9606 19TH AVE SE DISH WIRELESS 2023-08-01
>
Address Records
>
19TH AVE SE
>
9606
>
DISH WIRELESS
>
9606 19TH AVE SE DISH WIRELESS 2023-08-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2023 2:56:21 PM
Creation date
7/27/2023 7:50:43 AM
Metadata
Fields
Template:
Address Document
Street Name
19TH AVE SE
Street Number
9606
Tenant Name
DISH WIRELESS
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NOTES <br /> THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED SHORT CIRCUIT d ..*.sh PROPOSED POWER PROTECTIVE CABINET CHARLES NETWORK CABINET CALCULATIONS AND THE AIC RATINGS FOR EACH DEVICE IS ADEQUATE TO PROTECT THE <br /> UTILITY SERVICE ENTRANCE 120/24OV, 1 PH, SERVICE RATED, EQUIPMENT AND THE ELECTRICAL SYSTEM. <br /> 120/240 VAC 1PH OVERALL UL LISTED POWER CENTER, <br /> N3R, 65K/10K AIC THE ENGINEER OF RECORD HAS PERFORMED ALL REQUIRED VOLTAGE DROP <br /> CALCULATIONS AND ALL BRANCH CIRCUIT AND FEEDERS COMPLY WITH THE NEC <br /> BACKUP MAIN BREAKER WITH (LISTED ON T-1) ARTICLE 210.19(A)(1) FPN NO. 4. <br /> EXISTING TRANSFORMER GENERATOR 200A 200A INTERLOCKED GENERATOR <br /> (SIZE & NUMBER UNKNOWN) CAMLOCK FEED, 200A 65K AIC (2) PROPOSED <br /> GEN PLUG 0.75" EMT CONDUITS THE (2) CONDUITS WITH (4) CURRENT CARRYING CONDUCTORS EACH, SHALL APPLY wireless,. <br /> PROPOSED 3" U.G. POWER THE ADJUSTMENT FACTOR OF 80% PER 2014/17 NEC TABLE 310.15(B)(3)(a) OR <br /> CONDUIT AND (3) #3/0 CU SURGE SUPPRESSION 2020 NEC TABLE 310.15(C)(1) FOR UL1015 WIRE. <br /> CONDUCTORS PER UTILITY DEVICE 100KA SAD/MOV <br /> SPECS #12 FOR 15A-20A/1P BREAKER: 0.8 x 30A = 24.OA 5701 SOUTH SANTA FE DRIVE <br /> G FCI 15A 01 02 30A PROPOSED 2 #10, 1 #10 CU GND. #10 FOR 25A-30A/2P BREAKER: 0.8 x 40A = 32.OA LITTLETON, CO 80120 <br /> 200A, 240V 1PH 03 04 FOR RECTIFIER 1 #8 FOR 35A-40A/2P BREAKER: 0.8 x 55A = 44.OA <br /> M UTILITY METER 15A <br /> #6 FOR 45A-60A/2P BREAKER: 0.8 x 75A = 60.OA <br /> O5 06 <br /> SPACE 07 06 30A PROPOSED 2 10 FOR RECTIFIER 2 CONDUIT SIZING: AT 40% FILL PER NEC CHAPTER 9, TABLE 4, ARTICLE 358. <br /> PROPOSED 200A 0.5" CONDUIT - 0.122 SQ. IN AREA ,y� <br /> SPACE 0.75" CONDUIT - 0.213 SQ. IN AREA <br /> DISCONNECT SERVICE RATED. 09 10 i1 <br /> MOUNTED TO H-FRAME SPACE 30A PROPOSED 2 #10, 1 #10 CU GN D. 2.0" CONDUIT - 1.316 SQ. IN AREA <br /> 11 12 FOR RECTIFIER 3 3.0" CONDUIT - 2.907 SQ. IN AREA �� <br /> GROUNDING ELECTRODE SPACE �0 <br /> CONDUCTOR #4 AWG BARE 13 14 CABINET CONVENIENCE OUTLET CONDUCTORS (1 CONDUIT): USING THWN-2, CU. <br /> TINNED SOLID COPPER SPACE 30A PROPOSED 2 #10 <br /> (3) 3/0 WITH #6 GROUND 15 16 FOR RECTIFIER 4 � <br /> llk <br /> IN 3" SCH 40 CONDUIT #10 - 0.0211 SQ. IN X 2 = 0.0422 SQ. IN <br /> SPACE 18 #10 - 0.0211 SQ. IN X 1 = 0.0211 SQ. IN <GROUND <br /> 17 <br /> SERVICE ENTRANCE SPACE SPACE TOTAL = 0.0633 SQ. IN <br /> GROUND Roo 19 20 (1) PROPOSED TOWER aNG G PROFESSIONALS <br /> SPACE SPACE 0.5" EMT CONDUIT 0.5 EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (3) WIRES, 326 RALEIGH, NC <br /> SPACE SPACE INCLUDING GROUND WIRE, AS INDICATED ABOVE. 