SYMBOL LEGEND <br /> Global Projed Values: <br /> SYMBOL DESCRIPTION Project W-1526 COMMERCE CENTER Standby Hours: 24 _ <br /> F,gCP FIRE ALARM CONTROL PANELProject ID:F-------- Alarm Mirs:� <br /> Prepared By:PSI Derating Factor: 1.5 TIM KUDELA,SET <br /> Date:3/16/2023 Voltage Drop Warning <br /> ® HORN/STROBE-WALL MOUNT r F, Threshold%: 15 NICET FIRE ALARM SYSTEMS <br /> LEVEL IV: 76863 <br /> STROBE-WALL MOUNT EXP: 6/1/2023 <br /> Panel ID.- SK-5208 Model SK-5208 Fire Alarm Control Panel Max NAC Current: 3 0 Amps <br /> (N) NEW DEVICE TO BE INSTALLED Location: TBD Volts: 24 VDC Max Panel Current: 6.0 Amps THE INFORMATION ON THIS DRAWING IS THE <br /> ORIGINAL,UNPUBLISHED WORK OF <br /> (E) EXISTING DEVICE Ckt.# Circut Name Qty Current Draw Wire AWG Ohms Per Length(ft) Actual Volts @ %Drop PERFORMANCE SYSTEMS INTEGRATION LLC. <br /> Standb Alarm 8 Type 1000 Ft_ One-Wa Ohms EOL <br /> SK-5208 SK-5208 Main Control 1 1 0.140 0.550 DISCLOSURE,REPRODUCTION,OR USE <br /> NAC-1 EXISTING 09 0 000 0.000 x12 solid 159 000 2040 150% WITHOUT THE PRIOR WRITTEN CONSENT OF <br /> J 1.59 0.00 20.40 1.50% PERFORMANCE SYSTEMS INTEGRATION LLC IS <br /> NA IXISTING L- 0.000 0.000 x12 solid PROHIBITED. <br /> WIRE TAG DESIGNATION NAc EXISTING b 0.000 0.000 x12 oad 1.59 0.00 2040 1.50% <br /> NAC-4 MAX OUT =tor 0.000 1.194 x12 Solid 1.59 0.00 20.40 1.50% <br /> ID TYPE IT CIRCUIT DESCRIPTION <br /> CIRCUIT Ault Aux Power Out =g 0000 0000 xu s=Iia � 159 0 00 2040 0 00% In <br /> N <br /> Total Standby Current(Amps0.140 1.744 Total Alarm Current Am w <br /> z SLC SIGNALING LINE CIRCUIT Standby Time In Flours 24 0.083 Alarm Time In Minutes/60 5 Mirs U)18/2 AWG-SOLID-SHEILDED Total Standb AH Re uired 3.360 0.145 Total Alarm AH Re uired U- <br /> N OT IN Of <br /> CONTRACT Total Combinetl Al Requiretl 3.51 command Shortcuts a <br /> V NAC NOTIFICATION APPLIANCE CIRCUIT <br /> 14/2 AWG-SOLID-SHIELDED Multiply By The Donating Factor 1.25 Q <br /> Minimum Battery AmpHours Required 4.38 Configure Circuits Print Page 2i <br /> W <br /> rn <br /> TABLE A.18.4.3 AVERAGE AMBIENT SOUND LEVEL ACCORDING TO LOCATION "The SK-5208 and SK-5217 limits alarm current to 95mA per zone.The SK-5208 alarm current includes 10%of system zones in w <br /> alarm,but in no case less than three zones per UL 864. U <br /> AVERAGEAMBIENT (n J <br /> Z <br /> LOCATION SOUND LEVEL(dBA) O ap <br /> o <br /> BUSINESS OCCUPANCIES 55 Q <br /> EDUCATIONAL OCCUPANCIES 45 Uob <br /> INDUSTRIAL OCCUPANCIES 80 Circuit ConfigurationPrint Circuits Detail Z cT <br /> (ID INSTITUTIONAL OCCUPANCIES 50 <br /> -1810 - at Pr Information v, <br /> / 1.4 MERCANTILE OCCUPANCIES 40 01 � <br /> u4WOMEN V MECHANICAL ROOMS 85 Project Name:526 COMMERCE CENTER Project ID:0 0 <br /> 116 15CD PIERS AND WATER-SURROUNDED STRUCTURES 40 Prepared By:PSI Date:3/16/2023 - w <br /> F1.4 V PLACES OF ASSEMBLY 55 <br /> V (N) V RESIDENTIAL OCCUPANCIES 35 Ckf.Number:NAC-4 Panel ID:SK-5208 U <br /> V 1810 (P)OFFICEMaxCurrent Amps � <br /> STORAGE OCCUPANCIES 30 Ckt.Name MAX OUT NAC C 3.0 A - =mo <br /> - } <br /> F14 