My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
9610 19TH AVE SE DISH WIRELESS 2023-11-01
>
Address Records
>
19TH AVE SE
>
9610
>
DISH WIRELESS
>
9610 19TH AVE SE DISH WIRELESS 2023-11-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/1/2023 8:12:09 AM
Creation date
7/27/2023 7:49:57 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9610
Tenant Name
DISH WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PROPOSED POWER PROTECTIVE CABINET <br />UTILITY SERVICE ENTRANCE 120/24OV, 1 PH, SERVICE RATED, <br />UOVERALL ILL LISTED POWER CENTER, <br />1TILITY VAC 1PH N3R, 65K/10K AIC <br />BACKUP MAIN BREAKER WITH <br />EXISTING TRANSFORMER <br />GENERATOR 200A 200A INTERLOCKED GENERATOR <br />(SIZE & NUMBER UNKNOWN) <br />CAMLOCK FEED, 200A 65K AIC <br />GEN PLUG <br />PROPOSED 3" U.G. POWER <br />N <br />CONDUIT AND (3) #3/0 CU <br />SURGE SUPPRESSION <br />CONDUCTORS PER UTILITY <br />DEVICE 100KA SAD/MOV <br />SPECS <br />01 02 <br />GFCI 15A 30A PROPOSED 2 #10, 1 #10 CU GND. <br />200A, 240V iPH <br />03 04 <br />M UTILITY METER <br />15A <br />O5 06 <br />SPACE 07 08 30A PROPOSED 2 #10 <br />PROPOSED 200A <br />SPACE <br />DISCONNECT SERVICE RATED. <br />09 10 <br />MOUNTED TO H—FRAME <br />SPACE 30A PROPOSED 2 #10, 1 #10 CU CND. <br />II 12 <br />GROUNDING ELECTRODE <br />SPACE <br />CONDUCTOR #4 AWG BARE <br />I3 14 <br />PROPOSED 2 #10 <br />TINNED SOLID COPPER <br />(3) 3/0 WITH #6 GROUND <br />SPACE 30A <br />15 16 <br />IN 3" SCH 40 CONDUIT <br />SPACE <br />7 8 <br />SERVICE ENTRANCE <br />GROUND ROD <br />SPACE 19 20 —SPACE <br />PROPOSED 2 #10, 1 #10 CU CND. <br />(2) PROPOSED <br />0,75" EMT CONDUITS <br />(1) PROPOSED <br />0.5" EMT CONDUIT <br />CHARLES NETWORK CABINET <br />FOR RECTIFIER 1 <br />FOR RECTIFIER 2 <br />FOR RECTIFIER 3 <br />FOR RECTIFIER 4 <br />FOR CONVENIENCE OUTLET <br />NOTE: <br />BRANCH CIRCUIT WIRING SUPPLYING RECTIFIERS ARE TO BE RATED UL1015, 105'C, 600V, AND PVC INSULATED, IN THE SIZES SHOWN <br />IN THE ONE —LINE DIAGRAM. CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR THWN-2 FOR CONVENIENCE OUTLET BRANCH CIRCUIT. <br />BREAKERS REQUIRED: <br />(4) 30A, 2P BREAKER — SQUARE D P/N:00230 <br />(1) 15A, 1P BREAKER — SQUARE D P/N:00115 <br />NOTES <br />THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED SHORT CIRCUIT <br />CALCULATIONS AND THE AIC RATINGS FOR EACH DEVICE IS ADEQUATE TO PROTECT THE <br />EQUIPMENT AND THE ELECTRICAL SYSTEM. <br />THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED VOLTAGE DROP <br />CALCULATIONS AND ALL BRANCH CIRCUIT AND FEEDERS COMPLY WITH THE NEC <br />(LISTED ON T-1) ARTICLE 210.19(A)(1) FPN NO. 4. <br />THE (2) CONDUITS WITH (4) CURRENT CARRYING CONDUCTORS EACH, SHALL APPLY <br />THE ADJUSTMENT FACTOR OF 80% PER 2014/17 NEC TABLE 310.15(B)(3)(a) OR <br />2020 NEC TABLE 310.15(C)(1) FOR UL1015 WIRE. <br />#12 FOR 15A-20A/1P BREAKER: 0.8 x 30A = 24.OA <br />#10 FOR 25A-30A/2P BREAKER: 0.8 x 40A = 32.OA <br />#8 FOR 35A-40A/2P BREAKER: 0.8 x 55A = 44.OA <br />#6 FOR 45A-60A/2P BREAKER: 0.8 x 75A = 60.OA <br />CONDUIT SIZING: AT 40% FILL PER NEC CHAPTER 9, TABLE 4, ARTICLE 358. <br />0.5" CONDUIT — 0.122 SQ. IN AREA <br />0.75" CONDUIT — 0.213 SQ. IN AREA <br />2.0 CONDUIT — 1.316 SO. IN AREA <br />3.0 CONDUIT — 2.907 SO. IN AREA <br />CABINET CONVENIENCE OUTLET CONDUCTORS (1 CONDUIT): USING THWN-2, CU. <br />#10 — 0.0211 SO. IN X 2 = 0.0422 SO. IN <br />#10 — 0.0211 