My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
3003 W CASINO RD BLDG 45-703 2023-08-01
>
Address Records
>
W CASINO RD
>
3003
>
BLDG 45-703
>
3003 W CASINO RD BLDG 45-703 2023-08-01
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/1/2023 1:32:16 PM
Creation date
7/27/2023 8:44:39 AM
Metadata
Fields
Template:
Address Document
Street Name
W CASINO RD
Street Number
3003
Tenant Name
BLDG 45-703
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
64
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LEGEND: <br /> A B C D E F G H <br /> SO IONIZATION SMOKE DETECTOR <br /> HEAT DETECTOR FIXED 135° <br /> ❑E MANUAL PULL STATION, DOUBLE ACTING <br /> I <br /> ®Q AUDIBLE/VISUAL ALARM <br /> B FIRE ALARM PANEL <br /> 45-703 1 1 <br /> OPEN OFFICE EAc CELLULAR DIALER <br /> NAC NOTIFICATION APPLIANCE CIRCUIT PANEL <br /> 11E2 <br /> - -1 - - - �- - 1/2,C - - - 1/2,C - - - 1/2,C - - - <br /> 2#16 SLC 2#16 SLC 2#16 SLC <br /> 2#14 NAC 45-703 SMK OFFICE W 2#14 NAC 45-703 SMK OFFICE E 2#14 NAC <br /> 30CD ZONE #: 02, L1:02 ZONE #: 01, L1:01 1 GENERAL NOTES <br /> -�--- -----�T-------T $ -�- 1 1 45-713, 45-733 AND 7-773 ARE MONITORED BY <br /> �� 1� 45-703 BUILDING FACP. <br /> ' z�, EVT—FA-45-703 <br /> 3/4"C I /2"c 2#1s/SLIC 3 cD>cD> BUILDING FACP <br /> 2#16 SLC d�2#16 SLC I 1 1 <br /> �2i14 NAC-4 I— — — — � r �P-75CD <br /> 7-773 MAN PULL DR 11A3REFERENCE DRWAWINGS <br /> ZONE #: 07, L1:07 F FILI <br /> Ij <br /> 45-703-E506 FIRE ALARM DETAILS <br /> B�- 15CD F J :J[-__41-1711 MAN ULL DR 11 2A 45-703 MAN PULL DR 11E2B <br /> 7_773 ZONE #: 04, L1:04 ZONE #: 03, L1:03 <br /> WOM NS R "c <br /> 2#16 SLC <br /> 2#14 NAC CONSTRUCTION NOTES <br /> 7-773 HEAT WOMENS R.R. <br /> ZONE #: 05, L1:05 /2"C THIS FIRE ALARM DESIGN IS INTENDED TO BE A <br /> 4 2#16 SLC 30CD ----- --- 30CD PRELIMINARY DESIGN TO DIRECT A NICET CERTIFIED <br /> 2#14 NAC DESIGNER TO COMPLETE FINAL FIRE ALARM DESIGN IN <br /> 3/4"C ACCORDANCE WITH ALL APPLICABLE LAWS AND CODES. <br /> 7-773 HEAT MENS R.R. 4 4 2#16 SLC APPLICATION FOR FIRE ALARM PERMIT USING FINAL <br /> ZONE #: 06, L1:06 1 C 2#1 I #14 NAC STAMPED DRAWINGS IS REQUIRED. <br /> 4 F 1/2"C I 1/2"C I 1/2"C PROVIDE NEW DIGITAL ADDRESSABLE FIRE ALARM CONTROL <br /> 7-773 MAN PULL DR 11A4 # <br /> - - - 2#16 SLC - - 2 16 SLC- - 45-71 2#16 SLC - - PANEL AND WIRE TO DEVICES SHOWN. <br /> 7-773 #14 NA 3 MAN PULL DR <br /> ZONE #: 08, L1:08uA4 2#14 NAC 11F6A 2#14 NAC PROVIDE CELLULAR COMMUNICATOR AND WIRE TO BUILDING <br /> 5G F ZONE #: 15, -1:15 FACP. SEE SHEET E506 FOR INSTALLATION DETAILS. <br /> PROVIDE NOTIFICATION APPLIANCE CIRCUIT, NAC, PANEL AS <br /> I 3/4"C 4 4 1 4 1 REQUIRED TO POWER AND SYNC NOTIFICATION DEVICES. <br /> 2#16 SLC E-_ _ <br /> 3 2#14 NAC $ $I ®PROVIDE NEW FIRE ALARM DEVICES AND WIRE TO NEW <br /> 45-733 SMK OFFICE N �/2"C 45-713 SMK OFFICE N BUILIDNG FACP. (TYP. 8 SMOKE DETECTORS, 8 MANUAL <br /> ZONE #: 09, L1:09 _2#16 SLC_ i ZONE, L1:13 PULL STATIONS, AND 8 HORN/STROBES). ROUTE ALL <br /> 45-733 MAN PULL DR 1106A - % CONDUIT/WIRE UNDERNEATH BUILDINGS AND WALKWAYS. <br /> ZONE #: 11, L1:11 I 5. FILL OUT AND RETURN ATTACHED BUILDING FACP <br /> 1/2"C I POINTLIST TO ENGINEER A MINIMUM OF 3 WEEKS PRIOR <br /> 2#16 SLC 1/2"C <br /> 45-733 2#16 SLC 45-713 TO FINAL ACCEPTANCE TESTING. <br /> 2#14 NAC OPEN OFFICE 2#14 NAC T OPE OFFICE <br /> 1106FlllF6 <br /> O - - - - - - - -l �-1/2 <br /> 2#16 SLC <br /> 2#14 NAC I <br /> 45-733 MAN PULL DR 1106B I 1/2 C 45-713 SMK OFFICE S <br /> ZONE #: 12, L1:12 2#16 SLC a <br /> 4 / 4 ZONE #: 14, L1:14 <br /> I I $ I -$1- - $ I <br /> � - - - - - F - - 70NE3#: 10,3 SMK L1:10CES - - FLAN <br /> - - � <br /> 4 45-71PULL DR I I <br /> 1/2"C ZONE #: 16, L1:16 1/2"C <br /> 1/2"C �2#16 SLC �-2#14 NAC <br /> 2#16 SLC 2#14 NAC <br /> 1 2#14 NAC 1 <br /> 75CD 4 <br /> - ----I - - <br /> — 75CD — — <br /> FLOOR PLAN <br /> SCALE: 3/16" = 1'-O" N 8' 4' 0 4' 8' 16' <br /> SCALE: 1/8"=1 1 <br /> SYM REVISION BY APPROVED DATE SYM REVISION BY APPROVED DATE ACCEPTABILITY DRAWN DATE SUBTITLE CURRENT REVISION SYMBOL GATE <br /> NEW STALL 113 TRAILERS C243685 MDK ABR 01.27.23 THIS DESIGN AND/OR CHECKED FIRE ALARM PLAN C243685 A 04.28.23 0 <br /> SPECIFICATION IS APPROVED SHEET <br /> A SHOP DRAWINGS AGOW/JS 04.28.23BOE//VG® m APPROVED BY DEPT. DATE�# TITLE 1 E260 \ <br /> CHECKED <br /> APPROVED BUILDINGS 45-703,713,733,773 DB NG DMP NO. <br /> APPROVED ELECTRICAL MASTER EVERETT, WA DWG NO. 45-703-1E260 <br />
The URL can be used to link to this page
Your browser does not support the video tag.