27603 19) 661-6351 <br /> 23 24 <br /> SPACE SPACE RECTIFIER CONDUCTORS (2 CONDUITS): USING UL1015, CU. <br /> PROPOSED 2 #10, 1 #10 CU CND. FOR CONVENIENCE OUTLET #10 - 0.0266 SQ. IN X 4 = 0.1064 SQ. IN <br /> #10 - 0.0082 SQ. IN X 1 = 0.0082 SQ. IN <BARE GROUND �R A ^ <br /> NOTE: TOTAL = 0.1146 SQ. IN F ASy�� v� <br /> BRANCH CIRCUIT WIRING SUPPLYING RECTIFIERS ARE TO BE RATED UL1015, 105'C, 600V, AND PVC INSULATED, IN THE SIZES SHOWN 0.75" EMT CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (5) WIRES, A, <br /> IN THE ONE DIAGRAM. CONTRACTOR MAY SUBSTITUTE UL1015 WIRE FOR THWN-2 FOR CONVENIENCE OUTLET BRANCH CIRCUIT. INCLUDING GROUND WIRE, AS INDICATED ABOVE. r <br /> h 2 <br /> BREAKERS REQUIRED: PPC FEED CONDUCTORS (1 CONDUIT): USING THWN, CU. h <br /> (4) 30A, 2P BREAKER - SQUARE D P/N:00230 <br /> (1) 15A, 1P BREAKER - SQUARE D P/N:00115 3/0 - 0.2679 SQ. IN X 3 = 0.8037 SQ. IN <br /> #6 - 0.0507 SQ. IN X 1 = 0.0507 SQ. IN <GROUND <br /> 1 <br /> TOTAL = 0.8544 SQ. IN 50257 ^Y <br /> ` <br /> 3.0" SCH 40 PVC CONDUIT IS ADEQUATE TO HANDLE THE TOTAL OF (4) WIRES, ��GISTv4�� <br /> INCLUDING GROUND WIRE, AS INDICATED ABOVE. �,�IONAL <br /> PPC ONE-LINE DIAGRAM NO SCALE March 8,,2022 <br /> IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> UNLESS THEY ARE ACTING UNDER THE <br /> DIRECTION OF A LICENSED PROFESSIONAL <br /> ENGINEER,TO ALTER THIS DOCUMENT. <br /> DRAWN BY: CHECKED BY:APPROVED BY: <br /> CDK I CP I CP <br /> RFDS REV #: TBD <br /> CONSTRUCTION <br /> DOCUMENTS <br /> PROPOSED CHARLES PANEL SCHEDULE SUBMITTALS <br /> VOLT AMPS VOLT AMPS REV DATE DESCRIPTION <br /> LOAD SERVED (WATTS) TRIP CKTPHASE CKTTRIP (WATTS) LOAD SERVED <br /> L1 L2 L1 L2 A 08-05-21 PRELIMINARY <br /> PPC GFCI OUTLET 180 IbA 1 A 2 2880 ABB/GE INFINITY B 12-21-21 PRELIMINARY <br /> CHARLES GFCI OUTLET 180 15A 3 B 4 30A 2880 RECTIFIER 1 <br /> -SPACE- 5 A 6 30A 2880 ABB/GE INFINITY C 01-18-22 PRELIMINARY <br /> -SPACE- 7 B 8 2880 RECTIFIER 2 0 03-08-22 CONSTRUCTION <br /> -SPACE- 9A 10 2880 ABB/GE INFINITY <br /> -SPACE- 11 B 12 30A 2-8-8-01 RECTIFIER 3 <br /> -SPACE- 13 A 14 30A 2880 ABB/GE INFINITY <br /> -SPACE- 15 B 16 2880 RECTIFIER 4 <br /> -SPACE- 17A 181 SPACE- <br /> -SPACE- 19 B 20 -SPACE- A&E PROJECT NUMBER <br /> -SPACE- 21A 22 -SPACE- <br /> -SPACE- 23 B 24 -SPACE- 147003 <br /> VOLTAGE AMPS 180 180 1 11520 1 11520 <br /> 200A MCB, 1�, 24 SPACE, 120/240VL1 L2 <br /> MB RATING: 65,000 AIC 11700 11700 VOLTAGE AMPS DISH WIRELESS, L.L.C. <br /> 98 98 AMPS PROJECT INFORMATION <br /> 98 1 MAX AMPS <br /> 123 IMAX 125% <br /> SESEA00361C <br /> 9610 19TH AVENUE SE <br /> EVERETT, WA 98208 <br /> SHEET TITLE <br /> ELECTRICAL ONE-LINE, FAULT <br /> CALCS & PANEL SCHEDULE <br /> SHEET NUMBER <br /> E-3 <br /> PANEL SCHEDULE NO SCALE `Z NOT USED NO SCALE 3 <br />