My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1818 HOLBROOK AVE B 2023-07-31
>
Address Records
>
HOLBROOK AVE
>
1818
>
1818 HOLBROOK AVE B 2023-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2023 1:24:16 PM
Creation date
7/31/2023 1:22:57 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLBROOK AVE
Street Number
1818
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
measured in the direction of travel. See exteriorGeneral doorComment for at the storage/utilitinformati ) <br /> y room. Note that the ti <br /> door is currenty as existing (see more on . <br /> • RESPONSE: Landings have been added and noted on plans. <br /> Architectural 13. It appears that the rear deck(directly outside the laundry door) and the <br /> landing for the sliding glass door in the dining room is not shown on the plans. Plans should be <br /> updated to include all existing and new work(see General Comment for more information). <br /> • RESPONSE: Deck and landing have been added and noted on architectural <br /> plans A.03. Rear deck structural also included in structural plans and response. <br /> Architectural 14. The architectural drawings should include a schedule listing the selected <br /> energy credits for the proposed project. The building should be designed to comply with the <br /> additional energy efficiency requirements, see WSEC Section R406. <br /> • RESPONSE: The energy schedule has been added to the architectural drawings <br /> page A.03 and worksheets have been included as well. <br /> Architectural 15. See Second Floor Plan, Proposed on Sheet A.03. It appears that the <br /> existing deck guard was replaced without the required permits (see General Comment). Plans <br /> should specify the existing guards to be replaced with glazed guards. Glazing in guards should <br /> be specified as safety glazing. Additional requirements for glazing in guards can be found in <br /> Section R308.4.4. A detail should be provided showing the connection to the deck, required <br /> height, and spacing of the posts. See Section 312.1 for guard requirements. Note that even <br /> though the guard is existing in place and look to be installed according to code, it should be <br /> treated as new construction and a detail showing all requirements is still required. <br /> • RESPONSE: The details for the deck guards has been added to the proposed <br /> plans on page A.04.08. <br /> If there are any further questions or required clarification, please contact me directly. <br /> Thank you, <br /> Charlie Apel <br /> Gathered House, LLC <br /> 425-591-7154 <br /> charlie@gatheredhouse.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.