Laserfiche WebLink
PROPOSED BUSS ■ EXOTHERMIC CONNECTION TEST GROUND ROD WITH <br /> BAR INSULATORS PROPOSED 4"x12"x1/4" TINNED 10� INSPECTION SLEEVE <br /> TEST WELL _ COPPER GROUND BUSSBAR d ..*.sh T� — — � \t` —♦— t — — —� • ■ MECHANICAL CONNECTION #2 AWG STRANDED & INSULATED � <br /> / 1r 1 GROUND BUS BAR <br /> I \ I #2 AWG SOLID COPPER TINNED <br /> OGROUND ROD <br /> A BUSS BAR INSULATOR wireless- <br /> PLATFORM <br /> PROPOSED EQUIPMENT \ — / <br /> PLATFORM TO PROPOSED // <br /> GROUNDING ELECTRODE - 5701 SOUTH SANTA FE DRIVE <br /> SYSTEM (TYP. 4) _______ - GROUNDING LEGEND <br /> LITTLETON, CO 80120 <br /> BOND H-FRAME POST TO I6 ° ° EXISTING TOWER GROUND <br /> UNI-STRUT (TYP.) j n RING (FIELD VERIFY) 1. GROUNDING IS SHOWN DIAGRAMMATICALLY ONLY. <br /> BOND ICE <br /> POSTS BRIDGE <br /> TO <br /> 2. CONTRACTOR SHALL GROUND ALL EQUIPMENT AS A COMPLETE SYSTEM. GROUNDING SHALL BE IN Ryl <br /> (TYPGROU ALL ND RPOSTS)ING ND(s) COMPLIANCE WITH NEC SECTION 250 AND DISH\ REQUIREMENTS AND MANUFACTURER'S SPECIFICATWLESS, L L.C. GROUNDING AND BONDING <br /> SPECIFICATIONS.EXISTING MONOPOLE <br /> #2 AWG BURIED GROUND / / °, \ 3. ALL GROUND CONDUCTORS SHALL BE COPPER; NO ALUMINUM CONDUCTORS SHALL BE USED. <br /> RING 30" BELOW GRADE <br /> � OO <br /> #2 TINNED SOLID IN 1/2" P O O `I GROUNDING KEY NOTES TOWER GIN ER G PROFESSIONALS <br /> MIN. LIQUID TIGHT CONDUIT °" 326 YO R RALEIGH, NC <br /> FROM 24" BELOW GRADE 27603 FI 919) 661-6351 <br /> TO WITHIN 3" TO 6" OF a <br /> CAD—WELD TERMINATION - 0 O EXTERIOR GROUND RING: #2 AWG SOLID COPPER, BURIED AT A DEPTH OF AT LEAST 30 INCHES BELOW <br /> POINT. EXPOSED END OF - / GRADE, OR 6 INCHES BELOW THE FROST LINE AND APPROXIMATELY 24 INCHES FROM THE EXTERIOR WALL <br /> THE LIQUID TIGHT CONDUIT ° — OR FOOTING. <br /> MUST BE SEALED WITH <br /> SILICONE CAULK. (TYR)WITH / — = Y\ `—� \ / B TOWER GROUND RING: THE GROUND RING SYSTEM SHALL BE INSTALLED AROUND AN ANTENNA TOWER'S LEGS, A A. <br /> O AND/OR GUY ANCHORS. WHERE SEPARATE SYSTEMS HAVE BEEN PROVIDED FOR THE TOWER AND THElYf� <br /> BUILDING, AT LEAST TWO BONDS SHALL BE MADE BETWEEN THE TOWER RING GROUND SYSTEM AND THE 'O ASH/ v� <br /> BUILDING RING GROUND SYSTEM USING MINIMUM #2 AWG SOLID COPPER CONDUCTORS. <br /> x fp <br /> — OINTERIOR GROUND RING: #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTOR EXTENDED AROUND THE y , <br /> PERIMETER OF THE EQUIPMENT AREA. ALL NON-TELECOMMUNICATIONS RELATED METALLIC OBJECTS FOUND <br /> BOND EQUIPMENT AS WITHIN A SITE SHALL BE GROUNDED TO THE INTERIOR GROUND RING WITH #6 AWG STRANDED GREEN <br /> REQUIRED BY MANUFACTURER INSULATED CONDUCTOR. <br /> 1 <br /> PROPOSED EQUIPMENT GROUND RING TO D BOND TO INTERIOR GROUND RING: #2 AWG SOLID TINNED COPPER WIRE PRIMARY BONDS SHALL BE G <br /> EXISTING TOWER GROUND RING (TOTAL 2) O PROVIDED <br /> AT LEAST AT FOUR POINTS ON THE INTERIOR GROUND RING, LOCATED AT THE CORNERS OF THE r.. �F5025750257 �Gti <br /> O GROUND ROD: UL LISTED COPPER CLAD STEEL. MINIMUM 1/2" DIAMETER BY EIGHT FEET LONG. GROUND ,SIGNAL V <br /> TYPICAL EQUIPMENT GROUNDING PLAN NO SCALE 1 E RODS SHALL BE INSTALLED WITH INSPECTION SLEEVES. GROUND RODS SHALL BE DRIVEN TO THE DEPTH OF <br /> GROUND RING CONDUCTOR. <br /> March 8,2022 <br /> NOTEF CELL REFERENCE GROUND BAR: POINT OF GROUND REFERENCE FOR ALL COMMUNICATIONS EQUIPMENT IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> O FRAMES. ALL BONDS ARE MADE WITH #2 AWG UNLESS NOTED OTHERWISE STRANDED GREEN INSULATED UNLESS THEY ARE ACTING