BUILDING INFORMATION SCHEDULE OF PRINTS <br /> BUILDING DESCRIPTION:OFFICE,STORAGE,FACTORY <br /> BUILDING OCCUPANCY:B,S-1,F-1 <br /> SHEET# DESCRIPTION EV 0 REV 1 REV 2 <br /> SPRINKLERED:YES PERFORMANCETIM KUDELA,SET <br /> WIRING CLASS:B FAO.01 BILL OF MATERIALS,MATRIX AND GENERAL INFO NICET FIRE ALARM SYSTEMS <br /> SCOPE OF WORK SYSTEMS INTEGRATION FA1.01 PARTIAL FLOOR PLAN,RISER DIAGRAM,CALCULATION AND DEVICE DETAILS LEVEL IV: 76863 <br /> EXP: 6/1/2023 <br /> THE INFORMATION ON THIS DRAWING IS THE <br /> THIS IS A TENANT IMPROVEMENT PROJECT.A NEW NOTIFICATION DEVICES WILL BE INSTALLED TO PROVIDE PROPER COVERAGE ORIGINAL,UNPUBLISHED WORK OF <br /> FOR THE AREA OF WORK CONSISTING OF: PERFORMANCE SYSTEMS INTEGRATION LLC. <br /> • HORN/STROBES FIRE ALARM I SECURITY I CCTV I COMMUNICATIONS <br /> DISCLOSURE,REPRODUCTION,OR USE <br /> WITHOUT THE PRIOR WRITTEN CONSENT OF <br /> • STROBES 301 PORTER WAY, MILTON,WASHINGTON 98354 PERFORMANCE SYSTEMS INTEGRATION LLC IS <br /> PROHIBITED. <br /> COM-PHONE(503)641-2222-FAX(503)641-1464-LICENSE OR-CLE569 <br /> THE NEW NOTIFICATION DEVICES WILL BE CONNECTED TO THE EXISTING FIRE ALARM CONTROL PANEL VIA NEW NAC CIRCUIT. INFO@PSINTEGRATED. O <br /> FIRE ALARM BILL OF MATERIALS <br /> ro <br /> 0 <br /> O <br /> w <br /> a <br /> 526 COMMERCE CENTER <br /> QTY QTY SYMBOL DESCRIPTION MODEL# MFG. w <br /> (NEW) EXISTING z <br /> U <br /> 1410 80TH STREET SW 1 EXISTING FIRE ALARM CONTROL PANEL 5208 SILENT KNIGHT z J <br /> FACP N <br /> 7 --- 2 12V SEALED LEAD ACID BATTERY EXISTING EXISTING U <br /> 2 -- HORN/STROBE-WALL MOUNT P2RL SYSTEM SENSOR 5 N <br /> APPLICABLE BUILDING CODES EVE RETT, WA 98203 2 -- STROBE-WALL MOUNT SGRL SYSTEM SENSOR FA1.01 00 <br /> 2018 INTERNATIONAL BUILDING CODE <br /> 2018 INTERNATIONAL FIRE CODE L <br /> U <br /> 2016 NFPA 72 <br /> 2020 NFPA 70 N <br /> EXISTING FUNCTIONAL MATRIX <br /> CENTRAL STATION MONITORING o <br /> TRANSMISSION TYPE:(PHONE LINE,CELL,RADIO) a W <br /> COMMUNICATION TYPE:(4+2,CID) Q <br /> MONITORING COMPANY: w q <br /> ACCOUNT NUMBER: w <br /> PHONE NUMBER: LL <br /> w <br /> FIRE ALARM SUBMITTAL REQUIREMENTS SYSTEM OUTPUTS z <br /> FIRE ALARM NOTIFICATION FIRE SAFETY a v <br /> CONTROL UNIT CONTROL <br /> 1. THE WORK SITE ADDRESS AND WORK ACTIVITY LOCATION W Z O <br /> 2. WORK SITE OWNER OR TENANT CONTACT NAME,ADDRESS,AND TELEPHONE NUMBER �p O z <br /> 3. CONTRACTOR OR INSTALLER INFORMATION,INCLUDING STATE ELECTRICAL LICENSE NUMBER= 2U Z U <br /> 4. DESCRIPTION OF WORK 2 <br /> 5. THREE SETS