Laserfiche WebLink
SPECIFICATIONS <br />System Capacity <br />• Intelligent Signaling Line Circuits................................................I <br />• Addressable device capacity..................................................198 <br />• Programmable software zones.................................................99 <br />• Annunciators.............................................................................16 <br />Electrical Specifications <br />AC Power: Operates in either 120 or 240 VAC, 50/60 Hz, 3.25 A, <br />auto -sensing- no switch required. Wire size: minimum 14 AWG <br />(2.00 mrl with 600 V insulation. Nonpower-limited, supervised. <br />Battery: Two 12 V 18 AH lead -acid batteries. Battery Charger <br />Capacity: 7-18 AH (FireWarden-100X cabinet holds maximum of <br />two 18 AH batteries.) <br />Communication Loop: Supervised and power -limited. <br />Notification Appliance Circuits: Terminal Block provides connec- <br />tions for four NACs, Style Y (Class B) or Style Z (Class A). Special <br />Application power. Power -limited, supervised circuitry. Maximum <br />signaling current per circuit: 2.5 amps special application, 250mA <br />regulated. End -of -Line Resistor: 4.7k ohm, '/2 watt (P/N 71252 UL <br />listed) for Style Y (Class B) NAC; system capable of 1.9 kQ - 22 kQ <br />ELR range. Refer to the NOTIFIER Device Compatibility Document <br />for listed compatible devices. <br />Two Programmable Relays and One Fixed Trouble Relay: Con- <br />tact rating: 2.0 A @ 30 VDC (resistive), 0.5 A @ 30 VAC (resistive). <br />Form-C relays, non -power -limited, non -supervised. <br />Cabinet Specifications <br />Door: 19.26" (48.92 cm.) high x 16.82" (42.73 cm.) wide x 0.72" <br />(1.82 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" (42.29 <br />cm.) wide x 5.25" (13.34 cm.) deep. Trim Ring (TR-CE/B): 22.00" <br />(55.88 cm.) high x 19.65" (49.91 cm.) wide. <br />Shipping Specifications <br />Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high <br />x 22.5" (57.15 cm.) wide x 8.5" (21.59 cm.) deep. <br />Temperature and Humidity Ranges <br />This system meets NFPA requirements for operation at 0 — 49°C/32 <br />— 120°F and at a relative humidity 93% ± 2% RH (noncondensing) at <br />32°C ± 2°C (90°F ± 3°F). However, the useful life of the system's <br />standby batteries and the electronic components may be adversely <br />affected by extreme temperature ranges and humidity. Therefore, it <br />is recommended that this system and its peripherals be installed in <br />an environment with a normal room temperature of 15 — 27°C/60 — <br />80°F. <br />Addressable Device Accessories <br />End -of -Line Resistor Assembly (R-47K and R-3.91K): The <br />47k ohm assembly supervises the NMM-100-10, NDM-100, NMM- <br />100P, and NC-100 module circuits. The 3.9k ohm assembly super- <br />vises the NZM-100-6 module circuit. These resistors are included <br />with each module. <br />Power Supervision Relay: Supervises the power to 4-wire smoke <br />detectors and notification appliances. <br />Wiring Requirements <br />While shielded wire is not required, it is recommended that all SLC <br />wiring be twisted -pair to minimize the effects of electrical interfer- <br />ence. Refer to the panel manual for wiring details. <br />NFPA Standards <br />The FireWarden-100X complies with the following NFPA 72 Fire <br />Alarm Systems requirements: <br />— LOCAL (Automatic, Manual, Waterflow and Sprinkler Supervi- <br />sory). <br />—AUXILIARY (Automatic, Manual and Waterflow) (requires <br />4XTM). <br />—REMOTE STATION (Automatic, Manual and Waterflow) <br />(Where a DACT is not accepted, the alarm, trouble and supervi- <br />sory relays may be connected to UL 864 listed transmitters. For <br />reverse polarity signaling of alarm and trouble, 4XTM is <br />required.) <br />— PROPRIETARY (Automatic, Manual and Waterflow). <br />— CENTRAL STATION (Automatic, Manual and Waterflow, and <br />Sprinkler Supervised). <br />— OT, PSDN (Other Technologies, Packet -switched Data Net- <br />work) <br />— IBC 2012, IBC 2009, IBC 2006, IBC 2003, IBC 2000 (Seismic). <br />— CBC 2007 (Seismic) <br />Agency Listings and Approvals <br />The listings and approvals below apply to the basic FireWarden- <br />100X control panel. In some cases, certain modules may not be <br />listed by certain approval agencies, or listing may be in process. <br />Consult factory for latest listing status. <br />• UL: S635 <br />• CSFM: 7165-0028:0505 <br />• FDNY: COA #6268 <br />I® <br />ENGINEERING B MANUFACTURING <br />QUALITY SYSTEMS <br />This document is not intended to be used for installation purposes. <br />We try to keep our product information up-to-date and accurate. <br />We cannot cover all specific applications or anticipate all requirements. <br />All specifications are subject to change without notice. <br />NOTIFIER <br />AlarmNet@, NOTIFIER@, FireWarden@, SWIFT@, and System Sensor@ <br />are registered trademarks of Honeywell International Inc. Microsoft and <br />12 Clintonville Road <br />Windows@ are registered trademarks of the Microsoft Corporation. <br />CT 06472 <br />©2018 by Honeywell International Inc. All rights reserved. Unauthorized NOTIFIER <br />0Northford, <br />203.484.7161 <br />use of this document is strictly prohibited. <br />by Honeywell <br />www.notifier.com <br />Country of Origin: USA <br />