DN-6724: B3 <br />FCM.1(A) & FRMA (A) <br />Series <br />Control and Relay Modules <br />General <br />FCM-1(A) Control Module: The FCM-1(A) Addressable Con- <br />trol Module provides Notifier intelligent fire alarm control pan- <br />els a circuit for Notification Appliances (horns, strobes, <br />speakers, etc.). Addressability allows the FCM-1(A) to be acti- <br />vated, either manually or through panel programming, on a <br />select (zone or area of coverage) basis. <br />FRM-1(A) Relay Module: The FRM-1(A) Addressable Relay <br />Module provides the system with a dry -contact output for acti- <br />vating a variety of auxiliary devices, such as fans, dampers, <br />control equipment, etc. Addressability allows the dry contact to <br />be activated, either manually or through panel programming, <br />on a select basis. <br />FlashScan® (U.S. Patent 5,539,389) is a communication pro- <br />tocol developed by NOTIFIER Engineering that greatly <br />enhances the speed of communication between analog intelli- <br />gent devices. Intelligent devices communicate in a grouped <br />fashion. If one of the devices within the group has new infor- <br />mation, the panel CPU stops the group poll and concentrates <br />on single points. The net effect is response speed greater than <br />five times that of other designs. <br />Features <br />• Built-in type identification automatically identifies these <br />devices to the control panel. <br />• Internal circuitry and relay powered directly by two -wire <br />SLC loop. The FCM-1(A) module requires power (for horns, <br />strobes, etc.), or audio (for speakers). <br />• Integral LED "blinks" green each time a communication is <br />received from the control panel and turns on in steady red <br />when activated. <br />• LED blink may be deselected globally (affects all devices). <br />• High noise immunity (EMF/RFI). <br />• The FCM-1(A) may be used to switch 24-volt NAC power, <br />audio (up to 70.7 Vrms). <br />• Wide viewing angle of LED. <br />• SEMS screws with clamping plates for wiring ease. <br />• Direct -dial entry of address 01— 159 for FlashScan loops, <br />01 — 99 for CLIP mode loops. <br />• Speaker, and audible/visual applications may be wired for <br />Class B or A (Style Y or Z). <br />Applications <br />The FCM-1(A) is used to switch 24 VDC audible/visual power, <br />high-level audio (speakers). The FRM-1(A) may be pro- <br />grammed to operate dry contacts for applications such as door <br />holders or Air Handling Unit shutdown, and to reset four -wire <br />smoke detector power. <br />NOTE: Refer to the SLC Manual (PN 51253) for details regarding <br />releasing applications with the FCM-1(A). Refer to the FCM-I-REL <br />datasheet (DN-60390) for new FlashScanO releasing applications. <br />Construction <br />• The face plate is made of off-white heat -resistant plastic. <br />• Controls include two rotary switches for direct -dial entry of <br />address (01-159). <br />�J NOTIFIER° <br />by Honeywell <br />O <br />T11 Ea1PWR1-) <br />� <br />I O ourMexi ,n <br />T10E.t PWRJ-) TI <br />FCM-1(A) <br />• The FCM-1(A) is configured for a single Class B (Style Y) or <br />Class A (Style Z) Notification Appliance Circuit. <br />• The FRM-1(A) provides two Form-C dry contacts that <br />switch together. <br />Operation <br />Each FCM-1(A) or FRM-1(A) uses one of 159 possible module <br />addresses on a SLC loop (99 on CLIP loops). It responds to <br />regular polls from the control panel and reports its type and <br />status, including the open/normal/short status of its Notifica- <br />tion Appliance Circuit (NAC). The LED blinks with each poll <br />received. On command, it activates its internal relay. The <br />FCM-1(A) supervises Class B (Style Y) or Class A (Style Z) <br />notification or control circuits. <br />Upon code command from the panel, the FCM-1(A) will dis- <br />connect the supervision and connect the external power sup- <br />ply in the proper polarity across the load device. The <br />disconnection of the supervision provides a positive indication <br />to the panel that the control relay actually turned ON. The <br />external power supply is always relay isolated from the com- <br />munication loop so that a trouble condition on the external <br />power supply will never interfere with the rest of the system. <br />Rotary switches set a unique address for each module. The <br />address may be set before or after mounting. The built-in <br />TYPE CODE (not settable) will identify the module to the con- <br />trol panel, so as to differentiate between a module and a sen- <br />sor address. <br />Specifications for FCM-1(A) <br />Normal operating voltage: 15 to 32 VDC. <br />Maximum current draw: 6.5 mA (LED on). <br />Average operating current: 350 pA direct poll, 375 pA group <br />poll with LED flashing, 485 pA Max. (LED flashing, NAC <br />shorted.) <br />DN-6724:B3.2/17/2011 — Page 1 of 2 <br />