CARRIER: s <br /> • FINISHED GRADE, OR GROUND TRENCH 6" WIDE WARNING TAPE <br /> COVER MATCH SLOPE AND TO RUN THE ENTIRE <br /> THICKNESS OF EXISTING LENGTH OF TRENCH 8" Sprints <br /> TO 10" BELOW GRADE <br /> SPRINT TO EXTEND •_ • _ In <br /> H-FRAME (3'X6') z 1e-IN�II 11�////`��//�/� 1,. .•..• <br /> FV TO INSTALL NEW NID p!p�p'4.\/\/�.�_, COMPACTED BACKFILL <br /> s, FV TO INSTALL FIBER AND POWER //✓;Y>/�i� " 1,. ' <br /> ON NEW H-FRAME 'i "a ..N.\!\\j!\N... /4 WITH SATISFACTORY <br /> FROM RESPECTIVE NEW J-BOXES N M ��- iIT NATIVE OR IMPORTED PLAN PREPARED FOR: <br /> AND GROUNDING TO THE NEW NID �° 5 114 ISM o , SOIL TO 95% PROCTOR 1 <br /> 9 SPRINI 10 INSTALL (2) NEW J-BOXES, " �I �IIINNA COMPACTED CLEAN FILL <br /> —� 12"X12"X8", (1 FOR FIBER, 1 FOR �•'11=11 F+��-� �� .-� 540 W.MADISON ST. <br /> ������1I 11.:i.. COMPACTED IL 606st <br /> EXISTING , , POWER) AND 2" INTERCONNECT CONDUIT NEW 3" SCH 40 PVC CONDUIT (2) I= = CLEAN FILL BED `r J CHICAGO.www.sacwCOT THE NEW (2) J-BOXES BELOW 1" INNER-DUCTS W/TRACER WIRE UNDISTURBED SOIL WIRELESS 312895.4sn <br /> CLEARWIRE NEW NID ON THE EXTENDED H-FRAME <br /> EQUIPMENT (#12 AWG STRANDED W/ ORANGE ANOKIA"COMPANY <br /> CABINET JACKET) FOR FIBER <br /> FROM PROPOSED MMP TO NEW • <br /> ' _� PURCELL7�� BO�X���g r PLAN PREPARED BY: 1 <br /> C I 1TILifY <br /> CONDUIT- :ULC 4PE QUANTITY, AND SEPARATION DIMENSION TO BE L <br /> - E :hh1huEi <br /> JBOX JBOX VERIFIED WITH LOCAL UTIUTY. <br /> SPRINT TO INSTALL (3) 1-1/4" CONDUIT- 1— I 2. ALL UTILITY TRENCHES WITHIN THE FENCED COMPOUND OR UNDER ANY <br /> (NON-METALLIC SEAL TIGHT) FROM THE i PORTION OF A GRAVEL DRIVE AND/OR ROADWAY SHALL BE BACKFILLED LETS America, Inc. <br /> NEW NID TO THE NEW (2) J-BOXES ON I I I L. <br /> WITH AASHTO #57 COMPACTED AGGREGATE. <br /> THE EXTENDED H-FRAME; (2) OF THE 5 3. ALL CONDUITS SHALL BE INSTALLED WITH 3/16" POLYPROPYLENE ROPE 112 S. KYRENE RD. STE. 1 <br /> (PULL STRING) SUITABLE FOR PULLING CABLE THROUGH DUCT. CHANDLER, AZ 85226 <br /> 1-1/4" CONDUITS WILL COME FROM PROPOSED MMP IS LOCATED ON THE 4. ALL CONDUITS THAT ARE TO BE USED FOR FIBER/ALARM SHALL BE ARIZONA: 480-961-9151 <br /> NEW FIBER J-BOX TO NEW NID AND (1) WEST SIDE OF 80TH STREET SW TO THE INSTALLED WITH A TRACER WIRE (#12 AWG STRANDED W/ ORANGE LETS PROJ. I: LETS-255-MW TO LIT FIBER / <br /> 1-1/4" CONDUIT WILL COME FROM THE SOUTH SIDE OF A UTILITY POLE JACKET).. <br /> 5. ALL CONDUITS SHALL BE CLEAN INSIDE WITH NO DIRT OR ANY OTHER • <br /> NEW POWER J-BOX TO THE NEW NID (VZ 275690) (49.92566', -122.243021 OBSTRUCTIONS. REVISIONS <br /> 6. ALL BENDS MUST SWEEP 36" RADIUS AND MAXIMUM OF 3 SWEEPS. ANY <br /> SPRINT TO INSTALL ±14' OF NEW (1) 2" SPRINT TO INSTALL ±278' OF NEW 3" ADDITIONAL SWEEPS MUST BE APPROVED BY THE UTIUTY COMPANY. REV. DATE--DESCRIPTION HMS <br /> CONDUIT FROM NEW FIBER J-BOX TO CONDUIT WITH (2) 1" INNER-DUCTS FROM 7. THE CONTRACTOR SHALL VERIFY AND FOLLOW THE UTIUTY COMPANY A 10 02 18 90% CD'S RMD <br /> EXISTING CLEARWIRE CABINET THE NEW FIBER J-BOX ON EXTENDED SPECIFICATIONS FOR INSTALLATIONS. / / <br /> H FRAME TO THE PROPOSED MMP LOCATION 8. THE CONTRACTOR SHALL LOCATE ALL EXISTING UTIUTIES WITHIN THE <br /> SPRINT TO INSTALL ±14' OF FIBER AND COMPOUND AND INSTALL PULL BOXES WHERE