OF SCALED PLANS,NOT SMALLER THAN 11 X 17 INCHES.YOUR PLANS MUST INCLUDE: O= z <br /> 5.1. FLOOR PLAN INDICATING THE USE OF ALL ROOMS U �� = U w <br /> 5.2. RISER DIAGRAM UQ v y h 20�Q a� LU = W M <br /> 5.3. LOCATION OF ALL ALARM-INITIATING DEVICES O�O�O =�\ 20 y _ a p <br /> 5.4. LOCATION OF ALL ALARM NOTIFICATION DEVICES,INCLUDING CANDELA RATINGS FOR VISIBLE DEVICES U�U� J= j��y0�0� Q zz LU <br /> LU o0 <br /> 5.5. LOCATION OF ALARM CONTROL,TRANSPONDERS,AND NOTIFICATION POWER SUPPLIES U 2�_�= U� ��J4 Q U Cr. — p L IX 0) <br /> 5.6. ANNUNCIATION =y Q�v ,S j 2tu�J2U J 0 1-- >Q <br /> 5.7. POWER CONNECTION > -Z = O�p� J 2 20 O C/) w <br /> 5.8. BATTERY CALCULATIONS =�O�U) v� O = �O Q O v� LLE C < U = <br /> 5.9. VOLTAGE DROP CALCULATIONS m"�O� U�e =ems a =� LL CD ~ <br /> 5.10. WIRING TYPES AND SIZES F //'1 Oo W <br /> W N 0 N w <br /> 5.11. MANUFACTURER'S DATA SHEETS WITH MODEL NUMBERS AND INFORMATION FOR EQUIPMENT,DEVICES,AND MATERIALS Q ��r O O O "�Jy y <br /> 5.12. CEILING HEIGHT AND CONSTRUCTION DETAILS O=O=O=O= l(= S�m��Q O� } o ^ -'t > <br /> 5.13. INTERFACE OF FIRE SAFETY CONTROL FUNCTIONS g m�� to J q �� 0 C/ M LO W <br /> NOTES TO INSTALLING CONTRACTOR <br /> raa <br /> 1. ALL DEVICES PROVIDED AS PART OF THIS PROJECT SHALL BE INSTALLED PRIOR TO CONTACTING PERFORMANCE SYSTEMS NO ENTRY=N/A Q Q Q Q Q <br /> INTEGRATION,LLC(PSI)FOR SCHEDULING A PROGRAMMING TECHNICIAN. SYSTEM INPUTS A B C D E F G H I J K L M N O P Q W o <br /> 2. WIRING MUST BE COMPLETE,DRY,AND FREE OF SHORTS AND GROUNDS WITH NO EXCEPTIONS PRIOR TO CONTACTING PSI 1 MANUAL FIRE ALARM PULL STATION • • • • • 1 ~ `! <br /> FOR SCHEDULING A PROGRAMMING TECHNICIAN. Q <br /> m <br /> 2 SMOKE DETECTOR • • • • • 2 <br /> 3. WHEN CONDUIT IS REQUIRED,CONDUIT SIZE SHALL CONFORM TO CONDUIT FILL CAPACITIES AS PER THE REQUIREMENTS OF 3 HEAT DETECTOR • • • • • 3 <br /> THE NATIONAL ELECTRICAL CODE(NEPA 70)AND THE LOCAL JURISDICTION. 4 DUCT SMOKE DETECTOR • • • 4 <br /> 4. UNDERGROUND AND EXTERIOR CONDUITS SHALL HAVE WATER-TIGHT FITTINGS AND WIRE SHALL BE APPROVED FOR WET 5 SPRINKLER WATER FLOW SWITCH • • • • • 5 <br /> LOCATIONS AS PER THE REQUIREMENTS OF NFPA 70 AND THE LOCAL JURISDICTION. 6 SPRINKLER CONTROL VALVE TAMPER SWITCH • • • 6 <br /> 5. ALL FIRE ALARM DEVICES AND JUNCTION BOXES EXPOSED TO THE WEATHER OR INSTALLED IN BELOW GRADE AREAS SHALL 7 FIRE ALARM AC POWER FAILURE • • • 1 1 17 <br /> BE LISTED FOR USE IN A WET ENVIRONMENT.ALL DEVICES SHALL BE INSTALLED PER THE MANUFACTURER'S RECOGNIZED 8 FIRE ALARM SYSTEM LOW BATTERY • • • 8Z <br /> WEATHER-/WATER-TIGHT INSTRUCTIONS.NO EXCEPTIONS. 