My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
1130 75TH ST SE 2023-08-08
>
Address Records
>
75TH ST SE
>
1130
>
1130 75TH ST SE 2023-08-08
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/8/2023 1:41:11 PM
Creation date
7/31/2023 2:52:18 PM
Metadata
Fields
Template:
Address Document
Street Name
75TH ST SE
Street Number
1130
Imported From Microfiche
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• <br /> p GC�I�U�IL� <br /> August 2, 2021 <br /> AUG052021 <br /> CITY OF EVERETT <br /> TO: Drew Martin Permit Services <br /> FROM: Philip Gerou <br /> RE: Comments sent regarding application #BW2012-015 <br /> The drawings still require modifications. In addition to my original email,the following needs to be addressed: <br /> 1. The existing(as-built) plans should clearly indicate the existing walls that will be demolished. <br /> The revised plans show walls to be existing walls to be removed. <br /> 2. The new(proposed) plans should clearly show the new walls. These should be delineated by shading the new <br /> walls(leave exiting walls unshaded), or another industry-standard method. <br /> The proposed plans now show new walls and framing shaded. Framing notes are on Page A-5 <br /> 3. The basement of the house is not permitted as habitable space. The propose project includes providing a bedroom <br /> in the basement. The space needs to be insulated per the 2015 WSEC Chapter 4. Energy information is noted in <br /> the drawings, but the proposed insulation at all required wall and floor elements is not clear. In addition,energy <br /> credits are required per Section R406; a schedule of the selected credits should be stated in the drawings. The <br /> interior walls should comply with the requirements for exterior walls unless the entire basement is <br /> converted. Floor/ceiling and under(or over) slab insulation is also required. <br /> The proposal to turn the basement into habitable space has been withdrawn. It is noted that the areas of the <br /> existing washing machine and dryer and proposed new bathroom do have ceiling heights that exceed 6'8"to <br /> comply with code. <br /> 4. The bedroom is below grade and appears to require a window well. Dimensions and details for both the egress <br /> window and window wall are required. See IRC Section R310. <br /> The window is not below grade and the proposed egress window changed to a standard window. <br /> 5. The exterior walls are being modified, including but not limited to the basement egress window,and windows <br /> along the south and west main floor exterior walls. Details for the walls, including framing and insulation <br /> requirements, are required. <br /> Framing detail, construction notes,window schedule,and insulation schedule are included on page A-5. <br /> 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.