NEEDED TO AVOID ANY B 01/17/19 95% CD'S BPS <br /> POWER THROUGH NEW 1 2" CONDUIT FV TO INSTALL ±278' OF NEW FIBER THROUGH EXISTING UTILITIES. CONTRACTOR MUST EXERCISE EXTREME CAUTION <br /> FROM THE NEW (2))J-BOXES ON NEW 3" CONDUIT WITH (2) 1" INNER-DUCTS REQUIREDENCHING AND HAND DIG AROUND EXISTING UTILITIES AS 0 02/12/19 FOR OON6fRlX'fION CMZ <br /> EXTENDED H-FRAME TO THE EXISTING FROM THE NEW FIBER J-BOX ON EXTENDED NOTE: <br /> CLEARWIRE CABINET „-FRAME TO THE PROPOSED MMP LOCATION <br /> CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES WITHIN THE <br /> COMPOUND AND INSTALL PULLBOXES WHERE NEEDED TO AVOID ANY <br /> EXISTING UTILITIES. CONTRACTOR MUST EXERCISE EXTREME CAUTION WHEN --- <br /> TRENCHING AND HAND DIG AROUND EXISTING UTILITIES AS REQUIRED. <br /> FIBER SCHEMATIC SCALE 5 TRENCH DETAIL N.T.S.4E 4 NOT FOR CONSTRUCTION UNLESS <br /> LABELED AS CONSTRUCTION SET <br /> PIPE CAP <br /> NOTE: ALL CONDUITS INTO NOTE: H-FRAME SHOULD BE 3' WIDE BY NOTE: ALL 4 CONDUITS INTO <br /> 36" 6" SPRINT TO EXTEND BTS ARE VIA MUDROOM 6' TALL TO ACCOMMODATE COMCAST NID NID ARE BOTTOM FED �^' <br /> X H-FRAME (3'X6') ! ••\) •R. "1, <br /> o_ 'Cr'- • FV TO INSTALL NEW I 1 1 %' •..a : "'i <br /> NID ON EXTENDED • O:' <br /> ° H-FRAME NOTE: DO NOT PLACE FIBER CABLES INSIDE N z; <br /> ° NID OF THE J-BOX CONTAINING THE POWER " <br /> JUNCTION BOX. c NEW o ' 1/2" U-BOLT TERMINAL/CONNECTIONS. FIBER WILL BE '0 •. ' <br /> 0 0 (TYP. OF 8) I I PLACED IN FIBER J-BOX ONLY W : 52811 c..4/ <br /> _ _ 2" RIGID CONDUIT O\ •••••%—rEv G�N- <br /> DIMENSION: 12" X 12" X 8" + o 0 <br /> T� y d CARRIER HAND-OFF F S' N <br /> 1-1/a" FLEX S 10NA1-� <br /> SPRINT TO INSTALL (2) NEW �I CLEARWIRE ‘' /12/19 <br /> 1-BOXES,12"X12"X8", (1 FOR \ 'co1000 UNISTRUT o CABINET CONDUIT <br /> FIBER, 1 FOR POWER) <br /> TYP. OF 4 I HEREBY CERTIFY THAT THESE M YA WERE <br /> TOP SIDE ( ) 1 PREPARED BY ME OR UNDER MY DIRECT <br /> - - I SUPERVISION AND THAT I AM A DULY <br /> 3— 3.0 STD (3.5" OD) y_ -TRIMM PANEL/DC POWER REGISTERED ENGINEER UNDER THE LAWS OF <br /> JBOX JBOX GALV. STEEL POST I I JBOX _ JBOX I DISCONNECT/FUSE t THE STATE OF WASHINCTON' <br /> = DRAINFINISHGRADE TO _ GROUND WIRE PLACED t SE52XC336 <br /> 00 �IN 1/2" SEAL TIGHT WA-SNO201F18.1 <br /> AUGURED HOLE GROUND BAR <br /> W/SONOTUBE -z—GROUND RING/ROD 80TH SW AM.TOWER <br /> i <br /> \ N. 709 80TH SW <br /> _•``� j r j. - - • EVERETT,WA 98023 <br /> . •• •. 2" RIGID CONDUIT 3" RIGID CONDUIT-FEED <br /> I / CARRIER PROVIDE r•SHEET TITLE: N <br /> --J � * : • "�; POWER FROM OSP LATERAN MMP <br /> c --- 1 ;' o POWER CLEARWIRE <br /> ��.� -' STUB 3" RIGID CONDUIT J- TO MW-TO-"LIT FIBER <br /> C -I - 1 AT H-FRAME THEN REDUCE TO <br /> PLACE �; [ FIBER 1-1/4" FLEX CONDUIT TO NID <br /> CONCRETE EQUIPMENT DETAILS <br /> V.. MMP <br /> a •' <br /> WIRE BRUSH AND SOLVENT CLEAN 1'-0"1 GROUND 1 <br /> EMBEDDED PORTION OF PIPE AS SHEET NUMBER: <br /> REQUIRED TO REMOVE ALL GREASE, NOTE: PLACE POWER CABLES ONLY INSIDE J-BOX. <br /> LOOSE SCALE AND ALL MATERIAL ALL FIBER FEED GO DIRECTLY TO NID <br /> DELETERIOUS TO CONCRETE BOND <br /> JUNCTION BOX DETAIL SCALE 3 NEW H-FRAME EXTENSION DETAILS SCALE 2 COMCAST CONFIGURATION DIAGRAM <br /> N.T.S.SCALE <br /> N.T.S. N.T.S. 1 <br /> ' <br />