My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1818 HOLBROOK AVE B 2023-07-31
>
Address Records
>
HOLBROOK AVE
>
1818
>
1818 HOLBROOK AVE B 2023-07-31
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/31/2023 1:24:16 PM
Creation date
7/31/2023 1:22:57 PM
Metadata
Fields
Template:
Address Document
Street Name
HOLBROOK AVE
Street Number
1818
Unit
B
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
67
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-/LJ ♦ • 1/ <br /> Architectural 6. Dwelling units should be equipped with local exhaust and whole-house <br /> ventilation systems design and installed as specified in Section M1505. See local exhaust rates <br /> in Section M1505.4.4. R303.4 <br /> • RESPONSE: This has been noted on proposed plans on page A.03. <br /> Architectural 7. Plans should specify ceiling heights of the new rooms on the first floor. <br /> Minimum ceiling height of habitable space and hallways should be not less than 7 feet. R305.1 <br /> • RESPONSE: Ceiling heights for the new rooms on the first floor have been noted <br /> on proposed plans on page A.03. <br /> Architectural 8. See Second Floor Plan, Proposed on Sheet A.03. Safety glazing should be <br /> specified for the window above the bathtub in the bathroom. R308.4.5 <br /> • RESPONSE: Safety glazing for window above tub and other areas has been <br /> specified on proposed plans and elevations. <br /> Architectural 9. See First Floor Plan, Proposed on Sheet A.03. Safety glazing should be <br /> specified for the window adjacent to the door in the storage/utility room. Note that the plans are <br /> currently showing this area as existing but do not appear in the records (see General Comment <br /> for more information). R308.4.2 <br /> • RESPONSE: See General 1 and Architectural 1 responses. Safety glazing has <br /> been specified on proposed plans and elevations. <br /> Architectural 10. See First Floor Plan, Proposed on Sheet A.03. A section should be provided <br /> showing the construction requirements and difference in elevations at the location of the steps <br /> that lead from the kitchen to the dining room. It is not clear if the stairs are concrete or timber <br /> framing. <br /> • RESPONSE: Details of the steps have been added and noted on structural plans <br /> SD-2/16. <br /> Architectural 11. Continuing with the previous comment, it is not clear if the steps are <br /> concrete or timber framing. A detail should be provided showing the requirements for the stair <br /> tread and risers. Detail should show top and bottom connections and provide protection against <br /> decay for wood framing in contact with concrete per Section R317. <br /> • RESPONSE: Details of the steps have been added and noted on structural plans <br /> SD-2/16. <br /> Architectural 12. Plans should show landings at exterior doors per Section R311.3. Landing <br /> width should be not less than the door served and have a dimension of not less than 36 inches <br />
The URL can be used to link to this page
Your browser does not support the video tag.