6/16/2022 Pa I <br />City of Everett Page 4 <br />7:13 '16AM <br />INSPECTION ACTIVITY REPORT <br />4/29/2022 4/29/2022 PLUMB JJM <br />CORRECTION eTRAKiT Inspection <br />4/28/2022 12:01 PM Melissa Mylius <br />03-ROUGH IN <br />Request <br />Contact Name: Melissa Mylius <br />Site Address: 2916 LEONARD DR <br />Phone:4252444747 <br />e-Mail: mcml3@rocketmail.com <br />(4/29/2022 1:09 PM JJM) <br />- ABS DWV has still not been put on test <br />through roof as asked for in previous <br />inspection per code. Waste has to be onsite <br />visually confirmed by an inspector per UPC <br />712.2 Water Test: <br />The water test shall be applied to the <br />drainage and vent systems either in its <br />entirety or in sections. Where the test is <br />applied to the entire system, openings in the <br />piping shall be tightly closed, except the <br />highest opening, and the system filled with <br />water to the point of overflow. Where the <br />system is tested in sections, each opening <br />shall be tightly plugged, except the highest <br />opening of the section under test, and each <br />section shall be filled with water, but no <br />section shall be tested with less than a 10 <br />foot head of water (30 kPa). Keep system <br />under test, for not less than 15 min prior to <br />inspection. <br />- Replace 3" San tee on its back with proper <br />drainage fitting per UPC section 706.2 <br />Horizontal to Vertical. <br />- Roll combo for main bath toilet above <br />centerline of drain per UPC 905.2 <br />Horizontal Drainage Pipe: <br />Where vents connect to a horizontal <br />drainage pipe, each vent pipe shall have its <br />invert taken off above the drainage <br />centerline of such pipe downstream of the <br />trap being served. <br />6/14/2022 6/14/2022 PLUMB 08-FINAL JJM <br />NOT READY eTRAKiT Inspection <br />6/9/2022 5:59 PM Melissa Mylius <br />Request <br />Contact Name: Melissa Woodson <br />Site Address: 2916 LEONARD DR <br />Phone:4252444747 <br />e-Mail: mcml3@rocketmail.com <br />6/14/2022 6/14/2022 PLUMB JJM <br />CORRECTION <br />(6/14/2022 11:35 AM JJM) <br />03-ROUGH IN <br />- Repair leak on ABS 3 by 2 combo vent tie <br />in for back bathroom toilet in crawlspace. <br />Ok to reset waste test for isolation of back <br />bathroom only. <br />6/15/2022 6/15/2022 PLUMB 08-FINAL JJM <br />APPRVD-PERK eTRAKiT Inspection <br />6/14/2022 1:12 PM Melissa Mylius <br />Request <br />Contact Name: Melissa Mylius <br />Site Address: 2916 LEONARD DR <br />Phone:4252444747 <br />e-Mail: mcm13@rocketmail.com <br />6/15/2022 6/15/2022 PLUMB JJM <br />APPROVAL <br />03-ROUGH IN <br />INSP 12 ,1 <br />s YJ TF�t s .J <br />