Emergency Foundation Under.g Memorandum • NGA File No. 13333B22 <br /> Miller Residence Landslide January 18,2023 <br /> Everett,Washington Page 2 <br /> approximately 1/8-inch of downslope soil movement within the upper 5-to 6-feet of soil. We visited the <br /> site again on January 11, 2023. We noted additional soil movement along the planter strip adjoining the <br /> southern face of the southeastern portion of the residence.The soils in this area were separating from <br /> the foundation stem wall by approximately 1- to 2-inches. At this time, we also exposed the house <br /> foundation in one location along the southeast corner of the house and observed that the footing was <br /> undermined by approximately 2-inches. <br /> CONCLUSIONS AND RECOMMENDATIONS <br /> We have been monitoring slope stability conditions at the site on a monthly basis since November 2022. <br /> Based on our recent observations, it is our opinion that the slide mass is mobilizing at a significant rate <br /> and that the house foundations along the southeastern house extension are at serious risk of being <br /> adversely impacted by slope movement.This portion of the residence should be temporarily underpinned <br /> on an emergency basis to mitigate adverse impacts to the residence as a result of further ground <br /> movement,while permanent landslide stabilization plans are completed. <br /> For the underpinning,we recommend 2-inch diameter steel piles driven along the southern perimeter of <br /> the southeastern portion of the house and structurally attached to the residence foundation. Each pin <br /> pile should be driven to refusal utilizing a 140-pound pneumatic post driver. Refusal criteria is defined as <br /> 1-inch or less of vertical movement within 60 seconds of continuous driving.The piles should be attached <br /> and vertically restrained to the house foundations utilizing structural brackets. For piles successfully <br /> driven to refusal we recommend a design axial compression capacity of 3 tons per pile.The underpinning <br /> repairs should be performed by an experienced contractor licensed in the state of Washington. <br /> Additionally, we recommend the pile installation and refusal criteria is performed under continuous <br /> supervision of NGA. In support of the emergency underpinning,we have discussed plans with the project <br /> structural engineer who has provided a schematic pile layout of the areas to be stabilized, as shown on <br /> Figure 1. Given the site conditions, it is our opinion the proposed work should be considered for <br /> emergency permitting and carried out as soon as possible. <br /> CLOSURE <br /> We trust this memorandum should satisfy your needs at this time. Please contact us if you have any <br /> questions or require additional services. <br /> o-o-o <br /> r) <br /> NELSON GEOTECHNICAL ASSOCIATES, INC. <br />