINET <br />L.L.C. 2" CONDUIT FROM <br />COMMERCIAL FIBER VAULT <br />LIT TELCO BOX - INTERIOR <br />WIRING LAYOUT <br />(OPTIONAL <br />I NO SCALE <br />4 <br />NOT USED <br />NO SCALE <br />5 <br />NOT USED <br />NO SCALE <br />6 <br />NOT USED <br />NO SCALE 7 <br />NOT USED I NO SCALE 18 I NOT USED I NO SCALE I 9 I <br />d..*.sh <br />wireless- <br />5701 SOUTH SANTA FIE DRIVE <br />LITTLETON, CO 80120 <br />TOWER GI ERI G PROFESSIONALS <br />326 Y R RALEIGH, INC <br />2760 FF 19) 661-6351 <br />-4 IV <br />F A <br />c <br />50257 <br />NA <br />.."h 8, 2022 <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE <br />DIRECTION OF A LICENSED PROFESSIONAL <br />ENGINEER, TO ALTER THIS DOCUMENT. <br />DRAWN BY: <br />CHECKED BY:APPROVED <br />BY: <br />CDK I <br />CP <br />I CP <br />REDS REV #: TBD <br />CONSTRUCTION <br />DOCUMENTS <br />SUBMITTALS <br />REV <br />DATE <br />DESCRIPTION <br />,1 <br />08-05-21 <br />PRELIMINARY <br />B <br />12-21-21 <br />PRELIMINARY <br />C <br />01-18-22 <br />PRELIMINARY <br />0 <br />03-08-22 <br />CONSTRUCTION <br />A&E PROJECT NUMBER <br />147003 <br />DISH WIRELESS, L.L.C. <br />PROJECT INFORMATION <br />SESEA00361C <br />9610 19TH AVENUE SE <br />EVERETT, WA 98208 <br />SHEET TITLE <br />ELECTRICAL <br />DETAILS <br />SHEET NUMBER <br />E-2 <br />