125 THOROUGHFARES,HIGH-DENSITY URBAN 70 Current Draw Each Current Draw Total F <br /> (P)MEN I (Ni THOROUGHFARES,MEDIUM-DENSITY URBAN 55 Qty Device Standby Alarm Standby Alarm 2 N <br /> j 117 THOROUGHFARES,RURAL AND SUBURBAN 40 a, <br /> 4 (P)STORAGE 2 P2RL O Doo 0.054 0 000 0.108 <br /> SND 126 TOWER OCCUPANCIES 35 2 BGRL 0.000 0.043 0.000 0.086 W Z <br /> LU <br /> () UNDERGROUND STRUCTURES AND 40 rn <br /> WINDOWLESS BUILDINGS 1 DOSTING NOTIFICATION CIRCUIT 0.000 1.000 0.000 1.000 _ O <br /> VEHICLES AND VESSELS 50 Unused 0.000 0.000 0.000 0.000 d W <br /> 0.000 0.000 <br /> Totals 0.000 1.194 ¢ O <br /> <Return To Main Edit Device Database LU U <br /> � O 7 <br /> Q <br /> K W0 <br /> 4 FACP BATTERY AND VOLTAGE DROP CALCULATION U <br /> SCALE:NTS d <br /> WO <br /> o z <br /> PLAN UNIT IA • UNIT IB,IC UNIT ID,IE U <br /> NORTH <br /> PARTIAL FLOOR PLAN - FIRE ALARM DEVICE LAYOUT o W <br /> SCALE:1/8"=V-0" I� <br /> 0 4 8 16 0�000p00000 W = 5 co <br /> (IN FEET) 0000,10,1000, I Q L 1- <br /> 00000000000 00 o 1113 3 W � <br /> 000000000000 0o Z z 2 UJ0�7 <br /> 2 KEYPLAN 000000000000 °_ O � Q <br /> SCALE:NTS O�a�0�000000 O N <br /> 1aa0 > <br /> a0° 0�°�0�aCc D um ¢ _ <br /> ® ® ® W <br /> It �O ~ <br /> FI, Q0 00 LL1 <br /> - <br /> LLI C/' o w <br /> (No <br /> -TO NEXT >_ a > <br /> FROM NACDEVICE OR EOL a c/) L LLI <br /> FROM NAC+ (7 +TO NEXT <br /> DEVICE OR EOL m <br /> OD � <br /> 5 <br /> P2RL HORN/STROBE AND SGRL STROBE WIRING DETAIL 04 <br /> M W <br /> SCALE:NTS N <br /> a � <br /> 0 <br /> 0 <br /> NOT WITHIN 6 IN OF CEILING <br /> v <br /> BIN Z <br /> � <br /> w <br /> V V 1510 O V 1810 V V -.',' ~ fA <br /> FIRE ALARM CONTROL PANEL or FIRE a F- <br /> Ui ,5 , STROBE(G4/G1-SERIES) <br /> ALARM REMOTE ANNUNCIATOR <br /> (E) IN F� V of <br /> (N) (SEE MANUFACTURER'S SPECIFICATION I) <br /> SHEET) W LU <br /> V <br /> D <br /> TO EXISTING <br /> NOTIFICATION DEVICES TOP OF CONTROL DISPLAY TOP OF NAC POWER SUPPLY <br /> NOT TO EXCEED 60 IN A.F.F. <br /> V REF.ADA <br /> TO EXISTING <br /> NOTIFICATION DEVICES <br /> Z v 60 IN MANUAL PULL STATION <br /> TO EXISTING TO EXISTING <br /> INITIATING DEVICES NOTIFICATION DEVICES LU i <br /> BOTTOM OF ANY CONTROL 80-96 IN D=' <br /> TO MONITORING FACP DISPLAY NOT BELOW 36 IN TOP OF BOX SUGGESTED MAX.72 IN <br /> STATION <br /> (E) A.F.F. REF.ADA <br /> FIELD VERIFY <br /> EXACT LOCATION MIN.3-1/2 FT.-MAX.4 FT. <br /> DRAWN BY MC <br /> 36 IN CHECKED BY :MB <br /> DATE :03/28/2023 <br /> PROJECT NUMBER'--- <br /> PERMIT NUMBER <br /> PARTIAL RISER DIAGRAM ELEVATION NOTES: FLOOR OPERATING HANDLE TO FLOOR MOUNT ITOPN ACO F DEVICE TO FLOOR ESS BLE LOCATION LENS TO FLOOR SHEET TITLE <br /> 3 SCALE:NTS THIS DETAIL IS NOT DRAWN TO SCALE.SEE SPECIFIC DEVICE <br /> INSTALLATION SHEETS FOR MOUNTING HEIGHT OF BACK BOX. PARTIAL FLOOR PLAN, <br /> PARTIAL RISER DIAGRAM, <br /> THE BOTTOM OR TOP OF INSTALLED DEVICE MAY NOT CORRESPOND TO CALCULATIONS AND <br /> INSTALLED BOX. <br /> DEVICE DETAILS <br /> C6TYPICAL DEVICE MOUNTING HEIGHT SHEET NO. <br /> SCALE NTS FA 1 .01 <br />