UNDER THE <br /> COPPER CONDUCTORS. BOND TO GROUND RING WITH (2) #2 SOLID TINNED COPPER CONDUCTORS. DIRECTION OF A LICENSED PROFESSIONAL <br /> ANTENNAS AND OVP SHOWN ARE GENERIC AND NOT ENGINEER,TO ALTER THIS DOCUMENT. <br /> REFERENCING TO A SPECIFIC MANUFACTURER. THIS <br /> LAYOUT IS FOR REFERENCE ONLY. O HATCH PLATE GROUND BAR: BOND TO THE INTERIOR GROUND RING WITH TWO #2 AWG STRANDED GREEN DRAWN BY: CHECKED BY:APPROVED BY: <br /> INSULATED COPPER CONDUCTORS. WHEN A HATCH-PLATE AND A CELL REFERENCE GROUND BAR ARE BOTH <br /> PRESENT, THE CRGB MUST BE CONNECTED TO THE HATCH-PLATE AND TO THE INTERIOR GROUND RING CDK CP CP <br /> USING (2) TWO #2 AWG STRANDED GREEN INSULATED COPPER CONDUCTORS EACH. <br /> REDS REV #: TBD <br /> EXTERIOR CABLE <br /> ND <br /> ATED <br /> THE <br /> E TO <br /> CELL <br /> TE <br /> G. <br /> O O GROUNDECTION RING WITH <br /> PORT <br /> WG SOLID TIIN�NEDGCOPP RTCONDUCTORSGWITHH ANEEXOTHERIMC WELD INAND <br /> OND CONSTRUCTION <br /> TELCO GROUND BAR: BOND TO BOTH CELL REFERENCE GROUND BAR OR EXTERIOR GROUND RING. DOCUMENTS <br /> i <br /> %% O FRAME BONDING: THE BONDING POINT FOR TELECOM EQUIPMENT FRAMES SHALL BE THE GROUND BUS THAT SUBMITTALS <br /> IS NOT ISOLATED FROM THE EQUIPMENTS METAL FRAMEWORK. REV DATE DESCRIPTION <br /> o� O INTERIOR UNIT BONDS: METAL FRAMES, CABINETS AND INDIVIDUAL METALLIC UNITS LOCATED WITH THE AREA A 08-05-21 PRELIMINARY <br /> OF THE INTERIOR GROUND RING REQUIRE A #6 AWG STRANDED GREEN INSULATED COPPER BOND TO THE B 12-21-21 PRELIMINARY <br /> INTERIOR GROUND RING. C 01-18-22 PRELIMINARY <br /> FENCE AND GATE GROUNDING: METAL FENCES WITHIN 7 FEET OF THE EXTERIOR GROUND RING OR OBJECTS 0 03-08-22 CONSTRUCTION <br /> I I BONDED TO THE EXTERIOR GROUND RING SHALL BE BONDED TO THE GROUND RING WITH A #2 AWG SOLID <br /> PROPOSED 4"x6"x1/4" TINNED TINNED COPPER CONDUCTOR AT AN INTERVAL NOT EXCEEDING 25 FEET. BONDS SHALL BE MADE AT EACH <br /> I \ COPPER SECTOR GROUND GATE POST AND ACROSS GATE OPENINGS. <br /> PROPOSED UPPER I \ BUSSBAR (TYP OF 3) <br /> TOWER GROUND BAR 1 I EXTERIOR UNIT BONDS: METALLIC OBJECTS, EXTERNAL TO OR MOUNTED TO THE BUILDING, SHALL BE BONDED <br /> \ A&E PROJECT NUMBER <br /> PROPOSED #2 AWG STRANDED O TO THE EXTERIOR GROUND RING. USING #2 TINNED SOLID COPPER WIRE <br /> COPPER GREEN INSULATED (TYR) 147003 <br /> ICE BRIDGE SUPPORTS: EACH ICE BRIDGE LEG SHALL BE BONDED TO THE GROUND RING WITH #2 AWG BARE <br /> V`. TINNED COPPER CONDUCTOR. PROVIDE EXOTHERMIC WELDS AT BOTH THE ICE BRIDGE LEG AND BURIED DISH WIRELESS, L.L.C. <br /> - GROUND RING. <br /> PROJECT INFORMATION <br /> ODURING ALL DC POWER SYSTEM CHANGES INCLUDING DC SYSTEM CHANGE OUTS, RECTIFIER REPLACEMENTS <br /> OR ADDITIONS, BREAKER DISTRIBUTION CHANGES, BATTERY ADDITIONS, BATTERY REPLACEMENTS AND SESEA00361 C <br /> INSTALLATIONS OR CHANGES TO DC CONVERTER SYSTEMS IT SHALL BE REQUIRED THAT SERVICE <br /> CONTRACTORS VERIFY ALL DC POWER SYSTEMS ARE EQUIPPED WITH A MASTER DC SYSTEM RETURN GROUND 9610 19TH AVENUE SE <br /> CONDUCTOR FROM THE DC POWER SYSTEM COMMON RETURN BUS DIRECTLY CONNECTED TO THE CELL SITE EVERETT, WA 98208 <br /> REFERENCE GROUND BAR <br /> OTOWER TOP COLLECTOR BUSS BAR IS TO BE MECHANICALLY BONDED TO PROPOSED ANTENNA MOUNT COLLAR. SHEET TITLE <br /> PROPOSED BUSS BAR REFER TO DISH WIRELESS, LLC. GROUNDING NOTES. GROUNDING PLANS <br /> AND NOTES <br /> INSULATORS (TYP) <br /> SHEET NUMBER <br /> G-1 <br /> TYPICAL ANTENNA GROUNDING PLAN NO SCALE 2 GROUNDING KEY NOTES NO SCALE 3 <br />