Laserfiche WebLink
NOTE NOTE <br /> EQUIPMENT CABINET OMITTED FOR CLARITY CABLE GROUNDING NOT REQUIRED WHEN • <br /> ANTENNA IS LESS THAN 10' FROM CABINET <br /> ....sh <br /> PROPOSED GPS UNIT PROPOSED GPS UNIT <br /> wireless- <br /> PROPOSED POST <br /> #2 AWG GROUND <br /> CONDUCTOR TO GRIR'A <br /> 5701 SOUTH SANTA FE DRIVE <br /> LITTLETON, CO 80120 <br /> PROPOSED GPS UN <br /> MOUNT OR APPROVPROPOSED PIPE CLAMPS <br /> RESERVED SPACE FIBER KID, EQUIVALENT <br /> ° _ IF REQUIRED <br /> CO <br /> 11i B PROPOSED 200AMP <br /> METER SOCKET <br /> PROPOSED DISH <br /> • <br /> i WIRELESS, L.L.C. I <br /> POWER PROTECTIVE 11 <br /> CABINET <br /> 1, II 1/2" COAX CABLE PROPOSED PIPE COLUMN MINIMUM BENDING ��PER CABLE MANUFTOWER ENGI EE N PROFESSIONALS <br /> 326 TRY ALEIGH, NCSPECIFICATIONSJx' <br /> TO GROUND 27603 CE: 9 ) 661-6351 <br /> j p TYPICAL GPS UNIT GROUNDING No SCALE <br /> (/� <br /> p L <br /> LL <br /> 1 I n l,S <br /> --------- - P' M A1V <br /> PROPOSED TELCO FIBER .S <br /> �I III PROPOSED F H C <br /> I DISH WIRELESS, I ENCLOSURE (BEHIND) <br /> ( L.L.C. SAFETY J' <br /> I <br /> SWITCH. <br /> I� INSTALL IF II c <br /> PROPOSED EQUIPMENT PAD ii Illi REQUIRED BY III <br /> LL Il i LOCAL UTILITY <br /> F <br /> COMPANY ` I1,x <br /> PROPOSED #2 AWG TIE INTO II `LI________�-�I� 1 ^y <br /> GROUND RING (TYP) �� r----- j cJ025� <br /> ��fi <br /> �h <br /> #2 TINNED SOLID IN 1/2" MIN. LIQUID _ -■QQ o O O o ______ , v <br /> TIGHT CONDUIT FROM 24" BELOW GRADE 00■O O 0■00' — NAL <br /> TO WITHIN 3" TO 6" OF CAD-WELD ■o o O O O■ <br /> TERMINATION PONT.IEXPOSED END OF <br /> a{¢rcb 8,2022 <br /> THE LIQUID TIGHT CONDUIT MUST BE / I \ <br /> SEALED WITH SILICONE CAULK. (TY <br /> 1 IT IS A VIOLATION OF LAW FOR ANY PERSON, <br /> \�7 UNLESS THEY ARE ACTING UNDER THE <br /> --- DIRECTION OF A LICENSED PROFESSIONAL <br /> PROPOSED BOND EQUIPMENT a PROPOSED GROUND RING <br /> GROUND BUS BAR <br /> GROUND BAR TO \ ENGINEER,TO ALTER THIS DOCUMENT. <br /> �I 1 i <br /> ELECTRODE \ DRAWN BY: CHECKED BY: <br /> a <br /> APPR <br /> GROUNDING a OVED BY: <br /> S j SYSTEM (TYP) <br /> a I% CDK CP CP <br /> BASE CONNECTION � REDS REV #: TBD <br /> SERVICE ENTRANCE PROPOSED <br /> GROUNDINGGROUND RING <br /> ELECTRODE # 2 GROUND CONSTRUCTION <br /> CONDUCTOR (GEC)-7DOCUMENTS <br /> NO SCALE OUTDOOR CABINET GROUNDING NO SCALE 3 SUBMITTALS <br /> REV DATE DESCRIPTION <br /> 12" DIA x 24" DEEP ,1 08-05-21 PRELIMINARY <br /> 2 TED SOLID 2" D x INSPECTION SLEEVE PVC OR SOIL PIPE WITH CAP <br /> # INNIN 1/ MIN. LIQUID x B 12-21-21 PRELIMINARY <br /> ¢ <br /> TIGHT CONDUIT FROM 24" BELOW GRADE PIPE x< OR EQUIVALENT C 01-18-22 PRELIMINARY <br /> TO WITHIN 3" TO 6" OF CAD-WELD 1'-0" <br /> TERMINATION POINT. EXPOSED END OF z I N o 03-oa-zz CONSTRUCTION <br /> LIQUID TIGHT CONDUIT MUST BE i FINISHED GRADE <br /> SEALED WITH SILICONE CAULK. / INCLUDE WARNING TAPE WITH <br /> BACKFILL PER SPECIFICATIONS <br /> GRADE <br /> xx����� <br /> /AA/AA/AA/ A&E PROJECT NUMBER <br /> //�//x//�//�% w 147003 <br /> o 0A� ���� �jX��jX���j���j� EXOTHERMIC CONNECTION w <br /> oV�VA�VA�� A�VA�V� m? DISH WIRELESS, L.L.C. <br /> 3/4" CRUSHED STONE OR - PROJECT INFORMATION <br /> wrH2 <br /> �N �oFEroP of TO o&� <br /> GROUNDING LOOP CONDUCTOR o SESEA00361 C <br /> 1 r> GROUND RING, #2 AWG <br /> SOLID <br /> CADWEL (TYP) I GROUND RING \\/ / 3 OPARE TINNED 9610 19TH AVENUE SE <br /> EVERETT, WA 98208 <br /> 2 AWG SOLIDSHEET TITLE <br /> TIE INTO EXISTING COPPER CONDUCTONRD GROUNDING DETAILS <br /> GROUND RING a EXTERIOR GROUND RING <br /> GROUND ROD, 1/2" MIN. x 8'-0" <br /> LONG COPPER CLAD STEEL <br /> (ERICO #625880) SHEET NUMBER <br /> G-2 <br /> TRANSITIONING GROUND DETAIL NO SCALE 4 TYPICAL TEST GROUND ROD WITH INSPECTION SLEEVE NO SCALE 5 TYPICAL GROUND RING TRENCH NO SCALE 6 <br />