9 FIRE ALARM SYSTEM OPEN CIRCUIT • • • 9 O w <br /> 6. PROGRAMMING OF THE FIRE ALARM SYSTEM AND ASSOCIATED POINT DESCRIPTIONS WILL BE BASED ON THESE DESIGN 10 FIRE ALARM SYSTEM SHORT CIRCUIT • • • 10 a to <br /> 11 •• • 11 ~ <br /> DRAWINGS.PSI MUST BE NOTIFIED OF ANY CHANGES TO ROOM USE OR DESIGNATIONS IN WRITING.ANY CORRECTIONS FIRE ALARM SYSTEM GROUND FAULT � I <br /> RESULTING FROM CHANGES NOT SUBMITTED TO PSI MAY RESULT IN ADDITIONAL SYSTEM DEVICE COSTS AND/OR A B C D E F G H I J K L M N O P Q W a <br /> PROGRAMMING CHARGES. p <br /> 7. ALL DEVICES CONTAINING END-OF-LINE RESISTORS SHALL BE CLEARLY LABELED. 'THE EXISTING SEQUENCE OF OPERATION WILL BE FIELD VERIFY <br /> 8. WHEN APPLICABLE,SERIAL NUMBERS(BARCODE LABELS)FROM INSTALLED DEVICES SHALL BE ATTACHED TO EITHER THE <br /> REDLINED DRAWING SET OR THE SUPPLIED BARCODE WORKSHEET. <br /> 9. ANY DEVIATION FROM DESIGN MUST BE INDICATED ON PERFORMANCE SYSTEMS INTEGRATION,LLC(PSI)SHOP DRAWINGS <br /> AND RETURNED TO PSI UPON COMPLETION OF THE JOB. <br /> WIRE TAG SCHEDULE VICINITY MAP DEVICE LEGEND INDICATION W <br /> 12 AWG PAIR <br /> 14 AWG PAIR BD[hSY3W Both St SW INITIATING CIRCUIT LEGEND <br /> 16 AWG PAIR Science Resarce Center <br /> MC <br /> 18 AWG PAIR DRAWN BY : <br /> FPLR OR FPLP AS REQUIRED 0 SIGNALING LINE# CHECKED BY :MB <br /> SHIELDED ' DEVICE TYPE(MODULE/SENSOR) <br /> Morgan Aero ProductsDATE :03/28/2023 <br /> CABLE DEVICE SYMBOL <br /> DEVICE ADDRESS# PROJECT NUMBER:--- <br /> SIGNAL LINE CIRCUIT SLC Interlock Industries Fr�-- PERMIT NUMBER :--- <br /> CONVENTIONAL INITIATING DEVICE CIRCUIT(IDC) Q MIS## <br /> ZONE INPUT <br /> RELAY OUTPUT SHEET TITLE <br /> NOTIFICATION APPLIANCE CIRCUIT NAC <br /> BIMATERIALS, <br /> MATRIX AND GENERAL INFO <br /> REMOTE ANNUNCIATOR 24VDC POWER NOTIFICATION CIRCUIT LEGEND <br /> REMOTE ANNUNCIATOR RS485 DATA <br /> Compendium Inc <br /> AUXILIARY RS232 DATA W E <br /> SPEAKER RISER QValenceSurface Q PANEL# <br /> SPEAKER CIRCUIT Technologies <br /> DOOR HOLDER CIRCUIT DEVICE SYMBOL CIRCUIT# <br /> AUXILIARY 24VDC POWER — �� 1 1 SHEET NO. <br /> BoerngF� 1 DEVICE# <br /> CANDELA RATING <br /> NOTES:USE CABLE RATED FOR UNDERGROUND AND/OR WET CONDITIONS AS REQUIRED. Boeing FWY 75CD #u.#-## FAO.0 <br /> FIRE ALARM CABLING CAN NEVER BE LARGER THAN 12AWG OR SMALLER THAN 18AWG. — BoeL�Fx+Y — c CEILING MOUNT <br /> __sae� <br /> NON-POWER LIMITED CIRCUITS CAN NEVER SHARE PATHWAYS WITH POWER LIMITED CIRCUITSj <br />