SQ. IN X 1 = 0.0211 SQ. IN <GROUND <br />TOTAL = 0.0633 SQ. IN <br />0.5" EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (3) WIRES, <br />INCLUDING GROUND WIRE, AS INDICATED ABOVE. <br />RECTIFIER CONDUCTORS (2 CONDUITS): USING UL1015, CU. <br />#10 — 0.0266 SO. IN X 4 = 0.1064 SQ. IN <br />#10 — 0.0082 SQ. IN X 1 = 0.0082 SQ. IN <BARE GROUND <br />TOTAL = 0.1146 SQ. IN <br />0.75" EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (5) WIRES, <br />INCLUDING GROUND WIRE, AS INDICATED ABOVE. <br />PPC FEED CONDUCTORS (1 CONDUIT): USING THWN, CU. <br />3/0 — 0.2679 SO. IN X 3 = 0.8037 SQ. IN <br />#6 — 0.0507 SO. IN X 1 = 0.0507 SQ. IN <GROUND <br />TOTAL = 0.8544 SQ. IN <br />3.0" SCH 40 PVC CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (4) WIRES, <br />INCLUDING GROUND WIRE, AS INDICATED ABOVE. <br />I PPC ONE -LINE DIAGRAM I NO SCALE 11 1 <br />PROPOSED CHARLES PANEL SCHEDULE <br />VOLT AMPS <br />VOLT AMPS <br />LOAD SERVED <br />(WATTS) <br />TRIP <br />CKTPHASE <br />CKTTRIP <br />(WATTS) <br />LOAD SERVED <br />L1 L2 <br />L1 L2 <br />PPC GFCI OUTLET <br />18(U <br />i5A <br />1 <br />A <br />2 <br />2880 <br />ABB/GE INFINITY <br />CHARLES GFCI OUTLET <br />180 <br />15A <br />3 <br />B <br />4 <br />30A <br />2880 <br />RECTIFIER 1 <br />—SPACE— <br />5 <br />A <br />6 <br />30A <br />2880 <br />ABB/GE INFINITY <br />—SPACE— <br />7 <br />B <br />8 <br />2880 <br />RECTIFIER 2 <br />—SPACE— <br />9 <br />A <br />10 <br />30A <br />2880 <br />ABB/GE INFINITY <br />—SPACE— <br />11 <br />B <br />12 <br />2-8-8-01 <br />RECTIFIER 3 <br />—SPACE— <br />13 <br />A <br />14 <br />30A <br />2880 <br />2880 <br />ABB/GE INFINITY <br />RECTIFIER 4 <br />—SPACE— <br />15 <br />B <br />16 <br />—SPACE— <br />17 <br />A <br />18 <br />—SPACE- <br />-SPACE— <br />19 <br />B <br />20 <br />—SPACE- <br />-SPACE— <br />21 <br />A <br />22 <br />—SPACE- <br />-SPACE— <br />23 <br />B <br />24 <br />—SPACE— <br />VOLTAGE AMPS <br />180 180 <br />11520 <br />11520 <br />200A MCB, 1�, 24 SPACE, <br />120/240V <br />L1 <br />L2 <br />ME RATING: 65,000 AIC <br />11700 <br />11700 <br />VOLTAGE AMPS <br />98 <br />1 98 <br />AMPS <br />98 <br />MAX AMPS <br />123 <br />MAX 125% <br />PANEL SCHEDULE <br />NO SCALE 2 <br />NOT USED <br />NO SCALE 3 <br />d..*.sh <br />wireless- <br />5701 SOUTH SANTA FIE DRIVE <br />LITTLETON, CO 80120 <br />i <br />1� <br />TOWER G PROFESSIONALS <br />aNG <br />326 RALEIGH, NC <br />27603 19) 661-6351 <br />1 ' L `_ <br />F ASy�� d� <br />A. <br />� , 2 <br />h <br />h � <br />Ofi 50257� <br />� <br />�0 <br />AL�Uti. <br />March 8,, 2022 <br />IT IS A VIOLATION OF LAW FOR ANY PERSON, <br />UNLESS THEY ARE ACTING UNDER THE <br />DIRECTION OF A LICENSED PROFESSIONAL <br />ENGINEER, TO ALTER THIS DOCUMENT. <br />DRAWN BY: <br />CHECKED BY:APPROVED <br />BY: <br />CDK I <br />CP <br />I CP <br />REDS REV #: TBD <br />CONSTRUCTION <br />DOCUMENTS <br />SUBMITTALS <br />REV <br />DATE <br />DESCRIPTION <br />,1 <br />08-05-21 <br />PRELIMINARY <br />B <br />12-21-21 <br />PRELIMINARY <br />C <br />01-18-22 <br />PRELIMINARY <br />0 <br />03-08-22 <br />CONSTRUCTION <br />A&E PROJECT NUMBER <br />147003 <br />DISH WIRELESS, L.L.C. <br />PROJECT INFORMATION <br />SESEA00361C <br />9610 19TH AVENUE SE <br />EVERETT, WA 98208 <br />SHEET TITLE <br />ELECTRICAL ONE -LINE, FAULT <br />CALCS & PANEL SCHEDULE <br />SHEET NUMBER <br />E-3 <br />